APC Symmetra LX 8kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V


Price:
Sale price$29,496.25

Description

APC Symmetra LX 8kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

The APC Symmetra LX 8kVA is a high-performance, modular power protection solution designed for space-constrained data centers, server rooms, and network closets. Engineered for uptime, scalability, and ease of management, this tower UPS combines online, double-conversion technology with an N+1 redundant architecture and external runtime expansion. It delivers reliable power for essential IT workloads while minimizing footprint and complexity, making it ideal for businesses that demand continuous availability without compromising on space or budget. With 208/240V compatibility and a design that supports fast hot-swaps, the Symmetra LX helps you deploy robust power protection that grows with your infrastructure—without sacrificing performance or reliability.

  • Unmatched scalability and flexibility: Start with a compact 8kVA core and scale up to 16kVA in an N+1 configuration as your load grows. Modular power modules and external battery cabinets enable graceful expansion without system downtime, so you can protect more servers, storage, and network gear as your environment evolves.
  • Redundant, mission-critical protection: The N+1 architecture provides fault tolerance for vital equipment, ensuring continuous operation even if a single module requires maintenance or experiences a fault. This redundancy is essential for server rooms and data networks where downtime is costly or unacceptable.
  • Space-efficient tower design for tight spaces: Engineered for space-constrained environments, the Symmetra LX fits comfortably in tower form factors while delivering enterprise-grade protection. Its modular construction minimizes footprint in closets, telecom rooms, and edge locations where every square foot matters.
  • Robust 208/240V support and seamless integration: Designed to work with standard enterprise power distribution, the Symmetra LX integrates smoothly with existing electrical infrastructure. It supports consistent output at 208/240V, enabling straightforward deployment in data centers, edge facilities, and mixed-use spaces.
  • Intuitive management and proactive monitoring: Built-in management interfaces, status indicators, and remote access capabilities help you optimize runtime, battery health, load balancing, and firmware updates. With proactive alerts and comprehensive reporting, you can maintain peak performance with minimal effort.

Technical Details of APC Symmetra LX 8kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

  • Model: APC Symmetra LX 8kVA Scalable to 16kVA N+1 Ext. Run Tower
  • Topology: Online, double-conversion (24/7 power conditioning and clean output for sensitive IT gear)
  • Configuration: Tower form factor designed for space-constrained data centers and edge environments
  • Input/Output Voltage: 208/240V AC (configurable output to match facility distribution)
  • Redundancy: N+1 scalable architecture with hot-swappable power modules for maintenance without downtime
  • Runtime Expansion: External battery cabinets and modular runtime options to extend uptime as needed
  • Management: LCD/status display with local monitoring and compatibility with APC management software and Network Management Card
  • Efficiency and Power Quality: Active power factor correction and precise voltage regulation for maximum load protection
  • Protection Features: Overload protection, short-circuit protection, and automatic voltage regulation to stabilize irregular input conditions
  • Certification: Compliance with applicable safety and EMC standards to support enterprise deployments
  • Physical Characteristics: Compact tower chassis with hot-swappable modules for minimal service impact
  • Environmental Requirements: Rated for typical data center ambient conditions with reliable performance in conditioned rooms

how to install APC Symmetra LX 8kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

  • Plan the deployment: Assess your load requirements and determine the appropriate starting 8kVA configuration with an eye toward future expansion to 16kVA N+1. Map input and output connections to existing power distribution.
  • Mount and position: Place the tower UPS on a solid, level surface with adequate clearance for cooling, cable management, and future cabinet additions. Ensure ventilation paths are unobstructed.
  • Connect input power: Attach the 208/240V input cables to the appropriate circuit from your distribution panel. Use proper protective devices and ensure the supply is within the recommended operating range.
  • Configure output and loads: Connect your critical servers, storage devices, and network equipment to the UPS output. Verify that feeders and racks are balanced and that the load does not exceed the 8kVA baseline, planning for future expansion.
  • Enable management features: Power up the system and access the LCD interface or Network Management Card to configure alerts, battery test schedules, and firmware updates. Set up remote monitoring and email or SNMP alerts for proactive maintenance.
  • Plan maintenance and expansion: Schedule periodic battery tests and module checks. When expanding to 16kVA, install additional power modules and external runtime cabinets as per the expansion plan, verifying redundancy is preserved during the upgrade.

Frequently asked questions

  • Q: What makes the APC Symmetra LX suitable for space-constrained environments?

    A: Its tower form factor, modular architecture, and hot-swappable components are designed to maximize protection while minimizing footprint. This combination delivers enterprise-grade power in a compact footprint ideal for tight data centers and edge facilities.

  • Q: Can I start with 8kVA and scale to 16kVA without downtime?

    A: Yes. The scalable architecture allows adding power modules and external runtimes while the system remains operational, enabling seamless growth as your workload increases.

  • Q: What kind of loads is this UPS best suited for?

    A: Critical IT workloads including servers, storage, virtualization hosts, and network infrastructure that require clean, stable power and high availability in a compact space.

  • Q: How do I monitor performance and battery health?

    A: Use the built-in LCD interface or APC Network Management Card to monitor runtime estimates, load, energy usage, battery health, and alerts. Regularly scheduling battery tests helps maintain readiness.

  • Q: Is external runtime a must for longer outages?

    A: External battery cabinets provide extended runtime beyond the internal battery capacity, allowing you to extend uptime during longer outages or to gracefully shutdown systems with ample reserve.