Description
APC NetShelter SX 12U Server Rack Enclosure with Shock Packaging — Black
The APC NetShelter SX 12U server rack enclosure is a purpose-built solution designed for fast deployment, reliable performance, and scalable growth in data centers, edge facilities, and laboratory environments. This black, professional-grade enclosure combines rugged construction with thoughtful accessibility, enabling quick installation, efficient cable management, and dependable protection for sensitive IT equipment. Built to support modern workloads, it offers a generous mounting depth, strong load ratings, and flexible accessory options, making it an ideal foundation for racks, servers, storage arrays, switches, PDUs, and uninterruptible power supplies. The inclusion of shock packaging underscores APC’s commitment to safe transportation, ensuring that your gear arrives intact and ready for operation. Whether you’re deploying new equipment in a greenfield data center or upgrading an existing rack, the NetShelter SX is engineered to minimize downtime while delivering excellent ergonomics, security, and maintenance simplicity.
- 12U height with substantial mounting depth: The enclosure supports up to 756 mm (29.8 in) of equipment mounting depth, allowing you to house a wide range of servers, storage, networking devices, and UPS units in a single, organized enclosure. This depth accommodates enterprise-grade hardware, multi-node blades, and dense IT configurations without sacrificing airflow or accessibility. The design makes it easier to consolidate gear while maintaining safe clearance for cables, power distribution, and cooling paths, keeping your data center footprint efficient and scalable.
- Robust structure with dual 0U accessory channels: The NetShelter SX provides two 0U accessory channels that enable flexible, tool-less customization for rails, cable management arms, and other mounting hardware. This feature simplifies post-install changes, upgrades, and reconfigurations, helping preserve a clean, organized interior. With improved cable routing and front-to-back management, administrators can optimize airflow, reduce cable strain, and accelerate maintenance tasks—leading to higher overall uptime and lower operating costs.
- High load capacity for dense deployments: Designed to support up to 272 kg static and 272 kg dynamic loads, this enclosure is built to handle dense server stacks, network devices, and power distribution equipment without compromising stability or safety. The combination of a sturdy frame, secure mounting rails, and dependable paneling provides confidence when adding future equipment, expanding capacity, or reconfiguring layouts to accommodate evolving IT environments.
- Shock packaging for safe transport: The enclosure arrives with shock packaging that protects sensitive components during shipping and delivery. This thoughtful feature helps minimize the risk of dents, scratches, or misalignment that can occur in transit, ensuring that your NetShelter SX is ready for immediate installation. Shock packaging is especially valuable for distributed IT deployments, remote sites, and multi-location projects where equipment must withstand handling during transport.
- Compact, professional dimensions with secure access: Measuring 658 mm in height, 600 mm in width, and 900 mm in depth, the enclosure provides a compact yet capable footprint that fits seamlessly into data centers, telecom rooms, or controlled environments. The black finish offers a discreet, professional appearance that blends with existing infrastructure while large front and rear doors, side panels, and configurable airflow options support efficient cooling and straightforward service access for maintenance and upgrades.
Technical Details of APC NetShelter SX
- Product family: NetShelter SX server rack enclosure
- RU height: 12U
- Maximum equipment mounting depth: 756 mm (29.8 in)
- External dimensions: 658 mm (H) x 600 mm (W) x 900 mm (D)
- Weight rating: static up to 272 kg; dynamic up to 272 kg
- Accessory channels: two 0U channels
- Color: Black
- Compliance: TAA-compliant
- Front/rear door design: sealed access for security and airflow optimization
- Material and finish: sturdy steel frame with durable panels designed for long-term service
How to install APC NetShelter SX
Installing the NetShelter SX is designed to be straightforward, with an emphasis on quick setup, organized cabling, and scalable expansion. Begin by choosing a suitable location with a level floor, adequate venting, and sufficient clearance for door access, cable routing, and maintenance. Prepare the site by ensuring any required rack rails, mounting brackets, power distribution, and cooling provisions are on hand. The modular design supports front and rear access, enabling you to place equipment in convenient positions while keeping cables neatly organized. As you assemble, ensure the enclosure is plumb and stable, secure the base with appropriate fasteners, and confirm that both front and back access panels align properly for later service work. During equipment installation, plan for clean cable management—group power, data, and network runs separately, use cable ties sparingly, and route cables through the 0U channels when possible to preserve airflow and simplify future upgrades. If shock packaging was used for shipment, verify there is no residual packaging that could interfere with mounting rails or doors. Finally, perform a thorough post-install test, confirming door operation, rail alignment, and cable connectivity, and verify that airflow is unimpeded from front to back. This approach minimizes installation time while ensuring full compatibility with APC cooling solutions, power management accessories, and management software ecosystems.
- Step 1: Prepare the site—clear the space, ensure level flooring, and verify clearance for rack doors and cable pathways. Step 2: Position the enclosure and secure it to the floor or cabinet framework using manufacturer-recommended fasteners. Step 3: Install rails and accessory channels—adjust to the planned depth and align with front and rear mounting points. Step 4: Mount IT equipment—start with the heaviest components at the bottom, ensuring rails are locked, and cables are organized via the 0U channels. Step 5: Route cables—keep power and data cables separate, label each run, and use cable management arms or panels to maintain a clean, unobstructed airflow path. Step 6: Connect power and network devices, then perform a post-install check to confirm door operation, venting, and accessibility for maintenance. Step 7: Document the final layout for future upgrades and maintenance planning.
- Step 8: Test for airflow and thermal performance—validate front-to-back cooling efficiency under typical loads and adjust blanking panels as needed to prevent hot spots. Step 9: Review security and access controls—confirm that doors and panels latch securely and that any required locks or seals are in place. Step 10: Schedule routine maintenance—establish a plan for periodic checks of rails, doors, cables, and cooling components to sustain peak performance. Step 11: Consider expansion options—determine whether to add more 0U accessories channels, cabling solutions, or additional network hardware as your IT environment grows. Step 12: Maintain compliance and documentation—keep records of configurations, part numbers, and warranty details for reference and future service needs.
Frequently asked questions
- Q: What equipment can I mount in the APC NetShelter SX 12U enclosure? A: The enclosure supports up to 12U of equipment with a mounting depth of up to 756 mm, accommodating servers, storage arrays, networking gear, UPS units, and related accessories. The two 0U accessory channels provide flexible mounting options for rails, cable management, and add-ons, enabling a custom configuration that fits a range of IT needs.
- Q: How much weight can the NetShelter SX safely hold? A: It is rated for static and dynamic loads up to 272 kg each, ensuring you can deploy dense equipment configurations while maintaining stability and safety. Always distribute load evenly and anchor the enclosure per manufacturer guidelines to preserve structural integrity.
- Q: Is this enclosure compliant with Trade Agreements Act (TAA) requirements? A: Yes, the NetShelter SX is TAA-compliant, making it suitable for government procurement and projects that require TAA eligibility. This compliance supports broader deployment across regulated environments while maintaining high build quality and reliability.
- Q: What is the benefit of shock packaging? A: Shock packaging protects sensitive components during shipping and handling, reducing the risk of transit damage. This is particularly valuable for shipments to remote locations or multi-site installations where equipment experiences varying handling conditions before installation.
- Q: How does the enclosure contribute to airflow and cooling? A: The enclosure is designed to optimize front-to-back airflow, with secure doors and the option to configure blanking panels to minimize recirculation. Proper cable management and the two 0U channels support clean, unobstructed airflow paths, enhancing thermal performance and reducing hot spots in dense IT deployments.
Customer reviews
Showing - Of Reviews