APC Symmetra LX Intelligence Module


Price:
Sale price$3,010.28

Description

APC Symmetra LX Intelligence Module: Advanced Management for Scalable Power Protection

The APC Symmetra LX Intelligence Module elevates the capability of your Symmetra LX modular power system by introducing intelligent monitoring, centralized management, and seamless integration with APC’s broader data center ecosystem. Designed for data centers, remote offices, and hybrid environments, this module delivers granular visibility into power, environment, and runtime health, enabling proactive maintenance, optimized capacity planning, and rapid incident response. By unifying management across racks, rows, and sites, the Intelligence Module helps you maximize uptime, reduce operational complexity, and extend the life of your Symmetra LX investment.

  • Maximize uptime with proactive health monitoring: The Intelligence Module continuously gathers critical health metrics from Symmetra LX components, including battery status, inverter health, capacitor condition, input/output voltage and frequency, load balance, and temperature. With predictive analytics and configurable thresholds, you receive early warnings before degradation becomes service-impacting, enabling preventive maintenance that minimizes unplanned outages and improves service levels for critical workloads. This capability is essential in dense data centers and edge deployments where downtime carries substantial cost and risk.
  • Centralized management and reporting for actionable insight: This module consolidates telemetry into an accessible interface, delivering real-time dashboards, historical trends, event correlation, and comprehensive reports. Operators gain at-a-glance visibility into system health, energy usage, power factor, and runtime projections across multiple units and locations. The result is streamlined change management, faster root-cause analysis, capacity planning that aligns with workloads, and better adherence to service-level agreements (SLAs) through verifiable data and auditable records.
  • Seamless integration with the APC ecosystem and DCIM tools: Built to fit within the APC NetShelter and StruxureWare/ EcoStruxure for data centers, the Intelligence Module communicates with APC management software and compatible DCIM platforms. This integration enables centralized firmware management, synchronized alerts, automated reporting, and coordinated responses to power events. It also supports firmware updates across modules and chassis components, ensuring your infrastructure remains current with minimal disruption and without requiring a forklift upgrade to the entire system.
  • Flexible deployment that scales with your data center strategy: The modular design supports growing loads and evolving rack configurations without replacing existing hardware. As your IT footprint expands, you can add or upgrade Intelligence Modules to maintain consistent visibility and control. The solution is adaptable to traditional enterprise data centers, colocation facilities, and growing edge sites, helping you standardize Power, Cooling, and IT management practices across disparate environments while protecting your initial investment.
  • Secure remote access, reliability, and governance: Security is embedded at the core, with role-based access control, encrypted communications, and audit logging to protect sensitive power management data. The Intelligence Module supports secure remote management across multiple sites, enabling operators and facilities personnel to respond quickly to incidents while maintaining compliance with internal policies and regulatory requirements. This focus on security and reliability reduces risks associated with remote operations and helps preserve business continuity.

Technical Details of APC Symmetra LX Intelligence Module

  • Form factor and compatibility: The Intelligence Module is designed as a modular add-on for the Symmetra LX family, aligning with its scalable architecture and maintaining compatibility with existing Symmetra LX power, distribution, and monitoring components. It preserves the integrity of your current installation while unlocking enhanced control and visibility across modules and sites.
  • Management interfaces: Provides multiple integration paths, including SNMP (v2/v3), IPMI, and a secure web-based management interface. This multi-protocol approach enables compatibility with standard data center monitoring systems, DCIM platforms, and third-party analytics tools, ensuring you can incorporate the Intelligence Module into your existing management workflows with minimal disruption.
  • Remote monitoring and telemetry: Delivers comprehensive data points such as input/output voltages, current, frequency, total and partial load, battery health indicators, expected runtime, environmental readings where applicable, and alarm status. Real-time telemetry supports proactive maintenance and data-driven decision-making for capacity planning and risk mitigation.
  • Security and access governance: Implements role-based access control, audit trails, secure authentication, and encrypted data transmission to protect sensitive power management information. These security features help organizations meet internal security standards and external regulatory requirements while maintaining operational reliability.
  • Firmware lifecycle and compatibility: Features firmware upgrade capability that can be performed remotely or during maintenance windows, with compatibility checks to minimize downtime. Regular updates keep the Intelligence Module aligned with the latest features, security improvements, and performance enhancements available for the Symmetra LX ecosystem.

how to install APC Symmetra LX Intelligence Module

  • Prepare the site and review safety procedures: Before handling any live equipment, ensure power is managed according to your data center’s safety protocols. Verify that you have access to the supported management network and that you have the appropriate permissions to modify the Symmetra LX configuration.
  • Power down and isolate the chassis per standard procedures: If required by your maintenance window, power down the affected Symmetra LX enclosure following manufacturer guidelines. In many configurations, the module can be installed with minimal disruption, but always follow your facility’s change-management process.
  • Locate the designated intelligence module slot: Identify the correct slot or slot family within the Symmetra LX enclosure intended for the Intelligence Module. Align connectors with the backplane and ensure the module is oriented correctly to seat securely.
  • Install the module and secure it: Insert the Intelligence Module firmly until it seats with a defined tactile engagement. Secure mounting hardware as specified by the chassis design to prevent movement or dislodgement during normal operation or maintenance.
  • Connect management interfaces and power (if required): Attach the appropriate network connections (Ethernet) and any required management interfaces. Ensure cabling adheres to your facility’s cabling standards and routing policies to preserve airflow and minimize interference.
  • Power up, configure, and validate: Restore power if you had a maintenance window, access the management interface, and perform initial configuration. Register the module with the central UPS management suite, assign appropriate credentials, and verify that telemetry flows correctly from the Symmetra LX panels to the Intelligence Module. Run a validation to confirm dashboards, alarms, and reports populate as expected.

Frequently asked questions

  • Q: What is the APC Symmetra LX Intelligence Module?

    A: It is an optional, dedicated module that enhances the Symmetra LX modular power system with advanced monitoring, secure remote management, and tighter integration with APC’s management software and data center infrastructure ecosystem. It serves as a bridge between power equipment and DCIM tools, enabling proactive maintenance and data-driven decision making.

  • Q: Which systems does it integrate with?

    A: It is designed to integrate with the Symmetra LX platform and APC management tools, including NetShelter, StruxureWare, and EcoStruxure-ready environments. It can also interface with standard DCIM solutions via SNMP/IPMI, allowing centralized monitoring across multiple sites and equipment families.

  • Q: What kind of data can I expect from the Intelligence Module?

    A: Real-time and historical telemetry on power parameters (voltage, current, frequency, load), battery health and remaining capacity, environmental readings, event logs, and trend analyses for capacity planning and preventive maintenance. These insights help you predict failures before they impact operations.

  • Q: Do I need downtime to install or upgrade the module?

    A: Installation is designed to be non-disruptive in many configurations, with hot-swappable options in supported setups. However, it is recommended to perform installations or upgrades within a maintenance window following your change-management policy to ensure stable network and data center operations.

  • Q: How do updates affect security and compliance?

    A: Firmware updates are designed to strengthen security, improve reliability, and add features. Updates should be applied per APC guidelines, and organizations should maintain proper change control and audit logs to demonstrate compliance with internal and external standards.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed