BTI UPS Battery Pack

BTISKU: 6697847

Price:
Sale price$89.28

Description

BTI UPS Battery Pack – 12V Sealed Lead-Acid UPS Backup Battery

The BTI UPS Battery Pack is engineered to deliver unwavering power when it matters most. As a trusted replacement or upgrade for a wide range of Uninterruptible Power Supplies, this 12V DC sealed lead-acid battery combines dependable performance with maintenance-free convenience. Whether you’re protecting critical servers, networking gear, security systems, or essential home electronics, this batteries pack is designed to keep your equipment online during outages, minimize data loss, and ensure smooth operations even during extended power disruptions. Built for reliability in demanding environments, the BTI Battery Pack offers robust cycle life, stable voltage delivery, and a compact footprint that makes it suitable for rack-mounted UPS systems and compact IT closets alike. With protection against leaks, low self-discharge, and safe, clean operation, it stands as a prudent long-term investment for any business or home setup that depends on uninterrupted power. The BTI Battery Pack is optimized to work quietly in the background, ensuring you can focus on your work or daily activities without worrying about sudden shutdowns. Its design emphasizes safety, environmental responsibility, and compatibility, providing a dependable power reserve that you can count on day after day.

  • 12V Sealed Lead-Acid UPS Battery Pack: Built on Valve-Regulated Lead-Acid (VRLA) chemistry, this battery pack delivers a spill-proof, maintenance-free solution with predictable performance. Its sealed construction minimizes venting in typical indoor environments, making it well-suited for server rooms, IT closets, and home offices where space is at a premium but reliability is non-negotiable. The 12V nominal output aligns with most UPS systems, enabling straightforward integration without compromising safety or efficiency.
  • UPS Compatibility and Plug-and-Play Installation: Specifically designed to replace or upgrade standard UPS batteries, the BTI Battery Pack offers a convenient, near plug-and-play experience. It is engineered to fit a broad range of 12V UPS models, with standardized connector arrangements and secure mounting options. Whether you need to extend runtime for an enterprise-grade UPS or refresh a consumer-grade unit, this pack is crafted to minimize downtime during replacement and maximize uptime thereafter.
  • Reliable Runtime and Deep-Cycle Performance: When the lights go out, your equipment stays powered thanks to consistent voltage delivery and dependable deep-cycle capabilities. The BTI Battery Pack maintains stable performance through multiple discharge-recharge cycles, helping to prevent voltage sag during outages and protecting sensitive electronics from abrupt shutdowns. You can expect reliable short-term runtimes for critical devices and solid longer runtimes for lighter loads, depending on the capacity of the specific SKU you choose.
  • Safe, Clean, and Eco-Friendly Design: The VRLA design focuses on safety and longevity, with built-in overpressure protection and low self-discharge to preserve charge when not in use. The battery is designed for easy handling and secure installation in typical UPS environments. Additionally, this battery pack is recyclable and produced with environmental considerations in mind, supporting responsible disposal and minimizing the lifecycle impact of your IT footprint.
  • Easy Replacement and Long-Term Savings: A cost-effective upgrade option, the BTI Battery Pack reduces maintenance needs and extends the life of your UPS by delivering consistent performance over time. Its compact form factor enables easy storage and installation in tight spaces, while providing a predictable, economical path to maintaining uptime without frequent battery replacements or service calls.

Technical Details of BTI UPS Battery Pack

The following technical details summarize typical specifications for this product. Exact values depend on SKU and model, so refer to the specific listing for your UPS configuration. Key features include:

  • Voltage and Chemistry: 12V nominal, sealed lead-acid (VRLA) chemistry for maintenance-free operation and dependable performance in a variety of environments.
  • Form Factor: Battery pack designed to fit standard UPS replacement modules, enabling straightforward swap-outs with minimal downtime.
  • Capacity: Available in multiple capacities depending on SKU. Capacity varies by model to support different runtimes; confirm the exact rating for your unit to estimate backup time accurately.
  • Operating Conditions: Optimized for typical indoor UPS environments, with recommended temperature ranges that maximize life and efficiency while reducing the likelihood of performance degradation under high-load conditions.
  • Safety and Compliance: VRLA design with built-in safety vents and robust terminal connections; recyclable after service life and compatible with common disposal guidelines for lead-acid batteries.

How to install BTI UPS Battery Pack

Proper installation ensures maximum safety and optimal performance. Follow these steps to replace or install the BTI UPS Battery Pack in compatible UPS units. Always power down and unplug the UPS before starting, and consult your unit’s manual for any model-specific instructions.

  • Power down the UPS and unplug it from the wall outlet. If your model supports battery replacement without unplugging, follow the manufacturer’s hot-swap guidelines and perform the replacement during a scheduled maintenance window.
  • Open the UPS battery compartment or cover. Carefully remove the old battery pack, taking note of the orientation and polarity of all connections to ensure correct reassembly.
  • Inspect the battery compartment for any corrosion, damaged cables, or debris. Clean the area if needed and replace any worn connectors before installing the new pack to prevent poor connections or arcing.
  • Position the BTI Battery Pack in the compartment, align mounting points as required, and connect the leads to the corresponding terminals. Ensure all connections are tight, secure, and free from strain or loose wires to minimize the risk of intermittent contact.
  • Secure the battery pack in place, replace the compartment cover, and reconnect the UPS to the AC outlet. Power on the unit and allow a brief initialization period. Run a self-test or, if your model supports it, perform a simulated power outage to confirm that the backup system engages correctly.
  • Document the replacement date and monitor the UPS’s performance over the next few cycles. Properly dispose of the old battery at an approved recycling facility in accordance with local regulations and guidelines.

Frequently asked questions

  • Q: Is the BTI UPS Battery Pack compatible with my UPS model? A: The pack is designed for 12V UPS systems that use VRLA replacement batteries. Confirm fit by checking your UPS model’s replacement battery specification, including voltage, capacity, and terminal configuration, and compare them to the BTI Battery Pack SKU you’re considering.
  • Q: How long will the BTI battery last on backup power? A: Runtime depends on the connected load and the capacity of the specific SKU. For heavier loads, expect shorter runtimes; for lighter loads, longer runtimes are achievable. Use the SKU’s rated capacity as a baseline to estimate backup time for your application.
  • Q: Are maintenance requirements for this battery? A: No routine maintenance is required for VRLA sealed lead-acid packs. Keep the battery within the recommended environmental conditions, ensure proper charging through the UPS, and periodically inspect connections to prevent corrosion or loose wires.
  • Q: Can I recycle the old battery? A: Yes. Lead-acid batteries are widely recyclable. Take the old battery to an approved recycling facility or return it to a retailer that accepts used batteries. Proper disposal helps protect the environment and supports responsible battery management.
  • Q: How should I store spare BTI Battery Packs? A: Store spares in a cool, dry, and well-ventilated area away from direct sunlight and heat sources. Avoid stacking heavy items on top of the batteries and check the charge periodically to minimize self-discharge.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed