APC Smart-UPS SRT Input/Output Hardwire Kit, 2200VA/3000VA


Price:
Sale price$359.02

Description

The APC Smart-UPS SRT Input/Output Hardwire Kit is the essential accessory that lets you tailor your Smart-UPS to the exact demands of your power environment. Designed for the 2200VA and 3000VA Smart-UPS SRT models, this kit enables direct hardwired connections for both input power and protected loads, delivering a clean, reliable, and scalable power protection solution for data centers, server rooms, and critical infrastructure deployments. When uptime matters, this kit helps you integrate your UPS seamlessly into your building’s electrical system, enhancing safety, organization, and efficiency.

By converting to hardwired input and output, you gain the flexibility to route power exactly where you need it—whether it’s a dedicated distribution panel, a rack enclosure, or a multi-load power strip inside a equipment room. This is especially valuable in facilities with high-density equipment, tight cable management requirements, or codes that favor hardwired configurations over standard receptacles. The kit is designed to complement the Smart-UPS SRT’s advanced power protection capabilities, ensuring that critical devices stay powered and protected even during disturbances in the electrical network.

With a focus on ease of integration, the hardwire kit supports quick, professional installation and reliable operation in demanding environments. It is built to endure the rigors of data centers and industrial settings while maintaining a compact footprint that aligns with racks and utility spaces. The result is a neatly organized power pathway that reduces clutter, improves serviceability, and supports safer, code-compliant electrical connections for your UPS ecosystem.

Key benefits at a glance: enhanced installation flexibility, improved cable management, streamlined integration with building power, and continued access to the robust protection that APC Smart-UPS SRT delivers. This accessory is a practical choice for organizations looking to optimize their power architecture without sacrificing protection, efficiency, or scalability.

  • Flexible hardwire input/output enables direct wiring to building power and protected loads, replacing standard receptacle connections with a professional-grade solution.
  • Optimized for 2200VA/3000VA SRT models to ensure compatibility and reliable performance within the Smart-UPS SRT family.
  • Field-installable and user-friendly design supports quick, professional installation with clear labeling and straightforward wiring routes.
  • Rugged, data-center-grade construction built to endure demanding environments, with durable hardware and secure cable management options.
  • Safety, compliance, and reliability enhancements help align with electrical codes and best practices while preserving uninterrupted power protection for critical loads.

Technical Details of APC Smart-UPS SRT Input/Output Hardwire Kit, 2200VA/3000VA

  • Compatibility: APC Smart-UPS SRT 2200VA and 3000VA single-phase models.
  • Purpose: Input and output hardwire connections to tailor power delivery for installation in racks, rooms, or dedicated power infrastructure.
  • Kit contents: Hardwire terminal blocks, mounting hardware, wiring harnesses, and an installation guide (contents may vary by SKU).
  • Electrical considerations: Designed to accommodate standard building power configurations; follow local electrical codes and guidelines during installation.
  • Construction and standards: Built for durability in data-center environments and engineered to support reliable power protection; consult product-specific certifications and warranty terms for details.

How to install APC Smart-UPS SRT Input/Output Hardwire Kit, 2200VA/3000VA

Before you begin, ensure the UPS is powered down and disconnected from utility power. Follow all applicable safety procedures and local electrical codes. Wear appropriate personal protective equipment and, if you’re not a licensed professional, engage a qualified electrician for a hardwire installation.

Step 1 — Access and prepare: Obtain the installation manual included with the kit and identify the correct input and output terminal locations on the Smart-UPS SRT unit. Remove any access panels as required by the manual to expose the terminal blocks and mounting points.

Step 2 — Mount the kit: Align the hardwire kit’s mounting provisions with the UPS chassis. Secure the kit using the supplied hardware, ensuring that there is ample clearance for cable routing and that the assembly is firmly fastened to prevent movement during operation.

Step 3 — Connect input wiring: Connect the building power supply to the kit’s input terminals following the wiring diagram provided in the installation guide. Tighten terminal screws to the recommended torque specifications and verify that conductors are properly stripped and seated.

Step 4 — Connect output wiring: Connect the protected loads or distribution panel to the kit’s output terminals. Ensure proper grounding and bonding per local codes. Route cables neatly to minimize strain and interference, using cable management features as offered by the kit and the UPS enclosure.

Step 5 — finalize and seal: Reinstall any access panels or covers removed during installation. Verify that all connections are secure and that there are no loose wires. Restore power to the UPS and perform a manufacturer-recommended self-test to confirm the hardwired configuration is functioning correctly.

Step 6 — commissioning and validation: Use the UPS management interface to monitor input/output status and confirm that the hardwired configuration is delivering clean, uninterrupted power to the connected loads. Check for alarms or fault indicators and address any issues in accordance with the installation guide or by consulting APC support.

Tip: Keep a copy of the installation documentation with the UPS in a secure location. Proper labeling of input and output circuits improves maintenance, troubleshooting, and future upgrades, and helps ensure ongoing safety and compliance.

Frequently asked questions

Q: What is the purpose of the APC Smart-UPS SRT Input/Output Hardwire Kit?
A: It provides dedicated hardwired input and output connections for the APC Smart-UPS SRT 2200VA/3000VA units, enabling more flexible, code-compliant, and organized integration into building power and protected-load circuits.

Q: Which models are compatible with this kit?
A: The kit is designed for APC Smart-UPS SRT series units with 2200VA and 3000VA ratings. For other models, verify compatibility with APC support or product documentation.

Q: Do I need a licensed electrician to install the kit?
A: Yes. Hardwire installations involve live electrical connections and must comply with local electrical codes. A qualified electrician or trained professional should perform the installation.

Q: Will installing the kit affect my UPS warranty?
A: Warranty terms vary by product and region. Refer to the specific warranty documentation for your SKU and consult APC support if you have questions about warranty implications related to hardwire installation.

Q: Can this kit be used in data-center environments?
A: Yes. The hardwire kit is designed to support critical-load protection in data-center and server-room environments, helping improve cable management, safety, and efficiency when integrating with building power infrastructure.