APC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 5.7kW, 208V, 21 C13 and 3 C19 outlet


Price:
Sale price$2,957.14

Description

Upgrade your data center and IT closet power management with the APC NetShelter Metered-by-Outlet with Switching Rack PDU. This compact 0U, high-capacity power distribution unit delivers precise outlet-level metering, reliable remote switching, and granular control to optimize energy usage, improve uptime, and simplify management in tight rack spaces. Designed for APC NetShelter enclosures and compatible IT deployments, it helps you monitor, manage, and protect critical equipment—from servers and switches to storage devices and PDUs—while supporting efficient reboot cycles and power recycling to keep systems responsive and available.

  • Power metering at the outlet level with real-time energy usage data for each connected device, enabling accurate cost allocation, capacity planning, and energy optimization across your entire rack footprint.
  • Remote outlet switching provides on/off control for individual outlets, enabling safe reboot cycles, proactive problem resolution, and automated power-cycling routines to restore service without manual intervention.
  • Metered-by-Outlet with Switching combines visibility and control in a single, space-saving 0U unit, delivering seventeen-plus essential performance attributes in a compact form factor suitable for dense racks.
  • Rack-ready design featuring 21 C13 outlets and 3 C19 outlets supports mixed power needs for modern IT gear, networking gear, and storage devices while preserving orderly cable management and airflow.
  • Robust safety and reliability with overload protection, surge protection, and ENERGY-STAR-aligned power management features that integrate with DCIM tools and monitoring platforms for centralized governance.

Technical Details of APC NetShelter Metered-by-Outlet with Switching Rack PDU, 2G, 0U, 5.7kW, 208V, 21 C13 and 3 C19 outlet

Specifications are provided to help IT teams plan deployments and ensure compatibility with APC NetShelter environments and 208V infrastructure. This section highlights the core capabilities that make this PDU a strong fit for data center, server room, and network closet deployments. The model is designed to deliver reliable power distribution while enabling precise metering and controlled reboot capabilities for improved uptime.

  • Model type: Metered-by-Outlet Switching Rack PDU (2G) for APC NetShelter enclosures
  • Input voltage: 208V nominal
  • Total power capacity: 5.7 kW
  • Outlet configuration: 21 × IEC C13 outlets and 3 × IEC C19 outlets
  • Mounting: 0U footprint to maximize rack space efficiency
  • Outage control: Remote outlet switching with per-outlet control for reboot and maintenance cycles
  • Metering: Per-outlet energy monitoring to track consumption, detect anomalies, and support chargeback and sustainability reporting
  • Protection features: Overload protection, surge protection, and built-in safety mechanisms for reliable operation
  • Management options: Local and remote management capabilities to integrate with DCIM tools and monitoring platforms

how to install APC NetShelter Metered-by-Outlet with Switching Rack PDU

  • Prepare the APC NetShelter rack and identify the lowest available 19-inch mounting space to install the 0U PDU, following the enclosure’s installation guide and safety procedures.
  • Connect the PDU input to a 208V power source that matches the unit’s electrical requirements, ensuring the circuit is protected with appropriate breakers and wiring per local code.
  • Mount the PDU securely in the rack, route cables cleanly to preserve airflow, and avoid blocking any air intakes or exhaust paths around the devices connected to the PDU outlets.
  • Connect IT equipment to the 21 C13 outlets and 3 C19 outlets, distributing devices to balance load and prevent overloading any single outlet bank.
  • Configure outlet metering and remote switching through the PDU’s onboard interface or integrated management software; set up on/off schedules, alert thresholds, and firmware updates as needed for proactive management.
  • Test the system by performing a controlled power cycle on selected outlets to verify proper reboot behavior and ensure other devices remain unaffected during the process.

Frequently asked questions

  • Q: What does Metered-by-Outlet mean? A: It means the PDU provides energy metering data for each individual outlet, allowing you to measure power usage per device rather than just total rack consumption.
  • Q: How can I reboot devices remotely? A: Each outlet can be turned on or off remotely, enabling controlled reboots of stuck equipment without needing to access the device directly.
  • Q: What outlets are available on this PDU? A: The unit includes 21 IEC C13 outlets and 3 IEC C19 outlets, suitable for a mix of servers, switches, and other IT gear.
  • Q: Is this compatible with APC NetShelter enclosures? A: Yes, this PDU is designed for convenient integration within APC NetShelter enclosures and similar rack setups.
  • Q: Can the PDU integrate with DCIM tooling? A: Yes, its management and metering data can be leveraged by DCIM platforms and remote monitoring solutions for centralized control.
  • Q: What is the main benefit of outlet-level metering? A: It enables precise energy tracking, supports capacity planning, helps with chargeback and sustainability reporting, and informs energy-saving strategies at the device level.
  • Q: Does the PDU offer surge protection? A: Yes, it provides surge and overload protection to enhance equipment safety and reliability.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed