Description
Elevate your data-center power management with the APC NetShelter Metered-by-Outlet with Switching Rack PDU. Built for reliability in demanding environments, this 0U rack-mountable power distribution unit delivers granular, per-outlet metering and remote control to optimize uptime, energy efficiency, and cost visibility. With 21 C13 outlets and 3 C19 outlets, it supports a diverse mix of servers, storage, and networking gear while preserving valuable rack space. Ideal for virtualization clusters, data centers, and lab environments, it helps you track usage, manage power budgets, and respond quickly to faults without sacrificing overall rack performance.
- Metered-by-Outlet with Switching: Each outlet reports real-time energy usage and can be turned on or off remotely to reboot locked-up equipment or recycle power without interrupting other devices. This precise control enables proactive load management, faster fault isolation, and better capacity planning for growing data centers. It also supports energy-optimization initiatives by providing detailed per-outlet consumption data that can be used for charge-back, budgeting, and efficiency reporting.
- Compact 0U Rack-Mount Design: Designed to fit in a standard 19-inch rack without adding vertical footprint, the unit keeps densities high and airflow unobstructed. Its rugged metal construction and integrated cable-management channels help maintain a clean, organized environment while simplifying installation and ongoing maintenance. The 0U profile frees up valuable rack space for other critical equipment and upgrade paths.
- High-Density Outlet Configuration: A versatile mix of 21 C13 outlets and 3 C19 outlets supports a broad range of equipment—from blade servers to storage controllers and network gear—reducing the need for multiple PDUs and easing cable management in tight racks. The outlet arrangement enables strategic power distribution to essential devices while leaving space for growth and future hardware.
- Two-Voltage Compatibility: Supports 208V up to 20A and 230V up to 16A, enabling deployment across global facilities with different electrical standards while preserving power budgets and minimizing compatibility risk for critical workloads. This flexibility is ideal for multinational data centers, labs, and edge deployments where electrical codes vary by region.
- Remote Management and Security: Centralized control through APC management tools delivers per-outlet metering data, secure user authentication, and configurable permissions. You can monitor energy trends, receive alerts, and control outlets remotely to improve uptime without exposing your entire rack to unauthorized changes. The solution integrates with existing APC ecosystems to support scalable, policy-driven management across the data center.
Technical Details of APC NetShelter Metered-by-Outlet with Switching Rack PDU
- Outlets: 21 x IEC C13 and 3 x IEC C19 outlets for versatile power distribution to mixed equipment.
- Footprint: 0U rack-mount design suitable for standard 19-inch racks, preserving vertical space for other devices.
- Electrical configuration: 208V at up to 20A and 230V at up to 16A, providing flexibility to align with regional electrical standards and facility capabilities.
- Metering: Metered-by-outlet with per-outlet energy measurement, enabling precise tracking of energy usage, trends, and potential cost allocation.
- Outlet control: Individual outlet switching for reboot and power-cycling without affecting adjacent devices, facilitating rapid fault isolation and uptime improvements.
- Management compatibility: Designed to integrate with APC management software and network interfaces, enabling centralized monitoring, alerting, and policy-based control across the data center ecosystem.
how to install APC NetShelter Metered-by-Outlet with Switching Rack PDU
- Plan the installation by confirming rack compatibility, ensuring adequate clearance for ventilation, and verifying that your rack supports a 0U PDU in the intended location.
- Mount the PDU in the rack using the provided mounting brackets or rails, making sure it is securely fastened and properly grounded to prevent electrical faults or EMI interference.
- Connect the incoming power cord to a suitable power source that matches the PDU’s electrical configuration (208V or 230V) and confirm that the circuit can safely sustain the total potential load of all outlets.
- Attach equipment power cords to the PDU outlets (21 C13 and 3 C19 as required) and, if applicable, connect a network management interface for remote monitoring and control. Configure per-outlet metering and user access permissions within the APC management environment.
- Power on the PDU, verify outlet status, test remote switching on individual outlets, and confirm that energy readings are being reported accurately. Establish alert thresholds and run a brief reboot test to ensure reliable operation during routine maintenance.
Frequently asked questions
- Q: What does Metered-by-Outlet mean? A: It means each outlet reports energy usage and can be controlled independently for precise load management and faster recovery from faults.
- Q: How many outlets does this PDU have? A: It provides 24 total outlets: 21 C13 and 3 C19, arranged in a 0U footprint suitable for standard 19-inch racks.
- Q: Can I use this PDU in both 208V and 230V environments? A: Yes, it is designed for dual-voltage configurations, supporting up to 20A at 208V and up to 16A at 230V, depending on your load and local electrical codes.
- Q: Is per-outlet monitoring included? A: Yes, each outlet provides metered data that can be collected by compatible APC management tools for energy accounting and usage reporting.
- Q: How does remote switching improve uptime? A: You can remotely cycle individual outlets to reboot a locked-up device without affecting other equipment, speeding fault isolation and reducing downtime.