Description
APC Symmetra RM 6kVA N+1 Frame 208/240V
Experience enterprise-grade power protection with the APC Symmetra RM 6kVA N+1 Frame 208/240V. Built for mission-critical environments, this highly available single-phase UPS delivers scalable, redundant, double-conversion online protection for voltage-sensitive equipment. It provides seamless, zero-transfer-time switching to battery power, ensuring that servers, storage arrays, networking gear, and other critical IT assets stay online during outages or brownouts. The Symmetra RM frame is designed for data centers, server rooms, and network closets where uptime is non-negotiable and space is at a premium.
- Zero transfer time to battery thanks to true online double-conversion topology, keeping sensitive equipment safe from voltage sags, surges, and outages.
- N+1 redundancy with modular, scalable architecture that grows with your data center needs, ensuring high availability without compromising footprint.
- Rugged RM frame design that supports seamless expansion through hot-swappable power modules and battery packs, reducing maintenance windows and downtime.
- Intelligent management and monitoring capabilities enable proactive maintenance, remote supervision, and easy integration with existing IT and facility systems.
- Designed for energy efficiency and low total cost of ownership, delivering reliable power protection for critical workloads while optimizing operational expenses.
Technical Details of APC Symmetra RM 6kVA N+1 Frame 208/240V
- Topologie: Online, double-conversion UPS for continuous power quality and instantaneous response to disturbances.
- Power rating: 6 kVA (approximately 4.8 kW at 0.8 power factor), suitable for protecting racks of servers and networking equipment.
- Input/output voltage: 208/240 VAC, single-phase configuration optimized for modern data center feeds.
- Redundancy: N+1 architecture that provides an extra module for fault tolerance, maintaining uptime during maintenance or component failures.
- Form factor: RM (rack-mountable) frame designed for compact data centers and cabinet-based deployments with scalable expansion.
- Scalability: Modular design allowing hot-swappable power and battery modules to grow capacity without service interruption.
- Protection features: All-around power conditioning, voltage regulation, and protection against transient spikes for continuously protected loads.
- Management: Integrated management options and compatibility with standard monitoring protocols for easy integration into data center infrastructure management (DCIM) ecosystems.
How to install APC Symmetra RM 6kVA N+1 Frame 208/240V
Installing the Symmetra RM 6kVA N+1 Frame starts with careful planning of your space, power distribution, and cabling. Begin by confirming your data center or server room layout supports a rack-mountable UPS with adequate airflow and clearance for service access. Ensure you have a dedicated, grounded 208/240V single-phase supply that can carry the load and leave room for growth. Position the RM frame in a well-ventilated, accessible location close to the loads it will support, with a clear path for maintenance and battery replacement. For best results, place the system in or near the IT rack(s) that will receive protected power, minimizing cable runs and electrical impedance.
Step-by-step installation steps:
- Unpack and inspect: Verify the packaging contents, inspect for any transit damage, and confirm all modular components are present, including power modules and battery modules if applicable.
- Mount the frame: Secure the RM frame to the rack with the appropriate mounting hardware, ensuring level alignment and solid anchoring for stable operation.
- Connect input power: Route the 208/240V input feeder from the main distribution panel or dedicated UPS feeder to the input connections on the RM frame. Use properly rated cables and ensure correct phase alignment and grounding.
- Connect protected loads: Tie the critical IT equipment, servers, storage, and network devices to the UPS output outlets or distribution panels fed by the Symmetra RM, following your data center’s wiring diagrams and PUE requirements.
- Configure management and redundancy: Connect the UPS to your network or management console, configure the N+1 redundancy settings if required, and enable remote monitoring features. Validate battery health, charge state, and alarm thresholds.
- Power-up and test: Initiate a controlled power-on sequence, observe the startup indicators, and perform a brief load test to verify proper operation. Confirm that the output voltage remains within spec and that transfer times are within acceptable limits.
- Documentation and change control: Record the installation details, load distribution, maintenance windows, and any firmware or software updates. Establish a routine for battery health checks and periodic testing according to your IT policy.
Ongoing maintenance is essential to keep the system performing at peak reliability. Schedule periodic battery health assessments, firmware updates, and configuration reviews. Leverage the modular design to perform maintenance in a staged manner, minimizing downtime and ensuring continuous protection for your critical assets. The Symmetra RM’s scalable architecture makes future expansions straightforward, allowing you to add capacity or redundancy without a complete system rework.
Frequently asked questions
-
Q: What does N+1 redundancy mean for the APC Symmetra RM 6kVA?
A: N+1 redundancy means there is at least one additional power module or pathway beyond the minimum required to support the load. If a module or path fails or requires maintenance, the extra module ensures uninterrupted power to your critical equipment, delivering higher availability and minimizing downtime. -
Q: What is the benefit of online double-conversion topology?
A: Online double-conversion converts incoming AC power to DC and back to AC continuously, providing clean, regulated output regardless of input fluctuations. This topology eliminates transfer time, protects sensitive devices from brownouts, and maintains consistent voltage and frequency under varied conditions. -
Q: Can I expand the Symmetra RM frame as my data center grows?
A: Yes. The RM frame is designed for modular scalability, allowing you to add additional power modules and battery packs to increase capacity and redundancy without interrupting existing loads. -
Q: How do I monitor and manage this UPS within a data center?
A: The Symmetra RM supports standard management interfaces and can be integrated into DCIM tools. You can monitor battery health, runtime estimates, input/output voltages, load levels, and alarm conditions from a central management console or through remote management software. -
Q: What kind of loads is this UPS best suited for?
A: It is ideal for voltage-sensitive equipment in data centers, server rooms, network closets, and other environments requiring high availability, such as critical servers, storage systems, virtualization hosts, and essential networking gear. -
Q: What maintenance should I perform regularly?
A: Regular maintenance includes checking battery health, verifying firmware and software updates, testing the transfer event (if applicable), inspecting cooling and ventilation, and reviewing alarm histories to preempt potential failures before they impact uptime.