APC MGE Galaxy 3500 30 kVA Tower UPS


Price:
Sale price$16,084.00

Description

APC MGE Galaxy 3500 30 kVA Tower UPS

The APC MGE Galaxy 3500 30 kVA Tower UPS delivers centralized 3-phase power protection with the trusted reliability of the MGE family. Designed for commercial and technical facilities as well as demanding industrial environments, this UPS combines dual-mains input, automatic and maintenance bypasses, and scalable runtimes to safeguard critical equipment, maintain uptime, and protect data integrity. Its tower configuration provides a flexible footprint for data centers, server rooms, manufacturing floors, and telecom installations, offering robust power protection without sacrificing floor space. With a focus on availability, protection, and total cost of ownership, the Galaxy 3500 is engineered to support high-demand loads while simplifying maintenance and serviceability for facilities teams and technicians alike.

  • Three-phase online power protection for critical loads: The Galaxy 3500 operates in online, double-conversion mode to deliver a clean, stable sine-wave output regardless of input disturbances. This design minimizes voltage sags, surges, flicker, and harmonic distortion, protecting sensitive servers, controllers, drives, and network equipment. Its scalable runtime and hot-swappable battery modules enable you to extend protection during outages or maintenance windows without disrupting operations, ensuring business continuity even during power events or grid fluctuations.
  • High availability through dual-mains input and bypass options: With dual-mains input, the Galaxy 3500 reduces the risk of a single point of failure in your power feed. Automatic and maintenance bypasses enable seamless maintenance and service without interrupting critical loads, providing a reliable path for power during electrician work or component replacement. This feature is especially valuable in data centers, medical facilities, and industrial processes that demand continuous operation and rapid recovery from power disturbances.
  • Scalability and modular runtime: The Galaxy 3500 is built to grow with your facility. It supports expandable battery options and external battery cabinets, allowing you to tailor runtime to match your load profile and outage tolerance. The modular design simplifies battery replacements and upgrades, enabling you to scale protection as equipment and demand increase while minimizing downtime and total cost of ownership.
  • Intelligent monitoring and straightforward manageability: The system delivers built-in diagnostics and a range of management options to keep critical systems visible and healthy. Front-panel navigation, combined with remote monitoring capabilities via compatible networks, enables real-time visibility into load levels, battery health, voltage quality, and uptime. Alerts and event logging facilitate proactive maintenance, rapid incident response, and improved service levels for IT and facilities teams.
  • Rugged, adaptable deployment for diverse environments: The Galaxy 3500’s tower form factor fits a wide range of installations—from compact data centers to industrial plants and telecom rooms. Its durable construction, efficient cooling, and quiet operation make it suitable for office-adjacent spaces as well as harsh environments. The UPS integrates smoothly with existing power distribution, is easy to service, and supports flexible placement to optimize airflow and accessibility for routine maintenance.

Technical Details of APC MGE Galaxy 3500 30 kVA Tower UPS

  • Power rating: 30 kVA / 24 kW (0.8 power factor)
  • Topology: Online, double-conversion, three-phase UPS
  • Input configuration: Dual-mains 3-phase input; wide voltage window; compatible with standard 400/415 VAC utility supplies
  • Output configuration: 3-phase output; configurable voltage (typical 400/415 VAC); 50/60 Hz selectable
  • Bypass options: Automatic bypass and maintenance bypass for uninterrupted service during maintenance or load transfers
  • Battery and runtime: Hot-swappable modular battery banks; expandable runtime with external battery cabinets
  • Monitoring and management: Integrated diagnostics with front-panel display; supports remote monitoring via network interfaces and compatible software
  • Physical form: Tower footprint designed for floor- or rack-adjacent deployment; adaptable to various room layouts
  • Protection features: Built-in protection against transients, harmonics, and disturbances; enhanced fault detection and alarms for proactive maintenance

how to install APC MGE Galaxy 3500 30 kVA Tower UPS

Installing a three-phase UPS of this class should be performed by qualified electrical professionals. The following guidelines provide a high-level overview to help you plan and prepare for installation, with site-specific wiring to be completed by licensed electricians in accordance with local codes and manufacturer instructions.

  • Site selection and preparation: Choose a clean, ventilated, and level location with ample clearance for service access, battery modules, and any external cabinets. Ensure adequate cooling and protection from heat, moisture, and dust. Verify floor strength and vibration limits, and plan for unobstructed routing of input and output connections.
  • Unpacking and inspection: Inspect the unit for transit damage, verify serial numbers, and confirm that all components (including any optional batteries or external cabinets) are present. Store packing materials until installation is complete and all checks are finished.
  • Electrical connections and grounding: Have a licensed electrician connect the dual-mains 3-phase inputs per the local electrical code, with proper grounding and bond. Route input cables to dedicated electrical feeds and ensure separation from data and comms lines to minimize interference. Connect UPS output to the distribution panels serving critical loads, and configure bypass routing as defined by the site requirements.
  • Battery integration and runtime planning: Install hot-swappable battery modules or external battery cabinets according to the manufacturer’s guidelines. Verify battery health, proper interlocks, and secure connections. Use runtime charts to align battery capacity with the critical-load profile and establish desired outages tolerances.
  • System commissioning and monitoring: Power up the unit and run the built-in self-test procedures. Configure voltage, frequency, and communication interfaces, then enable remote monitoring or management software. Verify alarm behavior, bypass operation, and load transfer during test events, and document the configuration for ongoing maintenance.

Frequently asked questions

  • What is the APC MGE Galaxy 3500 30 kVA Tower UPS best for?

    It is ideal for commercial facilities, technical rooms, data centers, laboratories, and industrial environments that require reliable centralized three-phase power protection for critical loads.

  • Does it support dual-mains input?

    Yes. Dual-mains input enhances availability by providing redundancy in the power feed and enabling seamless maintenance bypass without interrupting protected loads.

  • Can runtime be expanded?

    Absolutely. Runtime is scalable through modular battery banks and external battery cabinets, allowing you to tailor protection to your specific outage tolerance.

  • How is the UPS managed and monitored?

    The Galaxy 3500 includes built-in diagnostics and supports remote monitoring via standard interfaces. It can integrate with network management systems and monitoring software to provide real-time health, load, and alarm data.

  • Is this UPS suitable for industrial environments?

    Yes. Its rugged tower design, robust electrical protection, and flexible deployment options make it well-suited for manufacturing floors, control rooms, and telecom facilities where uptime and power quality are essential.