APC NetShelter VX/VS Split Rear Doors


Price:
Sale price$581.47

Description

Upgrade your existing APC NetShelter VX and VS racks with the Split Rear Doors, a versatile rack accessory designed to adapt as your data center needs evolve. These doors are crafted to streamline cable management, improve airflow, and enhance access to rear components without sacrificing security or enclosure integrity. Whether you’re expanding your IT footprint, reconfiguring for new equipment, or rebalancing power and data pathways, the Split Rear Doors deliver a practical, cost-effective solution that preserves your investment in APC’s trusted NetShelter ecosystem. Built to integrate with VX and VS enclosures, they offer a modular approach to rack customization that supports dynamic workloads, evolving cabling, and tighter installation tolerances—all while maintaining the rugged durability required in data centers, telecom rooms, and server rooms.

  • Seamless compatibility with NetShelter VX/VS series: The Split Rear Doors are designed to fit APC NetShelter VX and VS rack enclosures, ensuring a precise fit with standard rear openings and mounting points. This compatibility makes retrofits straightforward, allowing you to upgrade your current enclosure without replacing the entire system. By aligning with APC’s modular philosophy, these doors preserve the rack’s structural integrity while delivering enhanced rear access for technicians and administrators.
  • Split two-door configuration for enhanced access: The distinctive split-door design divides the rear access into two panels, enabling independent operation and flexible clearance in tight spaces. This configuration simplifies cable routing, permits easier installation of cable management arms and power strips, and reduces the need to swing a single large door in cramped data centers. The result is faster maintenance, reduced downtime, and a cleaner rear cabling layout.
  • Ventilated, rack-friendly construction: Built from durable steel with a powder-coated finish, the doors maintain high airflow through the enclosure while protecting sensitive equipment. The vented design minimizes heat buildup by promoting unobstructed air movement across the rear, helping IT teams meet cooling requirements and sustain device performance. The engineering aligns with data-center best practices for energy efficiency and equipment longevity.
  • Secure, reliable hardware for durable performance: The Split Rear Doors feature robust latching mechanisms designed to withstand daily cycling in busy environments. Depending on the SKU, locking options may be available to safeguard sensitive equipment during off-hours. The dual-door approach also adds redundancy: if one door is inadvertently left ajar, the other can still provide access, reducing the risk of accidental security gaps.
  • Easy retrofit and scalable flexibility: Retrofitting existing VX/VS racks with split rear doors is a straightforward upgrade that preserves your current rails and mounting points. The doors install with standard hardware, minimizing time-to-value and avoiding disruptive data-center downtime. As your rack footprint or equipment mix changes, you can reconfigure the rear access without purchasing a new enclosure, aligning with long-term IT asset strategies and budget considerations.

Technical Details of APC NetShelter VX/VS Split Rear Doors

  • Compatibility: APC NetShelter VX and VS enclosure families; designed to fit standard rear opening dimensions found on VX/VS models.
  • Construction: Heavy-gauge steel with a durable powder-coated finish for long-lasting protection against corrosion and wear in active data-center environments.
  • Design: Split, two-panel rear doors that provide independent operation and improved access to rear cabling and components.
  • Ventilation: Ventilated rear panels to support airflow and cooling efficiency while maintaining enclosure integrity.
  • Security options: Optional locking latches or locks on each door to enhance security for sensitive equipment and reduce unauthorised access.
  • Mounting: Attaches to existing NetShelter VX/VS enclosures using standard mounting points and hardware included with the accessory kit.
  • Finish: Powder-coated black finish matched to NetShelter aesthetics and corrosion resistance requirements.
  • Weight and dimensions: Weight and dimensions vary by enclosure width/depth; designed to align precisely with standard VX/VS rear openings, ensuring a clean, flush fit.

How to Install APC NetShelter VX/VS Split Rear Doors

  • Prepare the enclosure: Power down any equipment, disconnect cables as needed, and clear the work area around the NetShelter VX/VS enclosure to provide safe clearance for door installation and removal of the existing rear panel (if present).
  • Remove existing rear door (if applicable): If your VX/VS enclosure currently has a single rear door, carefully detach it from the mounting hinges and set it aside, using the manufacturer’s guidance to avoid damage to rails or mounting points.
  • Align the split doors: Position the two rear door panels so that each aligns with its corresponding hinge column on the enclosure. Confirm that the panels sit flush against the frame and that their vented sections align with the airflow path through the enclosure.
  • Attach with hardware: Secure the split doors to the enclosure using the included mounting hardware. Tighten screws to the recommended torque without over-tightening, ensuring smooth door operation and proper alignment of both panels.
  • Connect latches and locks (if included): If your SKU includes locking hardware, install the locks or latching mechanisms on each door, ensuring smooth engagement and reliable closure. Verify that the doors latch securely and that the locking components operate without binding.
  • Verify clearance and function: Gently swing each door open and closed to confirm smooth operation without interference with rails, cabling, or airflow paths. Check cable management components to ensure cables can route behind the doors without obstruction, and verify that the rear access meets your organizational and airflow requirements.
  • Restore cabling and test: Reconnect cables, label as needed, and perform a brief functional test of connected devices to confirm proper access and airflow. Document any adjustments to cable layouts or management arms for future maintenance.

Frequently asked questions

  • Q: What is the primary benefit of using Split Rear Doors on NetShelter VX/VS enclosures? A: The split doors provide enhanced rear access, enabling easier cable management and servicing in tight spaces. They simplify routing behind the doors, improve maintenance efficiency, and help maintain consistent airflow by avoiding the need to swing a single large door in cramped rooms.
  • Q: Are these doors compatible with all VX/VS rack sizes? A: They are designed to fit the NetShelter VX and VS enclosure families and align with the rear opening dimensions used across standard VX/VS configurations. Always verify the specific enclosure width and depth to ensure a precise fit before purchasing.
  • Q: Do the Split Rear Doors affect cooling or airflow? A: No. The doors are designed with a ventilated profile to preserve rear airflow and support the enclosure’s cooling performance while still protecting equipment from dust and incidental contact.
  • Q: Can I retrofit Split Rear Doors to an existing rack? A: Yes. The doors are intended as a retrofit upgrade for compatible VX/VS racks and are installed using standard mounting points and included hardware, minimizing downtime and avoiding extensive modifications.
  • Q: Are locks or security features included? A: Some SKUs offer optional locking latches or locks for added security. Check the product variant to confirm whether locking hardware is included or available as an add-on.