APC Static Bypass Transfer Switch


Price:
Sale price$2,908.26

Description

APC Static Bypass Transfer Switch - 40kVA

The APC Static Bypass Transfer Switch with a 40kVA rating is a cornerstone solution for mission‑critical environments that demand uninterrupted power and streamlined maintenance. Designed to work in concert with APC uninterruptible power supplies (UPS), this static bypass switch creates a dedicated bypass path that lets technicians service the UPS without interrupting the load. With high reliability, fast transfer capabilities, and a rugged, scalable design, it delivers enterprise‑grade power protection for data centers, server rooms, telecommunications facilities, and any operation where uptime matters most.

  • Unmatched uptime with rapid, seamless transfer. The APC Static Bypass Transfer Switch provides an instantaneous bypass path that enables maintenance without a disruption to critical loads. In milliseconds, essential equipment remains powered while technicians inspect or service the UPS, reducing downtime risk and preserving service level agreements.
  • Optimized compatibility with APC UPS ecosystems. Engineered to integrate smoothly with APC UPS systems, the 40kVA bypass switch ensures a cohesive power path—minimizing configuration complexity and delivering a reliable, supported solution that aligns with APC’s engineering and safety standards.
  • Advanced monitoring, control, and remote management. Built for modern data centers, the switch includes robust monitoring capabilities and control options that help IT and facilities teams observe load, bypass status, and faults from on‑site or remote management interfaces, improving operational visibility and response times.
  • Rugged, scalable construction for demanding environments. Encased in a durable enclosure designed for front‑accessible installation, the unit supports growth through modular architecture and straightforward expansion paths, making it suitable for evolving data center footprints and backup architectures.
  • Flexible configurations and comprehensive protection. With multiple input/output configurations, 3‑phase power handling, and built‑in safety interlocks, the 40kVA transfer switch offers a versatile solution for complex power paths, ensuring safe operation during switching events and preventing accidental energization of critical circuits.

Technical Details of APC Static Bypass Transfer Switch - 40kVA

  • Power rating: 40 kVA / 32 kW (0.8 power factor typical) to support substantial critical loads with margin for future growth.
  • Configuration: 3‑phase, 4‑wire input and output paths designed to integrate with APC UPS ecosystems and common data center power architectures.
  • Transfer mechanism: Static bypass with automatic and manual bypass options to ensure continuous operation during maintenance windows or UPS servicing.
  • Enclosure and build: Rugged steel cabinet with front access, designed for reliability in data centers and equipment rooms; door interlocks and safety features standard or available as options.
  • Environmental and safety: Engineered for reliability in typical IT facility conditions, with safety interlocks and compliance considerations to support industry standards and best practices.
  • Remote management: Integrated or compatible with APC management tools for status monitoring, alarms, and remote control to support modern IT operational workflows.
  • Installation context: Suitable for rack‑mount or standalone installations within appropriate rack or cabinet environments, enabling efficient use of existing infrastructure and service corridors.
  • Certification and standards: Designed to meet applicable electrical safety and performance guidelines to support enterprise deployments and data protection requirements.

How to install APC Static Bypass Transfer Switch

Before you begin, ensure you have a qualified electrician and IT technician team aligned on the scope, protective earth connections, and adherence to local electrical codes. This installation guide provides a high‑level overview designed to complement manufacturer manuals and site procedures, focusing on safe, reliable integration with existing APC UPS and power distribution systems.

  • Plan and verify compatibility. Confirm the 40kVA bypass switch model aligns with your APC UPS family, the target input/output voltages, and the required enclosure configuration. Review system drawings, ensure clear access to the installation location, and verify room ventilation and clearance for service access.

  • Prepare the installation area. Install the cabinet in a clean, dry, temperature‑controlled space with adequate airflow. Ensure the mounting surface supports the weight and dimensions, and that there is room for cable routing, labeling, and future expansion if needed.

  • Mount and cable connections. Secure the switch in its intended location, then connect the input power feeds from the utility or transformer and the output feeds to the critical load circuits. Use properly rated cables and lugs, and follow local codes for conductor sizing and termination. Apply protective covers or interlocks as required for safety.

  • Integrate with the UPS and bypass path. Tie the transfer switch into the UPS output and the bypass circuit as specified by APC design guidelines. Configure any interlocks, alarms, and status indicators to reflect the intended maintenance and operational workflows.

  • Configure controls, alarms, and testing. Enable remote monitoring, set fault thresholds, and verify that the automatic and manual bypass pathways engage as designed. Perform functional tests to confirm rapid switching under simulated maintenance conditions, and document results for commissioning records.

After installation, run a complete validation cycle that includes normal operation checks, bypass path engagement, and alarm signaling. Train facility and IT staff on normal operating procedures and emergency contingencies, ensuring everyone understands how to trigger the bypass for maintenance without impacting critical loads.

Frequently asked questions

  • Q: What is a Static Bypass Transfer Switch?

    A: A Static Bypass Transfer Switch provides a dedicated, low‑impedance path around an incompatible or offline UPS, allowing maintenance or servicing without interrupting the load. It enables continued power delivery to critical equipment while the UPS is tested, repaired, or upgraded.

  • Q: How quickly does the switch transfer the load?

    A: The transfer is designed to occur in milliseconds, minimizing any transient interruption to critical loads and preserving service continuity during maintenance windows.

  • Q: Is the APC 40kVA Static Bypass compatible with all APC UPS models?

    A: Compatibility depends on the UPS family, configuration, and voltage requirements. Always confirm model‑level compatibility with APC product documentation and your specific SKU to ensure proper integration and support.

  • Q: What are the primary benefits of using a Static Bypass Switch?

    A: Key benefits include uninterrupted maintenance, reduced risk of downtime, simplified service windows, enhanced operational visibility, and a scalable path for future growth in data centers and critical facilities.

  • Q: How do I maintain and troubleshoot the bypass switch?

    A: Regular checks should cover alarm status, bypass path integrity, cable terminations, and enclosure condition. Use the APC management interface to monitor health, review fault logs, and perform diagnostic tests in line with the manufacturer’s recommendations.

  • Q: Can this switch support future upgrades or expansions?

    A: Yes. The design typically supports modular enhancements and configurations to accommodate evolving load requirements, additional circuits, or updated UPS and power distribution architectures, subject to model specifications and installation constraints.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews