Description
APC Symmetra LX Extended Run Rack-mount with 3 SYBT5
The APC Symmetra LX Extended Run Rack-mount with 3 SYBT5 is an enterprise-grade, modular uninterruptible power supply (UPS) solution designed to protect critical IT infrastructure with extended runtime. Built for data centers, server rooms, network closets, and telecom environments, this rack-mounted system delivers scalable power protection, intelligent management, and dependable performance when it matters most. With an emphasis on reliability, uptime, and ease of maintenance, the Symmetra LX Extended Run configuration blends a flexible modular architecture with spill-proof, maintenance-free lead-acid batteries to keep servers, storage, and networking gear running through outages and disturbances. Whether you are expanding capacity, upgrading protection, or consolidating equipment in a high-density rack, this solution provides a robust foundation for uninterrupted operations.
- Extended runtime for critical workloads: Equipped with 3 SYBT5 battery modules, this configuration is optimized to provide longer backup times for essential servers, switches, and telecommunications equipment, helping you ride out outages without sacrificing performance or productivity.
- Modular and scalable protection: The Symmetra LX design supports scalable capacity and redundancy. Add power modules or additional battery blocks as your data center grows, without replacing the entire system, to align protection with evolving business needs.
- Reliable spill-proof, maintenance-free batteries: Lead-acid chemistry with a spill-proof, maintenance-free design delivers dependable charging performance and predictable life cycles, reducing maintenance overhead and lowering total cost of ownership.
- Redundant power paths and enhanced protection: Built to shield critical devices from power disturbances, this solution offers redundant paths, surge protection, and precise voltage regulation to safeguard servers, storage, and networking gear against outages and surges.
- Smart monitoring and enterprise management: Integrated management interfaces, remote monitoring, and compatibility with APC software ecosystems allow proactive alerts, remote configuration, and visibility across the data center, ensuring you stay ahead of potential issues.
Technical Details of APC Symmetra LX Extended Run Rack-mount with 3 SYBT5
- Battery chemistry: Lead-Acid, spill-proof, maintenance-free design for safer charging and reliable long-term operation.
- Battery modules included: 3 SYBT5 modules designed to extend runtime and support rapid replacement without interrupting connected loads.
- Form factor: Rack-mount configuration compatible with standard 19-inch racks, suitable for data centers and enterprise environments.
- Topology and architecture: Modular, scalable UPS with redundant power paths to maximize availability and minimize single-point failures.
- Protection features: Comprehensive protection for servers, networks, and telecom equipment, including surge suppression, voltage regulation, and short-circuit protection.
- Runtime characteristics: Extended runtime is configurable based on load; runtime varies with load and battery health, with designs optimized for critical workloads.
- Management and monitoring: Local console options and remote management through APC software, SNMP, and secure web interfaces for real-time monitoring and alerting.
- Operating environment: Engineered for data-center environments with recommended temperature and humidity ranges to ensure optimal battery performance and longevity.
- Certifications and standards: Typical compliance includes UL-listed, CE-marked, and RoHS-compliant designs to meet global regulatory requirements.
How to Install APC Symmetra LX Extended Run Rack-mount with 3 SYBT5
- Step 1: Plan rack space and airflow. Verify the rack has proper grounding and sufficient clearance for heat dissipation, cable management, and maintenance access.
- Step 2: Install the main Symmetra LX rack-mount unit into the rack rail kit. Align, secure, and verify that the chassis is level and firmly fastened.
- Step 3: Insert and connect the 3 SYBT5 battery modules in their designated slots, ensuring proper engagement and secure electrical connections for hot-swappable operation.
- Step 4: Connect input power to the UPS according to your electrical configuration (single-phase or three-phase as applicable), using appropriate breakers, power cables, and grounding practices.
- Step 5: Connect protected devices (servers, storage, networking gear) to the UPS output receptacles or distribution panel, configuring load distribution as needed for redundancy.
- Step 6: Power on the system and access the management interface. Configure IP settings, user accounts, alert preferences, and any integration with APC management software or data-center infrastructure management tools.
- Step 7: Run a self-test and verify battery status, runtime estimates, and alarm thresholds. Confirm that monitoring dashboards reflect correct load, voltage, and health indicators.
Frequently asked questions
-
Q: What is the benefit of the Extended Run configuration with 3 SYBT5 batteries?
A: The 3 SYBT5 battery modules provide extended runtime for critical systems, enabling longer backup periods during power outages and allowing time for graceful shutdowns or failover to alternative power sources without interrupting essential services. -
Q: Can I upgrade or replace battery modules without powering down the system?
A: Yes. The SYBT5 batteries are designed for hot-swappable operation in compatible Symmetra LX configurations, allowing maintenance and replacement with minimal or no interruption to protected loads. -
Q: What kinds of devices can be protected by this unit?
A: It is intended for servers, storage, switches, routers, and telecom equipment commonly found in data centers and enterprise networks, delivering clean, stable power to critical infrastructure. -
Q: How do I monitor and manage the APC Symmetra LX?
A: You can monitor via built-in management interfaces, the APC management software suite, SNMP, or secure web access. Alerts, event logs, and runtime estimates help you plan maintenance and capacity expansions. -
Q: Are there any special installation requirements?
A: Ensure proper rack space, adequate ventilation, correct grounding, and appropriate electrical service for your configuration. Follow safety guidelines and local electrical codes during installation.