Cisco Nexus N9K-C9332D-GX2B Ethernet Switch

CiscoSKU: 7431970

Price:
Sale price$47,531.91

Description

Cisco Nexus N9K-C9332D-GX2B Ethernet Switch

In the evolving landscape of data centers, where AI-powered applications, real-time analytics, and cloud-scale workloads push the boundaries of bandwidth and latency, you need a switch that combines performance, reliability, and intelligent automation. The Cisco Nexus N9K-C9332D-GX2B Ethernet Switch is purpose-built for modern data-center fabrics, delivering high-density, low-latency connectivity that scales with your business. Built on Cisco’s proven NX-OS platform and designed for leaf-spine deployments, this switch provides a future-proof foundation for multitenant, security-conscious infrastructures while simplifying day-to-day operations through automation-friendly features and advanced telemetry.

Whether you’re building a new data center from the ground up or expanding an existing one, the N9K-C9332D-GX2B is engineered to handle peak traffic from AI training, ML inference, big data analytics, and latency-sensitive applications. Its architecture prioritizes predictable performance and minimal jitter, ensuring that critical workloads receive consistent throughput even during traffic spikes. Cisco’s emphasis on operational intelligence means administrators gain deep visibility into network health, application performance, and capacity trends, enabling proactive management rather than reactive firefighting. This translates into faster deployment cycles, tighter security postures, and greater efficiency across the entire IT stack.

Beyond raw speed, the Nexus 9332D-GX2B emphasizes automation-ready management. NX-OS provides a mature, feature-rich CLI complemented by robust APIs, streaming telemetry, and simplified integration with common orchestration platforms. Operators can codify policy, automate routine tasks, and implement sophisticated traffic engineering with confidence. For multi-site and multi-tenant environments, the switch supports virtualization and segmentation features that reduce blast radii and improve overall security posture without sacrificing performance. In short, the N9K-C9332D-GX2B helps you move from isolated, manual configurations to a scalable, repeatable, and auditable network operating model.

As data centers grow more dynamic, so too does the need for visibility. The N9K-C9332D-GX2B integrates telemetry and analytics capabilities to provide actionable insights into traffic patterns, utilization, and fault domains. This empowers network engineers to pinpoint bottlenecks, verify SLAs, and optimize resource allocation in real time. The combination of high-density port options, flexible uplinks, and intelligent management makes this switch a compelling choice for organizations aiming to future-proof their infrastructure while delivering a consistently exceptional user experience for applications, developers, and tenants alike.

  • High-density, non-blocking forwarding fabric optimized for data-center scale and AI-driven workloads, delivering deterministic latency and consistent throughput even as traffic patterns shift with dynamic workloads. This ensures that latency-sensitive applications—such as real-time inference, streaming analytics, and high-performance compute (HPC) clusters—receive predictable performance under heavy load.
  • Flexible port and uplink architecture that combines high-speed 40/100 Gigabit Ethernet with versatile optics and cabling options, enabling easy integration into spine or leaf layers and future-proofing for evolving bandwidth requirements. The design supports seamless expansion as your data center grows from rack-scale to campus-scale deployments.
  • Advanced telemetry, analytics, and management through NX-OS with APIs, streaming telemetry, and Cisco Silicon capabilities that simplify monitoring, troubleshooting, and capacity planning across multi-site deployments. Operators can export telemetry data, integrate with analytics platforms, and automate health checks to reduce mean time to resolution.
  • Resilient hardware design with hot-swappable, redundant power options, hot-swappable fans, and robust fault isolation, ensuring high availability and minimal downtime in mission-critical environments. This architecture supports maintenance without disrupting services and helps meet strict uptime SLAs.
  • Security, virtualization, and policy-driven networking features including EVPN-VXLAN support, granular ACLs, and virtualization-friendly capabilities to enable micro-segmentation and multi-tenant isolation in large data centers. These capabilities simplify complex network policies while preserving performance and scalability.

Technical Details of Cisco Nexus N9K-C9332D-GX2B Ethernet Switch

Technical specifications are typically published by Cisco and the reseller partner network. As this listing provides a high-level overview, exact SKU and UPC values are not displayed here. For the most accurate and up-to-date specifications, consult the official Cisco data sheets and the Synnex/EC listing for the N9K-C9332D-GX2B.

  • SKU: Not provided in this listing
  • UPC: Not provided in this listing
  • Port density and type: High-speed 40/100 GbE ports with QSFP28 optics (design supports dense leaf-spine deployments)
  • Power options: Redundant hot-swappable power supplies (AC/DC options available)
  • Form factor: Fixed, rack-mountable data-center switch designed for 19-inch racks (1U/2U form factor variants depending on configuration)
  • Management and software: NX-OS with programmable APIs, REST/CLI access, streaming telemetry, and built-in analytics features
  • Security and virtualization: EVPN-VXLAN support, ACLs, micro-segmentation capabilities, and virtualization-friendly features to support multi-tenant environments

How to install Cisco Nexus N9K-C9332D-GX2B Ethernet Switch

Preparing for installation begins with a clean design and a well-documented plan. Define your spine-leaf topology, interconnect density, and the required uplink bandwidth to ensure your new switch sits comfortably within the existing fabric. Gather the necessary optics and cables, verify the data-center power availability, and confirm a suitable management network for out-of-band access. Safety reminders, such as proper ESD precautions and adherence to rack-mount practices, should be followed to protect the equipment and personnel.

Step 1 — Rack and rack-rail preparation: Verify that the rack is rated for the anticipated load and that rails are compatible with your rack depth. Align the switch with the rack rails, ensuring proper ventilation around the unit to promote airflow and prevent thermal throttling.

Step 2 — Physical installation: Secure the switch to the rack with the appropriate screws or rails provided by the manufacturer. Confirm that all front-panel ports remain accessible for cable management and future maintenance. Route power and data cables in an orderly fashion to minimize interference and ease future audits.

Step 3 — Power and cooling: Connect the redundant power supplies to appropriately rated power sources. Ensure power cords are properly plugged, and verify that cooling fans are functioning. Monitor the data center environment to maintain recommended ambient temperatures and airflow for optimal performance and component longevity.

Step 4 — Network cabling: Install the 40/100 GbE uplinks and any required downlinks using QSFP28 optics and appropriate cables. Label ports clearly and maintain consistent cabling conventions to simplify troubleshooting and future changes. Where possible, separate management traffic from data-plane traffic to reduce contention and improve reliability.

Step 5 — Management access and initial configuration: Connect to the switch through a console or management interface and set up a secure management IP, DNS and NTP servers, and basic authentication. Configure a hostname, management VLAN, and access controls to limit administrative access. Enable NX-OS features necessary for your environment, such as feature NX-OS, and prepare for integration with your orchestration platform or Cisco DNA Center. Save the initial configuration, and establish a baseline for ongoing monitoring.

Step 6 — Validation and monitoring: Verify that the switch boots correctly and that all ports come online with expected speed and duplex settings. Run basic connectivity tests between hosts and endpoints, verify routing or switching paths, and confirm that telemetry streams are providing data to your monitoring systems. Schedule routine health checks, firmware updates, and security policy reviews to maintain ongoing reliability and performance.

Step 7 — Integration with the broader fabric: If your data center uses EVPN-VXLAN or a similar fabric, configure the necessary overlay networks, VXLAN VNIs, and EVPN control plane settings. Validate multi-tenant isolation and QoS policies to ensure that each tenant or workload receives the required bandwidth and isolation. Finally, validate integration with your SDN or automation stack, confirming that API access and automation playbooks function correctly in a live environment.

Frequently asked questions

  • Q: Is the N9K-C9332D-GX2B suitable for data-center leaf-spine architectures? A: Yes, it is designed to work within leaf-spine fabrics, offering high-density 40/100 GbE ports, scalable uplinks, and fabric-aware features that support dense, scalable data-center deployments.
  • Q: Does it support EVPN-VXLAN for multi-tenant environments? A: Yes, EVPN-VXLAN and related virtualization features are supported to enable secure micro-segmentation and flexible multi-tenant networking.
  • Q: What management options are available for day-to-day operations? A: NX-OS provides a mature CLI, REST APIs, and streaming telemetry for automated monitoring, orchestration, and integration with management platforms such as Cisco DNA Center and third-party tools.
  • Q: How is high availability achieved in this switch? A: The switch offers redundant hot-swappable power supplies and fans, along with resilience features like fast failover, hardware fault isolation, and deterministic behavior to minimize downtime.
  • Q: Can this switch be integrated with existing Cisco or third-party SDN solutions? A: Yes, it is designed to interoperate with Cisco automation ecosystems as well as standard southbound APIs for integration with SDN controllers and orchestration platforms.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed