APC Smart-UPS XL 3000VA Rack-mountable UPS


Price:
Sale price$1,978.48

Description

APC Smart-UPS XL 3000VA Rack-Mountable UPS

Protect your most critical equipment with the trusted APC Smart-UPS XL 3000VA Rack-Mountable UPS. Renowned for network-grade power protection, this UPS covers servers, storage, and networking gear with reliable clean power and scalable runtime. With the ability to configure up to 10 matching battery packs, you can extend uptime well beyond 24 hours, ensuring business continuity during long outages or maintenance windows. Designed for data centers, server rooms, and professional IT environments, the Smart-UPS XL combines rugged reliability with flexible deployment in both rack and tower configurations.

  • Reliable, scalable power protection: Delivers clean, consistent power to sensitive devices, safeguarding against outages, surges, and voltage sags that can compromise data integrity and uptime.
  • Extended runtime with battery-pack scalability: Configure up to 10 matching battery packs to achieve runtimes exceeding 24 hours at moderate loads, giving you the freedom to plan downtime with confidence.
  • Rack-mountable versatility: Specifically engineered for data centers and IT closets, the XL series fits neatly in 2U rack spaces and offers flexible deployment in tower or rack-mount form factors to match your existing infrastructure.
  • Network-grade protection for IT assets: Provides stable, regulated power with protection for connected servers, storage devices, switches, and other critical equipment, helping minimize data loss and hardware wear.
  • Trusted reliability and scalable management: Part of the widely deployed APC Smart-UPS family, known for robust performance, remote management options, and seamless integration with standard IT/network monitoring workflows.

Technical Details of APC Smart-UPS XL 3000VA Rack-Mountable UPS

  • VA rating: 3000 VA
  • Output power: 2400 W (80% of capacity, typical for a 0.8 power factor)
  • Form factor: Rack-mountable 2U design with optional tower configuration for versatile deployment
  • Runtime scalability: Supports up to 10 matching battery packs to extend runtime beyond 24 hours depending on load
  • Protection features: Network-grade power protection with automatic voltage regulation (AVR) to correct minor voltage fluctuations without switching to battery
  • Energy efficiency: Designed to minimize energy waste while delivering reliable power to critical devices
  • Monitoring and management: Compatible with standard IT management tools and monitoring software for remote status checks and graceful shutdowns

How to install APC Smart-UPS XL 3000VA Rack-Mountable UPS

Installing an APC Smart-UPS XL 3000VA in a rack or tower environment is straightforward when you follow a few best practices. The steps below outline a typical installation workflow to help you get up and running quickly while preserving performance and safety. Always refer to the user manual for model-specific guidance and safety precautions.

  1. Plan the installation site: Choose a location with adequate ventilation, stable temperature, and easy access to a 120–240 V power source. Ensure the rack or cabinet has sufficient clearance for airflow, cable routing, and the weight of the UPS and any attached battery packs.
  2. Mount the UPS in the rack: Use the provided rack-mount rails and hardware to secure the UPS in a stable 2U space. If you’re deploying in a tower configuration, place the unit on a flat, non-slip surface and ensure it remains stable during operation.
  3. Install battery packs (if applicable): Attach any matching battery packs to the UPS per the installation guide. Battery packs expand runtime and should be added in matched sets to maintain optimal performance and balance.
  4. Connect loads and power: Connect your critical devices (servers, storage, switches) to the UPS’s outlets or to the UPS’s load segments as recommended. Route cables neatly to avoid obstructing airflow. Then connect the UPS to the main power source using the appropriate input power cord.
  5. Power up and configure: Switch on the UPS and let it perform its self-test. Use the LCD panel or connected management software to configure runtime settings, alarms, and shutdown behavior. Scan for devices in your monitoring system and set up alerts for power events.
  6. Test the shutdown and recovery process: Simulate a brief power interruption to verify that connected equipment gracefully shuts down (or continues protected operation) and that the system restarts cleanly when power is restored.

Frequently asked questions

Q: What makes the APC Smart-UPS XL 3000VA suitable for data centers?
A: It combines a high 3000 VA/2400 W rating with scalable runtime, rack-mount flexibility, and network-grade power protection. It’s designed to safeguard servers, storage, and networking hardware, reducing the risk of data loss during outages and ensuring business continuity in demanding IT environments.

Q: How can I achieve runtimes beyond 24 hours?
A: The UPS supports up to 10 matching battery packs. By adding multiple, compatible battery packs, you can extend runtime significantly beyond 24 hours, depending on the actual load and pack configuration.

Q: Can I mount this unit in a standard 19-inch rack?
A: Yes. The APC Smart-UPS XL is designed for rack-mount deployment in 2U height, with the option to configure as a tower if needed to fit your space and equipment layout.

Q: What kind of power protection does it provide?
A: It offers network-grade protection with features such as voltage regulation, surge suppression, and clean, conditioned power to sensitive IT equipment, reducing the risk of brownouts and data corruption during power events.

Q: How do I manage and monitor the UPS?
A: You can monitor through on-device indicators (LCD/LED), plus compatible management software and network interfaces that provide status, alarms, and graceful shutdown commands for connected devices. This makes remote management straightforward for IT teams.

Q: Is installation difficult for someone with standard IT experience?
A: For most IT environments, installation is straightforward. Basic rack-mounting, battery pack installation, load connections, and initial configuration can be completed by personnel with routine hardware setup experience. When in doubt, consult the technical manual or a professional installer.