B&B HEAVY INDUSTRIAL RS-232 REPEATER

B+B SmartWorxSKU: 3326801

Price:
Sale price$335.40

Description

The 232OPDRI-PH is our premium Heavy Industrial RS-232 Isolated Repeater. Engineered for rugged industrial environments, this device elevates serial communication by delivering galvanic isolation, reliable data integrity, and robust protection against electrical noise and ground loops. Designed to endure the demanding conditions found in control rooms, electrical substations, manufacturing floors, and harsh outdoor facilities, it passes some of the industry’s most exacting compliance tests. By isolating the RS-232 link, the 232OPDRI-PH safeguards both host equipment and remote devices, enabling longer cable runs, improved uptime, and seamless integration with existing serial networks. In short, it’s a trusted solution for critical automation and industrial control systems that demand dependable, uninterrupted serial performance.

  • Isolated RS-232 repeater for enhanced protection and extended reach: The 232OPDRI-PH provides galvanic isolation between the local host and the remote RS-232 device, helping to prevent ground loops, surges, and common-mode disturbances from corrupting data. This isolation makes it possible to place equipment in different electrical domains or far from noisy equipment, while maintaining reliable, error-free communication across the serial link.
  • Rugged, industrial-grade design for harsh environments: Built to thrive in demanding settings, the repeater features a durable enclosure and components selected for long life, resistance to vibration, and exposure to dust and humidity. The result is a Serial solution you can rely on in manufacturing plants, energy facilities, and outdoor installations, where environmental stress can otherwise degrade performance.
  • Compliance with key industry standards: The 232OPDRI-PH meets the requirements associated with IEC 61850-3 and IEEE 1613, signaling suitability for substation automation, power generation, and mission-critical control systems. This emphasis on standard-based reliability helps simplify integration into compliant architectures and supports interoperability with equipment across diverse vendors.
  • Easy integration with existing equipment and simple diagnostics: Designed for plug-and-play compatibility with standard RS-232 devices, the repeater minimizes installation complexity. Clear indicators and straightforward cabling make it easier to verify link health, troubleshoot issues, and maintain serial networks without specialized tools or extensive downtime.
  • Reliability you can count on for continuous operation: In environments where downtime is costly, the 232OPDRI-PH delivers dependable performance with robust electrical isolation, resilient signaling, and a commitment to durability. Its industrial focus means it’s built to withstand routine maintenance cycles, site variations, and the demanding cadence of automated processes.

Technical Details of B&B Heavy Industrial RS-232 Repeater

  • Model: 232OPDRI-PH
  • Interface: RS-232 isolated repeater
  • Isolation: galvanic isolation between serial ports to protect equipment and operators from ground loops and transients
  • Certifications: IEC 61850-3, IEEE 1613
  • Enclosure and construction: rugged industrial-grade housing designed for challenging environments

How to install B&B Heavy Industrial RS-232 Repeater

  • Step 1 — Select a suitable mounting location: Choose a position near the RS-232 devices you want to connect, ensuring adequate ventilation and protection from excessive dust, moisture, and handling hazards. Consider potential cable management paths to minimize bending and tension on the cables.
  • Step 2 — Prepare the RS-232 cabling: Use standard RS-232 cables suitable for your devices. Verify connector types and pinouts for input and output sides to ensure correct polarity and orientation before making connections.
  • Step 3 — Connect the input and output devices: Attach the host device to the repeater’s input port and connect the remote RS-232 device to the repeater’s output port. Tighten connectors to ensure a solid, low-resistance connection and prevent intermittent contact in vibration-prone environments.
  • Step 4 — Provide power and ground connections: Connect the repeater to its power supply according to the manufacturer’s instructions. Ensure ground references are in line with local electrical standards to maintain stable operation and to support the isolation features of the unit.
  • Step 5 — Power up and validate: Turn on the system and verify the device status indicators (as provided by the unit) to confirm the link is active. Conduct basic data transmission tests across the RS-232 link to confirm data integrity, timing, and error-free communication.
  • Step 6 — Document and monitor: Record installation details, including cable lengths, device IDs, and test results. Establish a routine check to observe link health over time, particularly in environments with persistent electrical noise or temperature fluctuations.

Frequently asked questions

  • Q: What is the purpose of the B&B 232OPDRI-PH?
    A: It acts as a galvanically isolated RS-232 repeater, extending serial communication distance while protecting connected equipment from ground loops, electrical noise, and transient disturbances.
  • Q: Is IEC 61850-3 and IEEE 1613 compliance important?
    A: Yes. Compliance indicates the device is suitable for electrical substations and other critical infrastructure environments, where stringent reliability and electromagnetic compatibility are essential.
  • Q: What environments is this product designed for?
    A: Rugged, heavy industrial environments such as control rooms, power plants, manufacturing floors, and outdoor facilities where serial communication must endure noise and interference.
  • Q: How does the installation process look?
    A: The unit is designed for straightforward integration with standard RS-232 devices. After mounting and cabling, you power it and verify link health using built-in indicators and basic signal tests.
  • Q: What should I consider when planning distance and cabling?
    A: While the exact maximum distance is not specified here, using high-quality RS-232 cables with proper shielding and keeping runs within recommended guidelines for your equipment will help maintain data integrity in industrial settings.