APC NetShelter Metered Rack PDU, 2G, 0U, 17.3kW, 240V, 30 C13 and 12 C19 outlets


Price:
Sale price$2,575.84

Description

APC NetShelter Metered Rack PDU, 2G, 0U, 17.3kW, 240V, 30 C13 and 12 C19 outlets

Engineered for performance-driven data centers and high-density rack environments, the APC NetShelter Metered Rack PDU delivers active metering, reliable circuit protection, and scalable energy management. This 0U, 2G rack-mountable unit fits seamlessly into APC NetShelter cabinets, providing precise power utilization data, real-time alerts, and flexible load management. Whether you’re optimizing for energy efficiency, protecting critical IT gear, or preparing for future capacity growth, this metered PDU serves as a cornerstone of a smarter, more reliable power infrastructure.

  • Active metering for precise energy visibility: The PDU continuously measures voltage, current, power, and energy consumption at the outlet or bank level, giving you granular insight into how every device contributes to overall load. This visibility enables data-driven capacity planning, smarter purchasing decisions, and measurable reductions in energy waste across the rack and data center. By tracking real-time power patterns, you can identify underutilized loads, peak demand periods, and opportunities to balance workloads to maintain performance while lowering operating costs.
  • User-defined alarm thresholds and alerts: Set custom warning and critical thresholds to automatically warn you when loads approach limits. The system provides real-time local indicators and remote alerts to your network management tools, helping you respond quickly to potential overloads. With proactive notifications, you can prevent outages, protect sensitive equipment, and maintain service levels without constant manual monitoring.
  • High-capacity, flexible outlet configuration: With a total capacity of 17.3 kW at 240V and a mix of 30 IEC C13 outlets plus 12 IEC C19 outlets, this PDU supports a broad range of servers, storage devices, networking gear, and other critical equipment. The generous outlet allocation helps you consolidate power distribution within a single rack, reducing cable clutter and simplifying management. The metered design ensures you know exactly how much power is being drawn by each device or group of devices, so you can optimize workload placement and avoid overloads.
  • 0U footprint with 2G rack compatibility: The slim, front- or rear-mountable 0U form factor preserves valuable rack space and improves airflow, allowing for better cooling efficiency in dense deployments. Its 2G design makes it compatible with a broad range of NetShelter cabinets and other standard rack systems, enabling straightforward integration into existing infrastructure without sacrificing accessibility or serviceability.
  • Integrated energy management and protection: Built for APC NetShelter ecosystems, this metered PDU surfaces power utilization data to drive energy programs, asset management, and uptime optimization. It supports robust circuit protection and coordinated load management across multiple devices, helping you extend equipment life, reduce thermal stress, and maintain predictable performance in every rack. This combination of metering, alarms, and protection creates a comprehensive foundation for data center reliability and efficiency.

Technical Details of APC NetShelter Metered Rack PDU

  • Model: APC NetShelter Metered Rack PDU, 2G, 0U
  • Voltage: 240V
  • Maximum power: 17.3 kW
  • Current at full load: ~72 A (17.3 kW / 240 V)
  • Outlets: 30 IEC C13, 12 IEC C19
  • Form factor: 0U, 2G rack-mountable
  • Metering: Active metering with real-time power data for insight and optimization
  • Alarms: User-defined thresholds with local and remote alert capabilities
  • Protection: Built-in circuit protection and load management to safeguard connected equipment
  • Management readiness: Designed for integration with APC NetShelter management tools and common data center analytics approaches

How to install APC NetShelter Metered Rack PDU

  • Prepare the rack: Ensure the NetShelter cabinet is properly grounded and has adequate clearance for airflow and cable routing. Verify that your rack rails are compatible with the PDU’s mounting kit and that there is sufficient space behind the rack for power connections.
  • Power down equipment as needed: When possible, power down nonessential devices to simplify the initial connection and testing process. This minimizes risk while you wire the PDU to the distribution and downstream devices.
  • Mount the PDU: Attach the PDU to the rack rails using the provided mounting hardware. Confirm that the unit is securely fastened and properly aligned to avoid cable strain or interference with adjacent equipment.
  • Connect power and outlets: Connect the PDU input to the facility power source according to the manufacturer’s guidelines. Then connect your IT gear to the 30 C13 outlets and 12 C19 outlets, ensuring that the total connected load does not exceed the PDU’s 17.3 kW rating.
  • Configure metering and alerts: Use the PDU’s management interface to enable active metering, set alarm thresholds, and configure notification preferences. Validate that local indicators reflect power conditions and that remote alerts are delivered to your DCIM or network management system. Finally, test a controlled overload scenario to confirm alarms function as intended.

Frequently asked questions

  • Q: What outlets are included on this APC PDU? A: It provides 30 IEC C13 outlets and 12 IEC C19 outlets, offering flexible power delivery for a mix of servers, storage, and networking equipment within a single rack.
  • Q: Does this PDU provide energy metering? A: Yes. It features active metering to deliver real-time power usage data, enabling energy visibility, capacity planning, and efficiency improvements.
  • Q: What is the footprint of this PDU? A: It is a 0U, 2G rack-mountable unit designed to maximize rack space while maintaining accessibility and cooling efficiency.
  • Q: Can I set alarms and thresholds? A: Absolutely. User-defined alarm thresholds trigger both local indicators and remote alerts to warn of potential overloads or abnormal power conditions.
  • Q: Is this PDU compatible with APC NetShelter management tools? A: Yes. It is designed for seamless integration with APC NetShelter environments and supports data center management software for energy analytics and uptime optimization.