APC Smart-UPS VT 30 kVA Tower UPS


Price:
Sale price$22,207.61

Description

APC Smart-UPS VT 30 kVA Tower UPS

The APC Smart-UPS VT 30 kVA Tower UPS delivers centralized, three‑phase power protection with the proven reliability of the award‑winning Smart-UPS family. Engineered for environments that demand dense power, this unit is ideal for small data centers, large retail stores, regional offices, and other networks with heavy, mission‑critical loads. It combines robust protection, scalable runtime, and intelligent monitoring in a compact tower footprint, enabling IT and facilities teams to protect critical systems without compromising space or efficiency. With dual‑mains input, advanced transfer capabilities, and industry‑leading efficiency, the Smart-UPS VT helps reduce downtime, lower operating costs, and simplify power management across multiple sites.

  • Three‑phase, centralized power protection at 30 kVA provides clean and stable power for servers, storage, network gear, and other critical equipment. This topology helps minimize voltage sags, harmonics, and transients, while offering precise voltage regulation to keep sensitive electronics operating within specifications even during utility disturbances.
  • Dual‑mains input for enhanced reliability ensures uninterrupted operation by maintaining power to critical loads during mains interruptions or fluctuations. The dual input design supports redundant feeds and improves fault tolerance for mission‑critical environments where uptime is non‑negotiable.
  • Scalable runtime with hot‑swappable batteries and optional external battery cabinets
  • provide flexible uptime. You can tailor runtime to match your load profile, perform proactive maintenance without downtime, and extend battery life with modular, field‑replaceable components that minimize mean time to repair.
  • Intelligent management and monitoring include built‑in communication options and compatibility with USB, network management cards, and DCIM tools. Real‑time analytics, proactive alerts, and detailed event logging translate to faster problem resolution and improved operational visibility across sites.
  • Flexible installation and dense footprint deliver a space‑savvy solution for modern IT rooms and retail floors. The tower design supports easy placement in rooms or cabinets, with streamlined maintenance access and scalable architecture to accommodate growing power needs without requiring a complete infrastructure rebuild.

Technical Details of APC Smart-UPS VT 30 kVA Tower UPS

  • Specifications available from the official catalog for your UPC/SKU on ec.synnex.com. Please refer to the product page for exact input/output voltages, efficiencies, dimensions, and weight.

How to install APC Smart-UPS VT 30 kVA Tower UPS

Preparing for installation starts with a careful assessment of your environment. Choose a location that provides ample airflow, stable floor support, and clearance for service access. The Smart‑UPS VT is designed for flexible deployment in either a free‑standing tower or a rack‑based configuration with appropriate mounting hardware. Prior to wiring, ensure the space meets environmental requirements such as operating temperature, humidity, and ventilation. Verify that the site has a capable three‑phase electrical service and that you have the correct mains input connectors and circuit protection in place. For systems that require dual‑mains input, confirm both feeds are routed through dedicated, properly rated disconnects and that grounding meets local electrical codes. This upfront planning reduces installation risk and accelerates the project timeline.

Step 1: Plan your layout and airflow. Position the UPS so that warm exhaust air can escape freely and not recirculate back into the intake. Maintain a minimum clearance around the device as specified in the user manual to facilitate cooling, battery access, and routine maintenance. If you are integrating into a cabinet or rack, ensure the mounting method provides secure anchoring to prevent movement during operation or servicing.

Step 2: Prepare electrical connections. Confirm the three‑phase input voltage available at the site (for example, 208 V or 400/480 V configurations) and verify that the supply can sustain the full UPS load during an event. Attach the dual‑mains input cables according to the wiring diagram supplied with the unit, using properly rated connectors and protective devices. Route cables in a way that minimizes strain and protects against accidental disconnections. If you will connect external battery cabinets to extend runtime, place them nearby in a separate, ventilated area and link them per the manufacturer’s guidance.

Step 3: Install the UPS in its chosen form factor. For a free‑standing tower, place the unit on a solid surface and ensure it is level. If you are mounting in a rack, use the appropriate rails and confirm correct alignment before securing the device. Verify that all intake and exhaust paths are clear and that no objects obstruct airflow. Confirm the presence and condition of battery modules, and check for any physical damage during shipment. If external batteries are used, verify proper electrical isolation and stepwise connection to prevent inrush or miswiring.

Step 4: Connect the protected loads and distribution. Identify critical devices (servers, storage gear, network switches, and core infrastructure) and distribute them across output phases to balance the load. Use distribution panels or cabinets that match the UPS output rating and maintain load balance to optimize voltage regulation and efficiency. Keep cabling tidy and labeled to simplify maintenance and future expansions. Ensure that safety clearances around connectors and bypass paths are preserved so that maintenance or service work can proceed without risk.

Step 5: Configure management interfaces and monitoring. Attach USB or network management cards as required by your IT strategy and connect to your existing monitoring ecosystem. Enable remote management, set alert thresholds, and configure energy metrics that matter to your organization, such as runtime at various load levels, battery health, and ambient temperature. If you use DCIM tools, integrate via SNMP or other supported protocols to receive real‑time notifications and generate actionable reports for capacity planning.

Step 6: Validate operation with a robust test plan. Power down non‑essential equipment and perform a controlled transfer test to verify that the UPS correctly handles switching to battery during an outage. Observe the output voltage stability, transfer times, and battery health indicators. Run a full self‑test sequence to confirm that all modules, fans, and indicators function as expected. Document findings, update maintenance schedules, and provide training to operators so that on‑site personnel know how to respond to alarms and perform routine battery checks.

Step 7: Document and maintain. Create a maintenance log that includes serial numbers, battery replacement dates, firmware levels, and network management settings. Establish a preventive maintenance plan with your APC partner to ensure battery health and cooling performance remain within specifications. Regularly review alarm histories and adjust thresholds to align with evolving workloads, ensuring that you preserve uptime while minimizing false alarms.

Frequently asked questions

  • Q: What is the capacity of this UPS?

    A: The APC Smart-UPS VT 30 kVA Tower UPS provides up to 30 kVA (approximately 27 kW) of three‑phase power protection for critical equipment. This capacity supports dense IT loads in small data centers and other high‑demand environments.

  • Q: What environments is it suitable for?

    A: It is ideal for small data centers, large retail stores, regional offices, and other sites with dense power requirements that demand reliable, centralized protection and streamlined management.

  • Q: Can runtime be extended?

    A: Yes. Runtime can be extended with hot‑swappable internal battery modules and optional external battery cabinets, allowing you to tailor uptime to the critical loads and service windows of your operation.

  • Q: How do I monitor and manage the UPS?

    A: Monitoring is built‑in and extensible. You can use USB or network management cards to monitor health, perform firmware updates, and integrate with your DCIM environment or enterprise monitoring tools via SNMP and other supported interfaces.

  • Q: Is the UPS energy efficient?

    A: Yes. The Smart‑UPS VT platform emphasizes high efficiency across load ranges, reducing energy consumption and heat generation while maintaining excellent power quality for critical devices.

  • Q: How should maintenance be scheduled?

    A: Schedule routine battery health checks, environmental inspections, and self‑tests as part of a preventive maintenance plan with your APC partner. Documenting battery replacement cycles and firmware updates helps sustain optimal performance over the unit’s life.


Customer reviews