Black Box DIN Rail Repeaters with Opto-Isolation, RS-422/RS-485

Black BoxSKU: 2889690

Price:
Sale price$247.34

Description

Black Box DIN Rail Repeaters with Opto-Isolation, RS-422/RS-485

Engineered for industrial environments where reliability and protection are non-negotiable, these Black Box DIN Rail Repeaters with Opto-Isolation deliver a complete solution for serial networks. They act as repeaters, isolators, and extenders, allowing you to protect sensitive equipment while expanding your system’s reach. The RS-422/RS-485 model isolates RS-422/485 devices, offering selectable data rates from 2400 bps up to 115.2 kbps to accommodate both slow sensors and fast controllers. By segmenting networks with opto-isolation, you can effectively overcome the traditional 32-node limitation and preserve data integrity even in electrically noisy environments. The RS-232 model isolates critical RS-232 channels (TD, RD, RTS, CTS), enabling clean, protected serial connections for legacy equipment. Combined, these DIN rail repeaters provide a compact, rugged, and scalable solution for industrial automation, process control, and building automation networks.

  • Isolates and protects: Opto-isolation creates a durable barrier between network segments, preventing voltage spikes, ground loops, EMI, and transient disturbances from propagating across devices. This protection translates into higher uptime, longer equipment life, and cleaner signals in challenging environments.
  • Flexible data rates: The RS-422/RS-485 variant supports selectable baud rates from 2400 bps to 115.2 kbps, enabling seamless integration with a wide range of serial devices—from low-speed sensors to high-speed controllers—without sacrificing compatibility or performance.
  • Extended node capacity: By isolating and segmenting RS-422/RS-485 networks, you can effectively extend the network beyond the conventional 32-node limit. This segmentation maintains signal quality while accommodating larger systems and more devices on a single control architecture.
  • RS-232 isolation option: The RS-232 edition isolates the TD, RD, RTS, and CTS lines, protecting connected PCs, printers, and other RS-232 peripherals from network disturbances and ground differences, while preserving full two-way communication.
  • DIN rail mounting for quick deployment: Designed for standard 35 mm DIN rails, these modules install quickly in control panels or equipment racks. The compact, rugged enclosure fits neatly into crowded electrical cabinets and stays secure under normal vibration and switching conditions.

Technical Details of Black Box DIN Rail Repeaters with Opto-Isolation, RS-422/RS-485

  • Interface options: Separate variants for RS-422/RS-485 differential signaling or RS-232 isolation, with clearly labeled input and output ports to simplify wiring and reduce installation errors.
  • Isolation: Opto-isolated barriers between segments guard devices from electrical noise, transients, and ground loops, preserving data integrity across longer runs and more devices.
  • Data rates: Wide support for baud rates ranging from 2400 bps up to 115.2 kbps, ensuring compatibility with legacy equipment and modern controllers alike.
  • Network topology support: Facilitates multi-drop RS-422/RS-485 configurations and cross-segment isolation to enable safer, scalable networks without sacrificing timing or reliability.
  • Mounting and form factor: DIN rail-compatible enclosure designed to minimize footprint in crowded control panels while delivering robust mechanical stability in industrial settings.
  • Power and environment: Built to work with common industrial power sources and DIN-rail environments, with rugged construction suitable for factory floors and harsh installations.

How to install Black Box DIN Rail Repeaters with Opto-Isolation

Installing these repeaters is a straightforward process that fits typical industrial panel workflows. Follow these steps to ensure a reliable, long-lasting setup:

  • Prepare power: Connect a suitable DC power supply to the device, within the manufacturer’s specified range. Verify proper grounding and ensure the power source complies with local electrical codes and safety standards.
  • Mount securely: Attach the repeater to a standard 35 mm DIN rail in a protected section of the control panel. Use the integrated mounting clip to secure it, making sure there is ample space for cable routing and cooling.
  • Wire the serial network: For RS-422/RS-485 models, land the differential pair(s) on the correct input and output terminals as labeled. For RS-232 models, connect TX, RX, and the control lines (TD/RD, RTS/CTS) to their respective ports, observing polarity and connector types.
  • Set the data rate: Configure the baud rate on the device to match all devices on the segment. Ensure the selected rate is identical across the transmitter and receiver nodes within each isolated section to prevent timing mismatches.
  • Verify isolation and continuity: Power up the system and use status LEDs or diagnostic indicators to confirm link activity and isolation status. Conduct a basic loopback or device-to-device test to confirm data integrity across segments.
  • Plan maintenance: Document the network topology, baud rates, and segment boundaries. Keep the installation manual accessible for future servicing, reconfiguration, or expansion.

Frequently asked questions

  • What problem do DIN rail repeaters with opto-isolation solve? They protect serial equipment from electrical noise, ground differences, and transient events while enabling longer distances and larger networks by segmenting RS-422/RS-485 or RS-232 links.
  • How does node expansion work? By splitting a large RS-422/RS-485 network into isolated segments, each segment can host multiple devices without compromising signal integrity, effectively overcoming the standard 32-node limitation.
  • Are there different models for RS-422/RS-485 and RS-232? Yes. The RS-422/RS-485 model focuses on differential signaling and network isolation for multi-drop environments, while the RS-232 model isolates individual transmit/receive and control lines (TD, RD, RTS, CTS) for legacy serial devices.
  • Can these be used with Modbus or other serial protocols? Absolutely. The devices support common serial communication standards and are suitable for Modbus RTU, ASCII, and other RS-232/RS-422/RS-485 based protocols, depending on the chosen interface variant.
  • What type of enclosure and installation environment is recommended? The units are designed for DIN rail mounting in industrial control panels and cabinets. They perform well in environments typical of automation and manufacturing, though it is advised to maintain adequate ventilation and comply with local electrical standards.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed