APC SERVICE BYPASS PDU, 120V 15AMP W/ (8) NEMA 5-15R


Price:
Sale price$372.79

Description

APC Service Bypass PDU, a purpose-built solution for high-availability data centers, delivers reliable power distribution and streamlined UPS maintenance. Engineered for APC InfraStruXure Type A, Smart-UPS, and Symmetra systems, this 120V, 15A PDU provides a robust bypass path that keeps critical equipment powered while UPS maintenance or replacement occurs. Its front-access design and front-mount compatibility make it an ideal enhancement for dense rack deployments, where space, efficiency, and uptime are non-negotiable. With eight NEMA 5-15R outlets, it accommodates a wide range of standard data center devices—from servers and switches to storage arrays and network gear—without compromising safety or performance. This PDU is built to scale with your growing infrastructure, delivering dependable power distribution that reduces maintenance windows, minimizes downtime, and supports rapid capacity expansion. In short, it’s a smart, resilient upgrade for any data center seeking to streamline operations, improve energy efficiency, and protect vital workloads.

  • Uninterrupted maintenance capability with a dedicated service bypass path, enabling you to service the UPS without interrupting the powered loads and ensuring continuous operation of critical devices.
  • Eight NEMA 5-15R outlets provide versatile, standard 120V access points for servers, network gear, peripherals, and ancillary equipment, simplifying deployment and reducing outlet crowding in busy racks.
  • Front-access, front-mount design designed for easy installation in standard 19" racks; simplifies cable management, visibility, and hot-swapping during routine maintenance or upgrades.
  • Optimized compatibility with APC InfraStruXure Type A, Smart-UPS, and Symmetra families, delivering seamless integration with APC power environments and preserving a consistent power path for critical workloads.
  • Scalability and growth-ready construction that supports increasing load demands while maintaining high availability, helping data centers extend the lifespan of their current infrastructure and defer costly overhauls.

Technical Details of APC SERVICE BYPASS PDU, 120V 15A with (8) NEMA 5-15R

  • Receptacle Type: 8 x NEMA 5-15R outlets
  • Input Voltage: 120 VAC, 50/60 Hz
  • Current Rating: 15 A maximum
  • Power Delivery: Service bypass path with front-access outlets for routine maintenance without loading losses
  • Mounting: Rack-mountable 19" enclosure designed for front-mill placement in standard racks
  • Compatibility: Optimized for APC InfraStruXure Type A, Smart-UPS, and Symmetra UPS lines
  • Safety and Compliance: UL-listed, RoHS-compliant construction with data-center-grade reliability
  • Installation Orientation: Front-placement design to support easy access and maintenance in dense rack configurations

How to Install APC SERVICE BYPASS PDU

Step 1: Plan the deployment by confirming UPS compatibility, load requirements, and available rack space. Ensure the total connected load does not exceed the PDU’s 15 A rating and that the UPS can safely feed the PDU during bypass operations.

Step 2: Power down the UPS and connected equipment following your manufacturer’s safety procedures. Disconnect power to prevent accidental energization during installation and bypass setup.

Step 3: Mount the PDU in a suitable 19" rack or cabinet, using the recommended rails and front-mount orientation if specified. Ensure there is sufficient clearance for cables, airflow, and fault isolation during maintenance.

Step 4: Connect the PDU input to the UPS output using appropriately rated cables. Route power cords to the eight NEMA 5-15R outlets with careful cable management to minimize strain and heat buildup, keeping cords labeled for quick identification.

Step 5: Bus-load distribution should be verified by applying load gradually and checking for proper bypass operation. Restore power and perform a controlled test to confirm that the UPS can bypass load as designed while the PDU remains powered and ready for maintenance activities.

Step 6: Document the wiring schematic, outlet assignments, and bypass behavior for facilities teams. This ensures fast troubleshooting and consistent maintenance procedures across shifts and personnel.

Frequently asked questions

Q: What is the purpose of a service bypass PDU?
A: A service bypass PDU provides a dedicated bypass path that lets you service or replace the UPS without interrupting the power to connected equipment. This reduces maintenance windows and enhances availability for critical workloads.

Q: Which APC UPS families is this PDU designed to work with?
A: It is designed to be compatible with APC InfraStruXure Type A, Smart-UPS, and Symmetra UPS lines, offering a cohesive power distribution solution within APC ecosystems.

Q: How many outlets are provided and what type are they?
A: The unit provides eight NEMA 5-15R outlets, suitable for standard 120V devices commonly used in data centers and network closets.

Q: Can this PDU be mounted in any rack?
A: It is designed for standard 19" racks with front-mount accessibility. Always verify mounting brackets, clearance, and airflow in your specific cabinet before installation.

Q: What safety and compliance standards does it meet?
A: The PDU is UL-listed and RoHS-compliant, ensuring reliability and environmental responsibility suitable for data center environments.