Description
Cisco UCS 9508 Network Equipment Chassis
The Cisco UCS 9508 Network Equipment Chassis stands as a pillar of modern data center design, delivering enterprise-grade reliability, scalability, and streamlined operations in a single, modular platform. Engineered for high-density compute environments, this chassis is part of Cisco’s Unified Computing System (UCS) ecosystem, combining server blades, networking, and storage interconnects into a cohesive infrastructure. Built to support large-scale deployments, it enables rapid provisioning, policy-based automation, and centralized management through Cisco UCS Manager, helping IT teams reduce manual tasks and accelerate time-to-value. The 9508 chassis is designed to thrive in demanding workloads—from virtualization and cloud services to data-intensive analytics—while prioritizing energy efficiency, fault tolerance, and straightforward lifecycle management. Whether you’re expanding a private cloud, upgrading a data center rack, or supporting a multi-tenant environment, the Cisco UCS 9508 Network Equipment Chassis provides a resilient foundation for scalable, predictable performance.
- Modular, scalable architecture for flexible compute and I/O — The Cisco UCS 9508 chassis is built to accommodate diverse blade configurations and interconnect options, enabling organizations to scale compute density and network capacity as workloads evolve. Its modular design simplifies expansion, allowing you to add blades, mezzanine cards, and interconnects without overhauling the core infrastructure. With a focus on unified fabric, you can optimize bandwidth, reduce latency, and streamline cabling, creating a more efficient data center footprint. This level of flexibility supports evolving business needs, from seasonal spikes to long-term growth, while maintaining consistency in policy-driven deployment across the UCS ecosystem.
- Unified management with Cisco UCS Manager — At the heart of the Cisco UCS experience is UCS Manager, which delivers policy-based automation and centralized control over compute, storage, and networking. The 9508 chassis integrates seamlessly with UCS Manager, enabling service profiles that abstract individual server configurations from physical hardware. This approach accelerates blade provisioning, simplifies firmware management, and ensures consistent performance across blades and racks. With unified visibility into health, firmware compliance, and resource utilization, IT teams can enforce standards, reduce human error, and achieve reliable, repeatable deployments at scale.
- High availability and fault tolerance — Reliability is built into the 9508 chassis through redundant power supplies, hot-swappable cooling fans, and fault-tolerant design principles. Redundancy minimizes downtime during maintenance or component failure, while proactive health monitoring detects issues before they impact workloads. The chassis supports non-disruptive maintenance, enabling technicians to replace components without interrupting critical operations. This level of resilience is essential for mission-critical applications, SLA-driven services, and environments where continuous availability is non-negotiable.
- Efficient cooling and power management for data center efficiency — Efficient airflow and intelligent power management help reduce energy consumption without sacrificing performance. The chassis is engineered to optimize cooling, balance workload distribution, and minimize waste heat, contributing to lower total cost of ownership over the equipment lifecycle. By consolidating compute and network interconnects in a single platform with robust power redundancy, organizations can achieve better thermal management, easier cabling, and improved energy efficiency across their UCS deployment.
- Security, compliance, and lifecycle management — Cisco UCS emphasizes secure operational practices, with features that support role-based access, firmware integrity, and auditable change control. The 9508 chassis integrates into the broader security and compliance framework of the UCS ecosystem, enabling consistent policy enforcement, secure boot processes, and streamlined firmware updates. Lifecycle management becomes more predictable with centralized monitoring, automated health checks, and end-to-end visibility, helping organizations maintain peak performance while reducing operational risk.
Technical Details of Cisco UCS 9508 Network Equipment Chassis
- Specifications unavailable in this listing. For precise, up-to-date details, consult the official vendor documentation or product datasheet.
- Model: Cisco UCS 9508 Network Equipment Chassis
- Power: Redundant power supply options with hot-swappable modules designed for continuous operation
- Cooling: Redundant, hot-swappable cooling fans to support high-availability workloads
- Management: Native integration with Cisco UCS Manager for policy-based automation and centralized control
- Interconnect: Flexible I/O and fabric options to support scalable network architectures and diverse workload requirements
How to install Cisco UCS 9508 Network Equipment Chassis
- Plan the installation by confirming rack space, weight load, grounding requirements, and compliance with data center power and cooling provisions. Ensure the rack is level, properly grounded, and compatible with 19-inch rack standards.
- Power down and de-energize the installation area as required. Use appropriate personal protective equipment (PPE) and electrostatic discharge (ESD) precautions when handling hardware components.
- Mount the Cisco UCS 9508 chassis securely in the rack, using all mounting rails and screws specified by the manufacturer. Check that the chassis is firmly seated and level to prevent vibration and ensure proper airflow.
- Connect redundant power cords to a suitable power distribution unit (PDU) or power source. Ensure power cables are rated for the chassis and that circuit protection aligns with site electrical standards.
- Connect network and management interconnects as required. Attach fabric interconnects and management networks following the designed topology, color-coding cables when possible to simplify future maintenance.
- Power on the chassis and verify initial hardware status. Access Cisco UCS Manager to identify the chassis, apply firmware baselines, and establish service profiles for blades and interconnects as needed.
- Install blades or modules into the chassis and assign them to service profiles. Validate that all components are recognized, firmware is consistent, and health sensors report normal status.
- Perform a basic functional test, including power cycling components if necessary, and confirm connectivity to the network fabric. Document the configuration changes and monitor the system for the initial 24–72 hours to ensure stable operation.
Frequently asked questions
- Q: What is the Cisco UCS 9508 Network Equipment Chassis used for? A: It is a modular chassis designed to host Cisco UCS B-Series blades and related interconnects, enabling scalable, policy-driven data center deployments with unified management and high availability.
- Q: Is the 9508 hot-swappable? A: Yes. Key components such as power supplies and cooling fans are hot-swappable to support non-disruptive maintenance and continuous availability.
- Q: How does UCS Manager help with this chassis? A: UCS Manager provides centralized, policy-based automation, service profiles, firmware management, and health monitoring, reducing manual configuration and ensuring consistent deployments across the infrastructure.
- Q: Can this chassis support multiple fabric interconnect configurations? A: Yes. The chassis is designed to work with various fabric interconnect configurations and scalable I/O options to suit different data center topologies and workloads.
- Q: What should I consider for warranty and support? A: Warranty and support options vary by vendor and region. Check with the authorized seller for the exact terms, coverage windows, and service levels associated with your purchase.
Customer reviews
Showing - Of Reviews