APC NetShelter Metered Rack PDU, 2G, 0U, 23.0kW, 240V, 30 C13 and 12 C19 outlets


Price:
Sale price$3,458.46

Description

The APC NetShelter Metered Rack PDU is a high-density, intelligent power distribution unit designed to power today’s data centers and IT closets with precision and reliability. Engineered for the NetShelter family, this 0U, rack-mountable solution delivers up to 23 kW at 240V across a versatile mix of outlets (30 C13 and 12 C19), giving you scalable, granular control over server racks, network hardware, and storage devices. The 2G metered design provides accurate energy measurement for load monitoring, charge-back, and energy optimization initiatives, helping IT teams reduce operating costs while maintaining peak performance. With its rugged construction and smart engineering, the PDU simplifies wiring, maximizes rack space, and supports proactive power management in demanding environments.

  • High-capacity, space-efficient power distribution: 23.0 kW total load capacity at 240V distributed across 30 C13 outlets and 12 C19 outlets, enabling safe provisioning for dense IT workloads in a single 0U footprint.
  • 2G metered power monitoring: Two groups of metering provide accurate, per-group energy data, empowering you to track power consumption, implement charge-back, and optimize cooling and capacity planning with confidence.
  • 0U rack-mount design for NetShelter environments: Engineered to install flush with standard racks, freeing up valuable rack space while maintaining easy access to cabling and outlets.
  • Versatile outlet mix for mixed equipment: A strategic blend of C13 and C19 outlets supports a wide range of servers, storage devices, and network gear, simplifying cable management and reducing clutter inside the cabinet.
  • Robust build and straightforward management: Durable enclosure designed for data-center conditions, paired with simple wiring and metering configuration to support rapid deployment and reliable operation.

Technical Details of APC NetShelter Metered Rack PDU

  • Total load capacity: 23.0 kW, 240V
  • Outlets: 30 x C13 and 12 x C19
  • Form factor: 0U rack-mountable
  • Metering: 2G metered power monitoring (two groups)
  • Product family: APC NetShelter Metered Rack PDU

How to install APC NetShelter Metered Rack PDU

Installing this PDU is a straightforward process that maximizes space efficiency and ensures reliable power delivery to critical devices. Follow these general steps to install and begin using the unit in a compatible NetShelter rack.

  • Prepare the rack: Ensure your NetShelter rack is compatible with a 0U PDU configuration and has appropriate mounting rails and clearance for cable routing.
  • Power down and plan: Power down equipment you will connect to the PDU, and map outlets to devices based on criticality and peak load. Label cords to simplify future maintenance and load balancing.
  • Mount the PDU: Position the PDU in the rear of the rack in a 0U slot. Use the included mounting hardware to secure the unit firmly to the rack rails, ensuring stability and vibration resistance in dense environments.
  • Connect input power: Connect the PDU to a 240V power source with appropriate overcurrent protection. Verify correct grounding and ensure the circuit can handle the anticipated load (up to 23 kW).
  • Route and connect outlets: Neatly route device power cords to the C13 and C19 outlets. Avoid overloading individual outlets and maintain organized cable management to promote airflow and ease maintenance.
  • Configure metering: Access the PDU’s metering and, if available, integration features through the management interface. Enable 2G metering and configure any group-specific monitoring, alert thresholds, and reporting preferences.
  • Test and validate: Power on the rack, verify that outlets energize as expected, and confirm real-time power readings through the metering interface. Run a brief load test to validate measurement accuracy and ensure balanced distribution across groups.

Frequently asked questions

  • Q: What does 2G metered mean on this PDU?
    A: 2G metering indicates two separate groups of power measurement, allowing you to monitor energy usage for different sets of outlets or devices within the same PDU. This supports more precise load reporting, cost allocation, and energy management across racks.
  • Q: How many outlets does this PDU provide, and what outlet types are included?
    A: The unit provides 42 outlets in total: 30 C13 outlets and 12 C19 outlets, all distributed across a 0U form factor designed for APC NetShelter racks. This mix accommodates a wide range of server, storage, and networking gear.
  • Q: What voltage is required for operation?
    A: The PDU operates at 240V, suitable for standard data-center power distribution and many IT environments requiring higher-voltage power distribution for efficiency and cooling optimization.
  • Q: Can this PDU be used in other APC NetShelter racks?
    A: Yes. The 0U, rack-mountable design is compatible with APC NetShelter enclosures and similar rack-mount environments, enabling seamless integration into existing infrastructure.
  • Q: What benefits does metered PDU power monitoring provide?
    A: Metering delivers real-time energy data, supports capacity planning, enables charge-back for departments or customers, helps identify power-hungry equipment, and improves overall data-center efficiency by aligning supply with demand.