APC Service Bypass Panel- 200/208/240V; 100A; MBB; Hardwire input; (6) L14-30R output


Price:
Sale price$2,131.85

Description

APC Service Bypass Panel - 200/208/240V, 100A, MBB, Hardwire Input, (6) L14-30R Output

The APC Service Bypass Panel is engineered for uptime and operational continuity, delivering a reliable bypass solution for APC InfraStruXure Type A, Smart-UPS, and Symmetra UPS products. This panel helps data centers, server rooms, and mission-critical environments perform maintenance without interrupting critical loads. Built to handle demanding workloads, it combines robust electrical design with thoughtful accessibility, enabling technicians to isolate, test, and service UPS systems with confidence while the load remains powered. With a multi-voltage input range, a 100A rating, and a hardwire input configuration, this panel is purpose-built to integrate seamlessly into enterprise power architectures, ensuring seamless transitions between maintenance mode and normal operation. Whether you're retrofitting an existing rack or deploying a new infrastructure, the APC Service Bypass Panel offers a scalable, safe, and efficient solution for keeping essential equipment online when service is required, reducing downtime and protecting critical assets.

  • Reliability at the core: Designed to support APC InfraStruXure Type A, Smart-UPS, and Symmetra configurations, this service bypass panel provides a dedicated bypass path that preserves uptime during maintenance windows. By routing the critical load through a controlled, independent path, it minimizes the risk associated with UPS maintenance or battery service, ensuring business continuity even during routine service work. The platform emphasizes robust fault isolation, rapid restoration of power, and predictable performance, making it a trusted component for data centers, telecom hubs, and other mission-critical facilities that depend on uninterrupted power. This reliability is further reinforced by a well-engineered enclosure and precise electrical connections that reduce the chance of miswiring during installation or servicing.
  • Versatile electrical compatibility: The panel supports a flexible voltage range of 200/208/240V, enabling integration with a wide variety of APC UPS models and electrical systems. With a 100A capacity, it accommodates substantial load demands while maintaining a safe margin for surge protection and short-circuit events. The hardwire input configuration simplifies integration into existing electrical distributions, allowing facility teams to tie the bypass panel directly into the building's power feeders or generator circuits. For data centers operating at different voltages, this versatility means fewer adaptation steps during deployment, faster implementation, and improved overall efficiency in power management strategies.
  • Dedicated six-output configuration for critical loads: The six L14-30R receptacles provide ample, heavy-duty outlets to connect essential equipment that must remain energized during UPS maintenance. This arrangement supports diverse device needs—from servers and network gear to cooling subsystems and environmental monitors—without requiring additional adapters or field wiring. The L14-30R outlets are known for their rugged construction and secure locking capabilities, helping ensure a stable connection in demanding environments. By consolidating critical loads onto a single, purpose-built bypass panel, facilities can streamline cable management and improve serviceability while preserving safe, organized power distribution within the rack or cabinet footprint.
  • Rugged build and safety-forward design: Built to withstand data-center environments, the APC Service Bypass Panel emphasizes a sturdy enclosure, precise alignment of bus bars, and secure terminal connections. The MBB (Main Breaker Bus) architecture enhances protection against overloads and faults, enabling rapid isolation of the bypass path when needed. Safety features include clearly labeled wiring, clear indicators, and straightforward maintenance pathways that reduce the risk of human error during installation or servicing. This emphasis on mechanical integrity, electrical safety, and fault tolerance translates into fewer outages, simpler certification processes, and a more predictable maintenance experience for technicians and facility managers alike.
  • Ease of integration, installation, and ongoing maintenance: The panel is designed to simplify service activities, minimize downtime, and support long operational lifecycles. Its modular design, compatible with APC infrastructure, enables technicians to swap or test components with minimal disruption. Clear documentation, accessible wiring routes, and compatible connector types help streamline installation, commissioning, and preventive maintenance. Additionally, the panel supports routine verification tests that confirm bypass functionality and load integrity—crucial steps in validating readiness before returning the system to normal operation. The outcome is a more efficient maintenance workflow, reduced mean time to repair, and improved facility reliability.

Technical Details of APC Service Bypass Panel

  • Product type: Service Bypass Panel
  • Voltage: 200/208/240 VAC
  • Current rating: 100 A
  • Mounting/Bus: MBB (Main Breaker Bus)
  • Input: Hardwire
  • Output: 6 x L14-30R receptacles
  • Compatibility: APC InfraStruXure Type A, Smart-UPS, Symmetra

How to install APC Service Bypass Panel

  • Prepare the installation site by ensuring adequate clearance for ventilation, access to cable routing, and appropriate mounting dimensions. Verify that the operating voltage and current requirements match the intended APC UPS configuration. Review all local electrical codes and obtain any required permits before beginning installation.
  • Power down and isolate the UPS system according to the manufacturer’s guidelines. Lockout/tagout procedures should be followed to ensure a safe work environment. Confirm that the building power is de-energized in the area where the bypass panel will be connected and that all personnel are aware of the maintenance plan.
  • Mount the Service Bypass Panel in a suitable enclosure or rack space that supports a hardwired input and the six L14-30R outlets. Align the panel with the existing electrical distribution layout and ensure sufficient space for safe wire routing, strain relief, and future service access. Securely fasten all mounting hardware and verify that the enclosure or rack provides adequate cooling for the panel and connected loads.
  • Connect the hardwired input to the building power source or to the UPS system’s input feed, following the correct wiring color codes and conductor sizes appropriate for 200/208/240V operation and 100A service. Install the main breaker on the MBB as specified by the manufacturer, ensuring proper torque on all terminations and verification of secure mechanical connections. Label the input to avoid confusion with other power sources and maintain clear, organized wiring pathways.
  • Wire the six L14-30R outputs to the designated critical loads or distribution methods, ensuring that conductor sizes and breaker protection align with local codes and the UPS’ load requirements. After wiring, double-check all terminations for tightness and correct polarity. Functionally test the bypass path by following the manufacturer’s recommended test procedure: verify that the bypass maintains power to critical equipment during the service window, monitor indicators for proper operation, and document results. Restore the system to normal operation once testing is complete and confirm that all indicators reflect healthy status.

Frequently asked questions

  • Q: What is the primary purpose of the APC Service Bypass Panel? A: It provides a dedicated bypass path for APC InfraStruXure Type A, Smart-UPS, and Symmetra UPS products, enabling maintenance and servicing without interrupting power to critical loads, thereby reducing downtime and maintaining uptime.
  • Q: What voltages does the panel support? A: The panel supports a multi-voltage input of 200/208/240V, making it compatible with a range of APC UPS configurations and electrical systems commonly used in data centers and enterprise environments.
  • Q: How much current can the panel handle? A: The unit is rated for 100A, providing ample capacity to accommodate substantial critical-load requirements while maintaining a safe operating margin for protection circuits and fault isolation.
  • Q: How many outputs are available and what type are they? A: The panel includes six L14-30R outlets, a rugged, locking-style receptacle designed for high-current applications and reliable connections to essential equipment during bypass operations.
  • Q: Is installation difficult for non-specialist technicians? A: While the panel is designed for straightforward integration with APC UPS systems, installation should be performed by qualified electricians in accordance with local electrical codes and the UPS manufacturer’s guidelines to ensure safety and proper operation.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed