The B+B SmartWorx 485OPDR-HS is a high-speed, optically isolated RS-422/485 repeater engineered to extend and protect industrial communication in demanding environments. Designed for fieldbus networks and rugged facilities, this repeater preserves signal integrity over long distances, supports data rates up to 1.5 Mbps, and provides robust protection against electrical noise, surges, and electrostatic discharge. With optical isolation to separate noisy field devices from sensitive control systems, the 485OPDR-HS is an ideal choice for Profibus and other industrial networks where reliability and uptime are critical. Whether you’re integrating legacy equipment, expanding a distributed control system, or building a new automation backbone, this repeater helps maintain deterministic communication and reduces the risk of data errors across RS-422/485 segments.

  • High-speed RS-422/485 repeater: Extends the reach of your RS-422/485 networks with data rates up to 1.5 Mbps, enabling timely and dependable data exchange across devices, controllers, and field instruments used in automation, building management, and factory-floor control.
  • Optical isolation for safety and noise immunity: The 485OPDR-HS provides optical isolation that minimizes common-mode noise and isolates devices from potentially damaging transients, improving overall network reliability in electrically noisy environments.
  • Strong protection against mains disturbances: 2 kV digital isolation with 8 kV air ESD protection and 600 W transient voltage protection shield your critical control network from voltage spikes, EMI, and electrostatic events often encountered on the factory floor.
  • Profibus-ready fieldbus compatibility: Specifically suited for Profibus and similar fieldbus systems, the repeater helps you build scalable, multi-point networks while maintaining signal integrity and coordination across multiple devices and subsystems.
  • Easy integration and rugged reliability: Built for industrial use, the device supports straightforward deployment in harsh environments, with a compact form factor designed to fit into existing enclosures and control panels, while delivering dependable performance and long-term operation.

Technical Details of B+B SmartWorx High Speed Isolated RS-422/485 Repeater

  • Data rate support: Up to 1.5 Mbps, enabling rapid communication across RS-422/485 segments and suitable for time-sensitive fieldbus communications.
  • Isolation: Optical isolation between ports to improve noise immunity and protect critical devices from disturbances in remote nodes.
  • Digital isolation voltage: 2 kV digital isolation offering a robust barrier between connected networks and control electronics.
  • ESD protection: 8 kV air discharge protection to withstand electrostatic events typical in industrial environments.
  • Transient protection: 600 W transient voltage protection helping to absorb voltage spikes and protect connected devices during disturbances.
  • Network compatibility: Designed for RS-422/485 communication with fieldbus applications such as Profibus, enabling seamless integration into existing industrial architectures.
  • Applications: Ideal for extending multi-drop RS-422/485 networks, enhancing signal integrity in long cable runs, and isolating critical controllers from noisy field devices.

How to install B+B SmartWorx High Speed Isolated RS-422/485 Repeater

Installing the 485OPDR-HS is straightforward and designed to minimize downtime in industrial settings. Follow these guidelines to ensure reliable operation and preserve the integrity of your RS-422/485 network:

1) Plan your topology: Identify where the repeater will be placed in the network to optimize signal integrity. Position repeaters at points where long cable runs begin to degrade signal quality or where network segments with different electrical environments meet. Ensure there is a clean path for wiring away from high-noise equipment and sources of interference.

2) Prepare the cabling: Use shielded twisted-pair RS-422/485 cable for all data lines. Keep cables as short as possible and route them away from power lines, motors, and other EMI sources. If you have long runs, consider placing the repeater at a convenient midpoint to balance segment lengths and improve timing margins.

3) Connect the RS-422/485 lines: Attach the input (A/B) from the preceding device to the repeater’s input interface and connect the output (A/B) to the next device or segment. Observe proper polarity and labeling to prevent cross-wiring, which can cause communication errors or collisions on the bus.

4) Establish isolation and termination strategy: Take advantage of the optical isolation by keeping the isolator barriers intact, and configure line termination only at the ends of the RS-422/485 network as required by your overall topology and device recommendations. Ensure that unused ports remain properly terminated or isolated as per the installation guidelines to avoid reflections.

5) Power and grounding: Provide power to the repeater as specified in the installation guide and connect the ground references appropriately. Maintain a clean grounding scheme to minimize ground loops and reduce potential noise pickup on the bus.

6) Verify operation: After wiring, power up the system and perform a communication test across the RS-422/485 network. Confirm that devices on both sides of the repeater can send and receive data without errors. If performance issues arise, check cable integrity, termination resistors, and ensure that the data rate of 1.5 Mbps is compatible with all connected devices.

7) Enclosure and environmental considerations: Mount the repeater inside a controller cabinet or on a DIN rail if compatible with your enclosure. Provide adequate ventilation and conform to any relevant safety standards. Keep the device away from moisture, excessive heat, and direct exposure to harsh industrial conditions to prolong its service life.

8) Documentation and labeling: Record the installation details, including device serial numbers, network topology, and termination settings. Label cables and ports clearly to simplify maintenance and future upgrades.

By following these steps, you maximize the effectiveness of the B+B SmartWorx 485OPDR-HS and ensure stable, high-speed RS-422/485 communication across segments, while preserving the integrity of your fieldbus networks like Profibus. The repeater’s optical isolation and rugged protection features provide a robust foundation for scalable automation architectures where reliability is non-negotiable.

Frequently asked questions

  • What is the primary purpose of the 485OPDR-HS? It functions as a high-speed isolated RS-422/485 repeater, extending and protecting RS-422/485 communications in industrial environments. It is particularly well-suited for fieldbus networks such as Profibus, where signal integrity and isolation are important.
  • What data rate does it support? The device supports data rates up to 1.5 Mbps, making it suitable for real-time control and monitoring tasks across RS-422/485 segments.
  • What kind of isolation does it provide? It provides optical isolation to separate the data path from potentially noisy or fault-prone field devices, along with 2 kV digital isolation and 8 kV air ESD protection to guard against electrical disturbances.
  • What protections are included for harsh environments? It includes 8 kV ESD protection and 600 W transient voltage protection to shield connected equipment from spikes, surges, and electrostatic events common in industrial settings.
  • Is it compatible with Profibus and other fieldbus networks? Yes, it is designed for RS-422/485 networks and is suitable for fieldbus applications such as Profibus, helping you extend networks while maintaining compatibility and reliability.