Description
APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V
The APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount is a high-performance, redundant power protection solution designed for space-constrained server rooms, top-of-rack networks, and critical voice and data infrastructures. This modular, scalable UPS system provides both immediate protection against power disturbances and long-term uptime with flexible runtime options. Built to fit tight IT spaces, it combines power density with intelligent management, ensuring your equipment stays online during outages and transitions with minimal impact on operations. Whether you’re outfitting a new data center or upgrading an existing footprint, the Symmetra LX delivers scalable capacity, robust redundancy, and simplified maintenance for uninterrupted service.
Engineered for reliability, the Symmetra LX supports scalable power from 8kVA up to 16kVA in an N+1 configuration, delivering continuous protection as your load grows. Its modular architecture allows you to add power modules and battery modules without shutting down critical systems, making it ideal for environments where uptime is non-negotiable. With 208/240V input compatibility, this rack-mount UPS aligns with standard data-center power distribution schemes, reducing installation complexity and enabling seamless integration with existing infrastructure. This adaptability is particularly valuable for mixed workloads that include servers, storage arrays, network gear, and voice/data networks requiring dependable power and predictable performance.
Beyond raw power, the Symmetra LX emphasizes intelligent management and energy efficiency. The system’s scalable runtime options let you tailor battery capacity and backup time to meet service level agreements, while redundant components minimize single points of failure. In practice, this means you can perform maintenance or component swaps with minimal downtime, and your critical services remain protected during growth or expansion. The result is a safer, more resilient data center footprint that can respond fluidly to changing IT demands—without compromising reliability or performance.
Key features and benefits
- Scalable power architecture: Start with an 8kVA baseline and expand to 16kVA with N+1 redundancy to accommodate increasing IT loads while maintaining continuous protection for servers, storage, and network gear.
- Modular, hot-swappable design: Replace or upgrade power modules, battery modules, and hot-swappable fans without interrupting critical operations, reducing maintenance windows and total cost of ownership.
- Space-efficient rack-mount footprint: Optimized for tight data-center spaces and edge environments, delivering high power density in a compact enclosure that fits standard 19-inch racks.
- Flexible runtime options: Expandable battery capacity and runtime management let you customize outage protection to meet specific SLAs, ensuring meaningful data retention during outages.
- Advanced management and monitoring: Integrated monitoring, remote visibility, and compatibility with DCIM and standard management protocols help IT teams anticipate failures, plan maintenance, and optimize energy use.
Technical Details of APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V
- Get this information from the specifications section of the product in the official catalog (Synnex EC) using UPC or SKU as reference.
How to install APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V
- Prepare the rack space: Verify that the rack is compliant with 19-inch equipment, has adequate weight capacity, and provides adequate clearance for heat dissipation and ventilation.
- Configure redundancy: Plan N+1 redundancy by installing the required number of primary power modules and one additional module to cover a single-point failure scenario.
- Mount the UPS in the rack: Secure the primary UPS unit and any modular power or battery modules in approved positions, following the manufacturer’s alignment and grounding guidelines.
- Connect input power: Route 208/240V input power to the UPS according to local electrical codes, ensuring proper grounding and phase balance for stable operation.
- Connect output and load: Link the UPS output to the IT equipment and ensure proper isolation from bypass paths. Verify all connections to servers, storage, and network devices.
- Install and configure batteries: Install battery modules (as required for runtime goals) and verify their health with the UPS management interface. Calibrate any required battery tests per the manual.
- Initialize the system: Power up the unit, perform self-tests, and configure monitoring settings (SNMP, USB, or serial interface) to align with your DCIM tools and alerting policies.
- Test everything: Simulate a power disturbance to confirm automatic transfer to battery, maintain load protection, and verify that redundant paths behave as expected during maintenance scenarios.
Frequently asked questions
-
Q: What does N+1 redundancy mean for the APC Symmetra LX?
A: N+1 redundancy means there is one additional, spare component or module beyond the required capacity to support the load. In the Symmetra LX, this translates to extra power modules and battery modules that keep critical servers online even if a primary module fails or is undergoing maintenance, ensuring uninterrupted service.
-
Q: Can the Symmetra LX scale from 8kVA to 16kVA without downtime?
A: Yes. The modular architecture supports online addition of power and battery modules, enabling capacity expansion and runtime extension without pulling critical systems offline. This makes it suitable for growing data centers and edge deployments where uptime is essential.
-
Q: What power configurations are supported?
A: The unit is designed for 208/240V input and output configurations, which align with common data-center and enterprise power systems. This compatibility helps streamline installation and reduces the need for complex power conversion equipment.
-
Q: How does the Symmetra LX help with energy efficiency?
A: The Symmetra LX employs efficient power conversion, modular design that minimizes unused capacity, and load-aware management, which contribute to lower energy waste and better overall facility energy performance. The ability to scale runtime also avoids unnecessary battery drain when loads are lower than predicted.
-
Q: What management options are available?
A: The system offers integrated management interfaces and supports remote monitoring via standard protocols. IT teams can leverage these tools for proactive maintenance, real-time health checks, and alerts to DCIM platforms, ensuring fast response times to any power event.
-
Q: Are battery modules replaceable without affecting uptime?
A: Yes. The assembly is designed for hot-swappable battery modules, allowing you to replace or upgrade battery capacity without powering down connected equipment, maintaining continuous protection during maintenance windows.