Description
In modern data centers, clean, reliable power distribution is the backbone of uptime. The APC NetShelter Basic Rack PDU is engineered to deliver straightforward, robust power within APC NetShelter enclosures, making it an ideal foundation for high-density server racks and critical IT infrastructure. Designed for 208V operation with a 30A maximum input, this PDU provides four IEC 60320 C19 outlets to support contemporary servers, storage devices, switches, and other power-hungry equipment. Its 1U horizontal mounting footprint ensures efficient use of rack space while maintaining easy access to outlets for quick maintenance. With a 12-foot cord ending in a NEMA L6-30P plug, this unit pairs seamlessly with common data-center power circuits, enabling flexible placement and reducing cable clutter in busy racks. Whether you’re outfitting a new rack or upgrading an existing installation, the NetShelter Basic Rack PDU offers a reliable, no-fuss power distribution solution that helps you keep critical workloads online and performing at their best.
- High-capacity power distribution for dense IT environments: This PDU supports 208V operation at up to 30A, delivering reliable power to four IEC 60320 C19 outlets. Designed to handle the power needs of modern servers, storage appliances, and networking gear, the four outlets provide enough ports to power critical equipment without overcrowding the strip. The 208V/30A specification aligns with common data-center power provisioning, ensuring compatibility with enterprise-grade hardware and reducing the need for multiple distribution blocks. By concentrating power in a compact 1U footprint, it helps maximize rack efficiency while maintaining accessible outlets for easy maintenance and replacements.
- Flexible mounting for 0U and 1U configurations: The NetShelter Basic Rack PDU offers adaptable mounting options suitable for a wide range of rack layouts. At 1U height, it fits neatly into standard 19-inch racks alongside servers and network devices, allowing clean cable organization and minimal obstruction to airflow. The 0U compatibility is especially valuable for front- or rear-mumping scenarios where space is at a premium or where administrators want to optimize the vertical rack footprint. This flexibility makes it an excellent choice for both new builds and gradual upgrades in established data centers.
- Rugged, purpose-built reliability for data centers and IT closets: Built with a sturdy metal chassis, this PDU is engineered to endure the rigors of busy rack environments. The robust construction helps resist wear from frequent cable movement, accidental bumps, and the daily rhythm of data-center operations. With four high-quality C19 outlets, it provides dependable connections for critical devices while helping to maintain an organized, neatly managed power tray inside the enclosure. The design prioritizes reliability and longevity, reducing maintenance overhead and downtime due to power distribution issues.
- Secure, standards-based power connections: The 12-foot power cord terminates in a NEMA L6-30P plug, a widely used connector for 208V, 30A data-center circuits. The locking nature of the L6-30P plug helps prevent accidental disconnection in busy cabinet spaces, supporting consistent power delivery to critical equipment. This configuration supports clean, stable power delivery for servers, SANs, switches, and other rack-mounted devices, helping to minimize power disturbances that can impact performance or lead to unexpected reboots.
- Simple integration, quick deployment, and easy maintenance: The NetShelter Basic Rack PDU is designed for straightforward installation and trouble-free ongoing use. Its 1U (and 0U) mounting capability makes it compatible with most NetShelter enclosures, while the front-access outlets simplify port labeling and device identification. The 12-foot cord length provides flexibility in placement and reduces the need for excessive cabling, which in turn improves airflow and simplifies cable management. For IT teams, this PDU delivers predictable power distribution with minimal setup time, enabling faster project completion and easier day-to-day operations.
Technical Details of APC NetShelter Basic Rack PDU
- Voltage: 208V
- Current rating: 30A
- Outlets: 4 x IEC 60320 C19
- Cord: 12 ft, NEMA L6-30P
- Mounting: 0U/1U horizontal
How to install APC NetShelter Basic Rack PDU
- Power down equipment and unplug devices that will be connected to the PDU, if necessary, to ensure a safe installation environment.
- Determine the optimal mounting position within the APC NetShelter enclosure. Decide whether you will use 1U horizontal mounting or 0U mounting at the base, depending on your rack layout and cable management strategy.
- Secure the PDU to the rack rails using the appropriate mounting hardware provided with the unit or recommended by APC for 0U/1U installations. Ensure the PDU is firmly mounted and level to prevent outlet misalignment or cable strain.
- Route the 12-foot power cord to a suitable 208V, 30A power source. Keep the cord away from high-traffic areas and sharp edges, and use cable ties or Velcro straps to create a clean, organized path that does not restrict airflow.
- Connect each device to the four IEC 60320 C19 outlets, distributing load across outlets to stay within the 30A rating. Label the outlets if needed for easier future maintenance. Power on equipment and verify that all devices receive stable power and operate normally. Periodically inspect cable management and outlet connections to ensure ongoing reliability and safety.
Frequently asked questions
- Q: What outlets does this PDU provide? A: Four IEC 60320 C19 outlets.
- Q: What is the input voltage and current rating? A: 208V at up to 30A.
- Q: What mounting options are available? A: 0U or 1U horizontal mounting to fit most APC NetShelter enclosures.
- Q: What plug type is supplied with the cord? A: NEMA L6-30P plug on a 12-foot cord.
- Q: Is this compatible with other brands of racks or only APC NetShelter enclosures? A: It is designed for use within APC NetShelter enclosures, offering seamless integration and optimized form factor for APC racks, though it can be used in compatible 19-inch rack environments with appropriate mounting accommodations.