APC NetShelter Metered Rack PDU, 2G, 0U, 15A, 100-120V, 10 NEMA 5-15R outlets


Price:
Sale price$923.71

Description

Designed for high-density data centers and server rooms, the APC NetShelter Metered Rack PDU delivers precise energy measurement, proactive protection, and scalable power distribution for critical IT equipment. This metered PDU (2G, 0U) fits standard 19-inch racks and provides reliable, granular visibility into how your devices draw power, helping you optimize energy use, manage costs, and protect circuits from overloads. With 10 NEMA 5-15R outlets, a compact 0U footprint, and a 15A, 100-120V power rating, it’s a compact, powerful solution for modern data center environments that demand efficiency without sacrificing reliability.

  • Active metering and energy optimization: The NetShelter Metered Rack PDU continuously measures power usage at the outlet and total levels. Real-time energy data helps IT teams identify under- or over-utilized circuits, optimize workload placement, and drive cost savings. With per-outlet and total power metrics, you can pinpoint which devices drive consumption and implement targeted efficiency initiatives, ultimately improving data center ROI.
  • User-defined alarm thresholds and real-time alerts: Stay ahead of potential issues with customizable alarm thresholds. The PDU raises local alarms and supports remote alerts to warning systems, letting facilities and IT staff respond quickly to nearing circuit overloads. This proactive approach reduces downtime risk and protects sensitive equipment from power-related problems, enhancing overall data-center reliability.
  • Compact 0U, rack-mount form factor: Engineered for space-constrained environments, the 0U footprint fits seamlessly in 19-inch racks without consuming valuable rack space. The slim profile keeps power distribution close to the equipment it serves, delivering clean cable management and easy access to outlets while maintaining ample clearance for airflow and maintenance.
  • Durable, mission-critical design for APC NetShelter deployments: Built to endure the rigors of data center operation, this PDU complements APC NetShelter enclosures and other traditional 19-inch racks. The rugged construction supports continuous operation under demanding load conditions, and the simple mounting hardware makes installation straightforward for data-center technicians and facilities teams alike.
  • Comprehensive power utilization data for smarter decisions: Beyond simply delivering outlets, the Metered Rack PDU captures and reports power usage trends, aiding capacity planning and energy reporting. IT managers can leverage this data for audits, sustainability reporting, and ongoing optimization of IT infrastructure, aligning power consumption with business growth and IT strategy.

Technical Details of APC NetShelter Metered Rack PDU, 2G, 0U, 15A, 100-120V, 10 NEMA 5-15R outlets

  • Voltage: 100–120V
  • Current rating: 15A
  • Outlets: 10 NEMA 5-15R
  • Mounting: 0U, fits standard 19-inch racks
  • Form factor: Metered rack PDU (2G variant)
  • Metering: Active energy measurement with per-outlet and total power data
  • Alerts: User-defined alarm thresholds with local and remote notification
  • Power distribution: Dedicated, organized outlet network for IT equipment
  • Brand: APC by Schneider Electric
  • Typical use: Data centers, server rooms, network closets requiring precise energy management

How to install APC NetShelter Metered Rack PDU

Installing the APC NetShelter Metered Rack PDU is a straightforward process designed for IT staff and facilities professionals. The following steps provide a practical guide to mount, connect, and configure the 0U PDU for optimal power delivery and energy monitoring in a standard 19-inch rack environment.

1) Plan and verify compatibility: Confirm that your rack supports 0U PDUs and that the electrical circuit (100–120V, 15A) aligns with your facility’s power supply. Review your data-center’s power distribution strategy to determine whether this metered PDU should serve your critical servers, storage devices, and network equipment.

2) Prepare the rack and PDU: Inspect the rack, clean the mounting area, and prepare the mounting hardware included with the PDU. Ensure there are clear paths for cable management and adequate airflow around the unit to prevent overheating. The 0U design allows the PDU to be mounted in the rear or along the side of the rack as needed, depending on your cabling layout.

3) Mount the PDU: Align the PDU’s mounting flanges with the rack’s vertical rails and secure it using the provided screws or mounting hardware. The 0U form factor keeps the unit low-profile and unobtrusive, preserving valuable rack space for equipment while maintaining efficient power distribution to connected devices.

4) Connect power and loads: Connect the incoming power cord to a suitable 100–120V, 15A power source. Route the 10 NEMA 5-15R outlets to your IT equipment in an organized manner, using cable management accessories to minimize clutter and maximize airflow. Ensure cords are not kinked or strained and that outlet usage does not exceed the PDU’s rating.

5) Configure metering and alerts: Access the PDU’s local interface (and any remote management solutions your setup uses) to configure alarm thresholds, metering intervals, and alert destinations. Set thresholds based on typical load patterns to receive timely warnings of potential overloads. Review metering data after initial operation to validate that energy usage is being tracked accurately and that reporting aligns with your reporting requirements.

6) Validate functionality and performance: Power on connected equipment and verify that all outlets function correctly. Confirm that metering readings appear in the management interface and that alerts trigger when thresholds are approached or exceeded. Document the installation for future reference and ensure ongoing maintenance aligns with your data-center operating procedures.

Frequently asked questions

  • What is a metered PDU? A metered PDU provides active power metering and energy data for each outlet or group of outlets, enabling you to monitor consumption, optimize energy use, and protect circuits from overloads with real-time information and alarms.
  • What does 0U mean? 0U refers to the PDU’s height in the rack unit measurement. A 0U PDU sits flush with the rack’s rear space, occupying no vertical space and leaving rack units free for other equipment while still delivering power distribution to connected devices.
  • What does 2G indicate in this model? The 2G designation identifies the model variant within APC’s NetShelter Metered PDU family. It distinguishes the unit’s metering configuration and form factor. For precise feature matching, refer to APC product documentation or specifications for the exact model variant you’re using.
  • Is this PDU compatible with non-APC racks? Yes. This 0U, 19-inch rack-compatible PDU is designed to fit standard 19-inch rack cabinets and can be used in non-APC racks as long as there is suitable mounting space and clearance. Always verify mounting hardware compatibility and electrical safety requirements for your facility.
  • Can I monitor this PDU remotely? Yes. The Metered Rack PDU provides energy data and alarm information that can be integrated with remote monitoring solutions. Real-time alerts and utilization data support centralized management, capacity planning, and energy reporting across your data center.