APC NetShelter Basic Rack PDU, Zero U, 16A, 230V, 20 C13 and 4 C19 outlet, IEC C20 inlet


Price:
Sale price$500.83

Description

The APC NetShelter Basic Rack PDU is a space-saving, high-efficiency power distribution unit designed to simplify power management in tight data center and IT closet environments. Built for reliability and flexibility, this Zero U vertical PDU delivers centralized power distribution to a wide range of IT equipment while preserving valuable rack space. With a robust 16A input at 230V and a total of 24 outlets (20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets), it provides the versatility you need to support everything from servers and storage to networking gear and KVM consoles. A 10-foot power cord with IEC C20 inlet ensures convenient, scalable wiring, enabling clean layouts and easy installation in most APC NetShelter racks and similar enclosures.

  • Zero U vertical mounting design offers a compact footprint that maximizes rack space for equipment placement and airflow, reducing cable clutter and improving cooling efficiency.
  • 24 outlets for flexible equipment connections includes 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets, accommodating a broad mix of servers, storage arrays, switches, and peripherals.
  • 230V operation at up to 16A provides dependable, standards-compliant power distribution for mid-density racks and enterprise IT environments.
  • 10-foot power cord with IEC C20 inlet supports convenient reach and clean power routing from wall outlets or power distribution configurations, while the C20 inlet on the PDU accepts compatible power cords for safe, secure connections.
  • Sturdy, maintenance-friendly design built to withstand rigorous data center use, with straightforward installation, reliable performance, and easy cable management for long-term reliability.

Technical Details of APC NetShelter Basic Rack PDU

  • Model overview: APC NetShelter Basic Rack PDU, Zero U vertical rack-mount style for space-efficient power distribution.
  • Input voltage and current: 230V AC, up to 16A maximum input current for reliable support of mid-density IT loads.
  • Outlets: 20 IEC 60320 C13 outlets plus 4 IEC 60320 C19 outlets, totaling 24 power receptacles to accommodate a variety of devices.
  • Inlet and cord: IEC C20 inlet on the PDU; comes with a 10-foot power cord to connect to the facility power source.
  • Mounting type: Zero U vertical mounting design to maximize rack depth for equipment and ensure optimal airflow within the enclosure.
  • Length and compatibility: Designed for compatibility with APC NetShelter enclosures and similar 19-inch racks that support vertical PDUs and zero-U configurations.
  • Applications: Ideal for data centers, server rooms, network closets, and space-constrained IT environments where reliable power distribution and tidy cable management are essential.

How to install APC NetShelter Basic Rack PDU

Installing the APC NetShelter Basic Rack PDU is a straightforward process designed to minimize downtime and maximize space efficiency. Follow these general steps to ensure a safe and effective setup in most standard 19-inch racks:

  • Prepare the installation area: Power down and unplug equipment as necessary. Verify that the data center or IT closet has a stable 230V supply capable of supporting up to 16A on the PDU’s circuit.
  • Position the PDU in the rack: With its Zero U vertical mounting design, slide the PDU into the rack rail space along the side or back rail area, aligning with the rack holes for secure attachment.
  • Attach mounting hardware: Use the included mounting hardware or the rack manufacturer’s compatible fasteners to securely fix the PDU in place. Ensure the unit is level and stable to prevent cable strain.
  • Connect the power cord: Route the 10-foot power cord from the PDU’s IEC C20 inlet to a compatible 230V power source. Ensure the cord path minimizes obstruction and maintains proper clearance for airflow.
  • Organize and connect outlets: Beginning with the most critical or high-priority devices, connect equipment to the 20 C13 outlets and 4 C19 outlets as needed. Use cable ties or velcro straps to bundle cords and reduce clutter, promoting improved airflow and easier maintenance.
  • Test and verify: Power on the rack and verify that all connected devices receive power. Check for audible indicators or LED status (as applicable) and confirm that load distribution remains within the 16A limit.
  • Document wiring and labeling: Clearly label each outlet with the connected equipment to facilitate future maintenance, power audits, or equipment replacements. Maintain an up-to-date rack layout for quick reference.

Frequently asked questions

  • Q: What does Zero U mean in this PDU? A: Zero U refers to the slim, vertical mounting design that sits flush with the rack’s front or back rail, preserving horizontal space for equipment while delivering full power distribution.
  • Q: How many outlets does this PDU have and what types? A: It features 24 outlets in total—20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets—ideal for a mix of servers, storage, and network devices.
  • Q: What voltage and current does it support? A: The unit operates at 230V and is rated for up to 16A maximum input current, suitable for mid-density racks in standard data centers.
  • Q: What is the length of the power cord? A: The PDU ships with a 10-foot power cord, providing flexible routing within the rack and surrounding room.
  • Q: What inlet type does the PDU have? A: The PDU includes an IEC C20 inlet, compatible with C19 power cords and APC-compatible configurations for secure power connections.