Description
Black Box ClimateCab NEMA 12 Server Cabinet with 12000-BTU AC - 42U, M6 Rails, 230V
Engineered to protect critical equipment in demanding environments, the Black Box ClimateCab NEMA 12 Server Cabinet blends rugged, secure hardware enclosure design with built-in climate control. The side-mounted 12,000-BTU air conditioner keeps sensitive servers, switches, and storage at optimal temperatures, helping prevent overheating and ensuring reliability in data centers, server rooms, or network closets. With a fully welded 12-gauge steel frame, spacious 42U interior, and standard 19-inch rails, this cabinet is built to handle dense deployments while offering convenient access, secure locking, and effortless mobility. Whether you’re upgrading a small data room or equipping a telecom rack, ClimateCab provides a turnkey solution that balances cooling efficiency, storage capacity, and security in one robust enclosure.
- Powerful side-mounted cooling: The ClimateCab includes a 12,000-BTU air conditioning unit that mounts on the side of the cabinet, delivering targeted cooling exactly where equipment generates the most heat. This side-mount design simplifies installation, minimizes ducting, and keeps hot spots from forming in dense server rows. The AC unit operates with 230V power to maximize cooling efficiency for high-density deployments, helping sustain performance and extend equipment life even during peak workloads.
- Heavy-duty construction with generous capacity: Built on a fully welded 12-gauge steel frame, the ClimateCab is engineered to endure heavy use and physical stress in demanding environments. It supports up to 1500 pounds (680 kg) of equipment, so you can consolidate servers, storage, and network gear inside a single, organized enclosure. The 42U interior height provides ample space for multiple racks and future growth while maintaining a clean, professional appearance.
- Standardization and versatility for rack equipment: The cabinet features standard 19-inch rails with M6 mounting options, ensuring compatibility with a wide range of networked devices, servers, and cabinet accessories. Front and rear doors employ three-point locking handles for secure access from either side, giving IT staff confidence that critical hardware remains protected from tampering while still allowing rapid maintenance when necessary.
- Mobility, leveling, and installation convenience: The ClimateCab ships with casters and levelers, making it easy to reposition the cabinet during initial setup or future reconfigurations. The installation process for the side-mounted AC unit is designed for speed—typically about five minutes—so you can bring cooling online quickly without complex ducting or professional commissioning. The combination of casters, leveling, and a sturdy frame enables precise alignment and stable operation on uneven floors.
- Security, organization, and long-term reliability: In addition to three-point locking hardware, the ClimateCab provides solid enclosure security and a tidy interior for cable management and airflow optimization. The robust construction, secure access, and integrated cooling work together to minimize downtime and maximize uptime, making this cabinet a dependable foundation for growing IT environments where temperature control and physical security are critical.
Technical Details of Black Box ClimateCab NEMA 12 Server Cabinet
- Cabinet type: Climate-controlled server cabinet with side-mounted 12,000-BTU AC unit
- Material: Fully welded 12-gauge steel frame
- Interior capacity: 42U height
- Mounting rails: Standard 19-inch rails with M6 compatibility
- Weight capacity: Up to 1500 pounds (680 kg)
- Doors and locking: Front and rear doors with three-point locking handles
- Mobility: Includes casters and levelers for easy positioning and leveling
- Electrical requirements: 230V operation for the integrated AC unit
- Compliance: NEMA 12-rated enclosure for vapor and dust resistance in controlled environments
how to install Black Box ClimateCab
- Prepare the installation area: Ensure a clean, level floor with adequate ventilation and clearance for door access, service panels, and cable routing. Move the ClimateCab into position using appropriate lifting equipment if necessary, and verify that the floor load capacity supports the cabinet and its maximum weight.
- Unpack and orient the cabinet: Remove packaging carefully, inspect for any shipping damage, and orient the cabinet with the side-mounted AC unit accessible for connection. Confirm that the 19-inch rails and mounting hardware are present and intact.
- Install the side-mounted AC unit: Following the manual, attach the 12,000-BTU AC unit to the side of the ClimateCab. Ensure secure mounting and proper clearance for air intake and exhaust. Connect the unit to a suitable 230V power source as specified by the manufacturer, and route any required drainage or condensation lines as directed.
- Secure rails and install equipment: Attach the standard 19-inch rails with M6 compatibility inside the cabinet. Mount servers, switches, and storage devices in an organized layout, observing recommended load distribution and airflow considerations. Leave adequate space for cable management and cooling airflow to reach all devices.
- Final checks and commissioning: Close and lock both doors, verify caster levelers for stability, and confirm that the AC unit responds to control settings. Power on the system, monitor temperature readings, and adjust airflow as needed to maintain target environmental conditions. Perform a final sweep to ensure cables are neatly routed and do not obstruct vents or fans.
Frequently asked questions
-
Q: What does NEMA 12 imply for this ClimateCab?
A: NEMA 12 indicates a enclosure designed for indoor use that provides basic protection against dust, light splash, and non-hazardous oil or coolant splashes. It is well-suited for data centers, server rooms, and network closets where controlled environments help protect sensitive equipment.
-
Q: How much cooling capacity does the side-mounted AC provide?
A: The ClimateCab ships with a 12,000-BTU air conditioner, delivering robust cooling to keep densely populated racks within safe temperatures. This level of cooling is ideal for mixed workloads and high-density deployments within the cabinet footprint.
-
Q: Is installation of the AC unit truly quick?
A: Yes. The included AC unit is designed for a fast, five-minute installation on the cabinet’s side, enabling rapid deployment and minimal downtime when adding climate control to a server rack environment.
-
Q: What mounting standards are supported inside the cabinet?
A: The ClimateCab uses standard 19-inch rack rails with M6 compatibility, ensuring broad compatibility with a wide range of servers, switches, storage devices, and rack-mounted accessories.
-
Q: Can the cabinet be moved after setup?
A: The cabinet includes casters and levelers to facilitate mobility and precise leveling. While it is designed for stable operation, it can be repositioned as needed when floors are properly prepared and weight is distributed evenly.