Description
Digi One SP IA Terminal Server
The Digi One SP IA Terminal Server is a compact, purpose-built bridge between legacy serial devices and modern Ethernet networks. Designed for industrial environments, this single-port device server brings the simplicity and reliability of serial communication into a scalable, IP-based workflow. With its RS-232/422/485 DB-9 serial interface and native Ethernet connectivity, it enables seamless data exchange, remote monitoring, and easy integration of field devices, PLCs, sensors, and instrumentation into your automation ecosystem.
- One RS-232/422/485 DB-9 serial port lets you connect a wide range of industrial equipment without the need for adapters or custom cabling.
- Ethernet networking provides fast, reliable access to data from serial devices across the plant floor or over remote networks.
- Simple, scalable integration with TCP/IP and UDP enables flexible data transport, remote control, and telemetry for industrial applications.
- Web-based configuration and management deliver an intuitive setup experience, including remote monitoring, status checks, and secure administration.
- Compact, rugged design supports space-constrained installations and is suitable for DIN rail mounting or desktop deployment in harsh environments.
Technical Details of Digi One SP IA
- Serial Port: 1 x DB-9 port supporting RS-232, RS-422, and RS-485
- Ethernet Interface: 1 x RJ-45 Ethernet port (10/100 Mbps)
- Network Protocols: TCP/IP and UDP for flexible data transport and integration with existing network infrastructure
- Management: Web-based configuration interface for easy setup, status monitoring, and management from any networked device
- Security and Access: Secure remote management options through standard network protocols to protect device access and data
- Power and Form Factor: Compact unit designed for reliable operation in industrial environments, suitable for space-limited installations
how to install Digi One SP IA
- Plan your installation by identifying the serial device you’ll connect and the network addressing you’ll use (DHCP or static IP).
- Mount the Digi One SP IA in a suitable enclosure or on a DIN rail if supported by your installation environment, ensuring adequate ventilation and protection from dust and moisture.
- Connect the serial device’s DB-9 connector to the Digi One SP IA’s RS-232/422/485 port, matching the device’s electrical interface and voltage levels.
- Attach the Ethernet cable from the Digi One SP IA’s RJ-45 port to your network switch or router to enable IP connectivity and access to the device over TCP/IP.
- Provide power to the unit using the approved DC power source, and power it on. Allow the device to complete its startup sequence.
- Discover or assign an IP address. If your network supports DHCP, the Digi One SP IA may obtain an IP automatically; otherwise, configure a static IP that fits your network scheme.
- Open a web browser and connect to the device’s IP address to access the web-based management interface. Log in with the default credentials and immediately change them to secure access.
- Configure the serial-to-network mapping. Define how the serial port data is transported over TCP/IP (for example, setting up a TCP server or client, and mapping a specific port or endpoint for data exchange).
- Fine-tune serial settings such as baud rate, parity, data bits, stop bits, and flow control to match the connected device. Save the configuration and apply the changes.
- Test data flow by sending and receiving data between the serial device and a connected application over the network. Verify reliability, latency, and error handling, and adjust timeouts or retry parameters as needed.
- Document the configuration for future maintenance, including IP address, port mappings, and access credentials. Regularly monitor status through the web interface to ensure ongoing reliability.
Frequently asked questions
-
Q: What is the Digi One SP IA Terminal Server used for?
A: It serves as a serial-to-Ethernet bridge, enabling devices with RS-232/422/485 serial interfaces to connect to an Ethernet network for remote access, data collection, and integration into IT/OT systems. -
Q: How many serial ports does it have?
A: It features a single RS-232/422/485 DB-9 serial port. -
Q: What networking capabilities does it support?
A: It provides Ethernet connectivity (10/100 Mbps) and supports standard networking protocols such as TCP/IP and UDP for flexible data transport. - Q: How do I configure the device?
- A: Use the built-in web-based management interface accessed via the device’s IP address to configure serial parameters, network settings, and data mappings. Save and apply changes for immediate effect.
- Q: Can I mount this device in a DIN rail?
- Q: Is remote management supported?
-
Q: What kind of environments is this device suited for?
A: It is designed for industrial automation and control environments where serial devices need reliable network connectivity, data logging, and remote access.
A: Yes, the Digi One SP IA is designed for compact installation and is suitable for DIN rail mounting in industrial settings.
A: Yes, remote management is supported through secure web-based access and standard network protocols, enabling monitoring and configuration from a central location.
Customer reviews
Showing - Of Reviews