Description
APC Smart-UPS 750VA
Protecting your critical servers, network devices, storage systems, and virtualization infrastructure starts with intelligent, reliable power protection. The APC Smart-UPS 750VA delivers network-grade battery backup that keeps essential equipment running through power interruptions and quietly guards data integrity during outages. Designed for small to medium deployments, this UPS provides clean, conditioned power, advanced battery management, and seamless integration with PowerChute Plus software to safely store data and shut down your network operating system before the battery is drained. With a flexible tower or rack-mount form factor, it fits neatly into existing IT environments, helping you minimize downtime, protect uptime commitments, and maintain service levels even when the grid flickers. Whether you’re safeguarding a single server room, a branch office, or a virtualized environment, the 750VA Smart-UPS is built to deliver dependable power protection, proactive diagnostics, and effortless management for peace of mind around every outage or spike in power demand.
- Uninterruptible power protection for critical equipment: The APC Smart-UPS 750VA is engineered to shield essential devices from power quality events, providing a reliable battery backup during brownouts, sags, and outages. This means your servers, network switches, storage devices, and VoIP gear stay online longer, reducing the risk of data loss, unplanned reboots, and degraded performance. By delivering clean, conditioned power tailored to your load, it helps preserve system integrity and uptime, even when the main power source falters. This enhanced resilience translates into fewer interruptions during critical operations, smoother maintenance windows, and improved system availability across your network.
- PowerChute Plus software for safe shutdown and smart power management: With PowerChute Plus software, the UPS integrates with your servers and operating systems to automate data protection and orderly shutdowns during extended outages. The software monitors energy usage, gracefully stores in-progress work, and triggers safe shutdown sequences to prevent data corruption. This capability is essential for servers and storage systems that demand reliable, automated responses to power events. It also provides clear event logging and helps administrators plan for capacity and battery replacement with actionable insights. In short, PowerChute Plus turns a backup device into a proactive, business-friendly safeguard for your IT environment.
- Energy-efficient AVR and reliable battery management: The Smart-UPS 750VA includes Automatic Voltage Regulation (AVR) to correct minor power fluctuations without drawing down the battery, ensuring that you get clean power for sensitive electronics without unnecessary battery use. This feature minimizes wear on the battery and extends its lifespan while maintaining stable voltage delivery to connected equipment. The battery management system performs regular self-tests and recalibrations to ensure readiness, detects degradation early, and alerts you when a battery replacement is needed. By combining AVR with proactive battery health monitoring, this UPS helps you maximize runtime when you need it and reduce maintenance surprises over time.
- Flexible connectivity and scalable management: The UPS offers versatile connectivity options, typically including USB and Serial interfaces for direct server and workstation monitoring, as well as compatibility with PowerChute Plus and management tools. This enables centralized monitoring, notification, and integration with your existing IT management stack or virtualization platforms. For networks and data centers, you can leverage these connections to remotely observe load, runtime, and battery status, enabling more informed decisions about capacity planning, maintenance windows, and asset lifecycle. The Smart-UPS 750VA is designed to work with modern IT environments, providing a dependable foundation for uptime and data protection.
- Flexible deployment and easy maintenance: With a tower or rack-mountable form factor, the 750VA unit fits a wide range of deployments—from small offices to compact data closets. Its design supports straightforward battery replacement, simple mounting, and clear status indicators to quickly convey critical conditions. Audible alarms and visual indicators help you respond rapidly to events, while the compact footprint minimizes space concerns in dense IT racks. The combination of flexible installation, accessible serviceability, and robust protection makes this UPS a practical, long-term investment for organizations seeking reliable power resilience without sacrificing valuable space or operational complexity.
Technical Details of APC Smart-UPS 750VA
- Power capacity: 750 VA / up to approximately 480 W (rating varies by model and regional version)
- Form factor: Tower and rack-mountable configuration for flexible deployment
- Output waveform: Simulated sine wave suitable for protecting most business-critical equipment
- Input voltage: Typically 120V nominal (regional variants available)
- Connectivity: USB and Serial ports for direct management; PowerChute Plus software compatibility for automated shutdowns and monitoring
- Battery type: Rechargeable sealed lead-acid (VRLA); serviceable/replaceable by trained personnel
- Protection features: Surge protection, automatic voltage regulation (AVR), and intelligent battery management with self-test
- Management and monitoring: Monitoring of load, runtime, and battery status; alerts and reporting through PowerChute Plus
how to install APC Smart-UPS 750VA
Step 1: Choose a stable installation location. Decide between a secure rack-mount position or a sturdy tower setup that allows adequate ventilation. If you’re using a rack, attach any included mounting brackets and ensure clear access to the front panel indicators and the rear power outlets.
Step 2: Position and power. Place the UPS near the devices you want to protect and connect the input power cord to a dedicated, grounded wall outlet that matches regional voltage requirements. Avoid daisy-chaining through multiple power strips to ensure accurate protection and optimal performance.
Step 3: Connect protected devices. Use the UPS’s battery-backed outlets for critical servers, switches, storage devices, and network gear. Reserve surge-only outlets for noncritical equipment to maximize runtime for essential assets during an outage. Turn on the UPS and verify that protected equipment remains powered during a simulated power interruption.
Step 4: Establish management connectivity. Connect the USB or Serial cable from the UPS to a management port on a server or workstation. Install PowerChute Plus or your preferred management software on the connected system, and configure automatic shutdown, event notifications, and energy reporting according to your IT policy.
Step 5: Run a self-test and calibrate. Use the UPS front panel or the management software to initiate a self-test. Confirm that the unit correctly detects load, reports battery health, and completes a graceful shutdown if required. Schedule regular self-tests to maintain readiness and ensure ongoing data protection.
Frequently asked questions
Q: What devices can the APC Smart-UPS 750VA protect?
A: It protects servers, network switches, storage devices, and other critical IT equipment that rely on clean, uninterrupted power. Use the battery-backed outlets for essential devices and surge-only outlets for noncritical peripherals.
Q: Does it include software for safe shutdown?
A: Yes. PowerChute Plus software is designed to monitor the UPS, coordinate safe OS shutdowns, manage power events, and provide actionable insights into battery health and runtime.
Q: Can I mount this UPS in a rack?
A: Absolutely. The Smart-UPS 750VA is designed for flexible deployment as a tower or rack-mount unit, making it suitable for a wide range of IT environments and space constraints.
Q: How does AVR benefit my equipment?
A: Automatic Voltage Regulation helps correct minor voltage fluctuations without engaging the battery, preserving battery life and delivering stable power to connected devices during minor outages or sags. This reduces wear on the battery and improves overall reliability.
Q: What should I expect in terms of runtime?
A: Runtime depends on the load connected to the UPS. Heavier loads consume more battery capacity and shorten runtime, while lighter loads extend it. Refer to the spec sheet for typical runtimes at defined load levels and plan battery replacements accordingly.
Customer reviews
Showing - Of Reviews