Eaton 11.5kW 208-240V 3PH Monitored PDU - LX Interface, Gigabit, 48 Outlets, IEC 309 16/20A Red 360-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA

Tripp Lite by EatonSKU: 5363516

Price:
Sale price$1,061.78

Description

Eaton 11.5kW 208-240V 3PH Monitored PDU with LX Interface

The Eaton 11.5kW Monitored PDU is built for high-density data centers, enterprise server rooms, and demanding IT environments where uptime, efficiency, and intelligent power management are non-negotiable. Designed to deliver robust three-phase distribution with precise outlet monitoring, this PDU combines powerful electrical performance with enterprise-grade management features. Its LX interface leverages Gigabit networking to give IT administrators real-time visibility into voltage, current, and power quality for every outlet, enabling proactive maintenance and capacity planning. With 48 outlets, a compact 0U footprint, and a tall 1.8-meter height, it maximizes rack density while maintaining clean routing and easy access for service and upgrades. The unit’s red IEC 309 connectors and a 360-415V input range are tailored for modern data centers that demand flexible power distribution across multiple circuits, making it an ideal solution for data-intensive workloads, virtualization, and mission-critical applications.

  • Premium 11.5kW power capacity supports dense server rows, blade enclosures, and network gear without compromising safety or performance, ensuring stable power delivery to critical equipment even during peak load conditions.
  • Three-phase output at 208-240V with a resilient 360-415V input range provides scalable, balanced power distribution, reducing voltage variation on sensitive equipment and improving overall system reliability.
  • Monitored PDU with LX interface and Gigabit connectivity offers granular, outlet-level monitoring, real-time alerts, and remote management capabilities for fast fault isolation and precise energy analytics across the data center.
  • 48 outlets arranged in a compact 0U footprint with an 1.8-meter height profile delivers high rack density and clean cabling, enabling efficient cooling and straightforward maintenance in crowded racks and cabinets.
  • Integrated LCD display, long 1.8-meter cord, IEC 309 red connectors, and TAA-compliant design deliver clear on-site visibility, flexible installation options, and procurement compatibility for government and large enterprises alike.

Technical Details of Eaton 11.5kW 208-240V 3PH Monitored PDU - LX Interface, Gigabit, 48 Outlets, IEC 309 16/20A Red 360-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA

  • Power rating: 11.5 kW for high-density IT deployments and scalable power distribution across racks and rows.
  • Output voltage: 208-240 V, 3-phase, suitable for modern servers, storage, and network devices that require stable three-phase distribution.
  • Input voltage range: 360-415 V AC, 3-phase (IEC 309 Red connectors), designed for data centers with higher line-to-line voltages and varied utility feeds.
  • Outlet count: 48 outlets to support a large number of devices in a single PDU, reducing the need for multiple power strips and simplifying cable management.
  • Interface and management: LX interface with Gigabit Ethernet enables remote monitoring, outlet-level metering, SNMP integration, and status alerts for proactive maintenance.
  • Monitoring capabilities: real-time measurements of current, voltage, power, and load for each outlet, helping operators balance workloads and prevent overloading circuits.
  • Display and visibility: built-in LCD provides local status, configuration screens, and quick diagnostics without relying solely on network connectivity.
  • Cord and footprint: 1.8-meter power cord; 0U footprint with a 1.8-meter height, designed to fit a wide range of 19-inch racks and cabinet configurations.
  • Connector and color: IEC 309 red connectors designed for specific high-current circuit feeds and enhanced safety in data centers.
  • Compliance: TAA-compliant to meet government procurement requirements and enterprise purchasing policies.

How to install Eaton 11.5kW 208-240V 3PH Monitored PDU

Installing this PDU is a straightforward process when conducted with standard data-center practices. Begin by verifying the electrical service and confirming that the available circuits match the 360-415V, 3-phase input requirements. Ensure that the rack or cabinet has adequate support and ventilation for the 1.8-meter height, and prepare cable management routes to keep the 1.8-meter cord free of kinks and accessible for maintenance. Follow these general steps to install the Eaton PDU efficiently and safely:

  • Power down and isolate the rack area to prevent accidental contact with live circuits during installation. Gather the necessary tools and PPE before beginning work.
  • Mount the PDU in a suitable rack space, selecting a location that allows clear access to the LCD display and outlet panels. The 0U footprint helps maximize rack density while the tall height accommodates the distribution needs of multiple devices.
  • Connect the 360-415V three-phase power feed to the IEC 309 input connectors. Ensure correct phase alignment and secure all connectors with the appropriate locking hardware, following local electrical codes and safety standards.
  • Route and label cables to the 48 outlets, avoiding tangling or over-constraining any single conduit. Use color-coded identifiers for critical devices and ensure proper strain relief to protect cords from wear.
  • Power on the system and configure the LX interface: set up IP addressing, SNMP community strings, alert thresholds, and outlet-level monitoring preferences. Validate LCD display readings and confirm that all outlets report correct voltage and load data after devices boot.

Once installed, monitor the PDU continuously via the LX interface, ensuring that load balances stay within safe margins across all phases. Regularly review per-outlet metering to anticipate capacity expansion needs, optimize cooling, and keep critical workloads running without interruption. Routine firmware updates and security patches should be applied through the Gigabit interface to maintain compatibility with your network management tools and ensure resilient operations in your data center environment.

Frequently asked questions

  • Q: What is a Monitored PDU?

    A monitored PDU provides real-time data on voltage, current, power, and sometimes temperature for each outlet. This enables proactive capacity planning, faster fault isolation, and improved uptime by allowing administrators to identify overloaded circuits before problems occur.

  • Q: What does the LX interface offer?

    The LX interface offers network-enabled power management with Gigabit connectivity. It supports remote configuration, outlet-level metering, alerts, SNMP integration, and centralized monitoring, making it ideal for centralized data-center management and integration with existing DCIM tools.

  • Q: How many outlets are in this Eaton PDU?

    The unit provides 48 outlets, designed to support a large number of devices in a compact footprint. This helps reduce the need for additional power strips and simplifies cable management in dense deployments.

  • Q: What does 360-415V input mean for installation?

    360-415V input indicates the PDU is configured for three-phase electrical feeds common in data-center environments. This range allows it to be paired with high-voltage feeds, enabling efficient distribution to downstream devices while maintaining stability and minimizing voltage drop across long runs.

  • Q: Is the PDU compliant with procurement requirements?

    Yes. The Eaton PDU is TAA-compliant, making it suitable for government procurement and other organizations that require Trade Agreements Act compliance.

  • Q: What does 0U footprint and 1.8 m height mean for deployment?

    The 0U footprint means the PDU can be mounted in racks without occupying traditional horizontal space, maximizing rack density. The 1.8-meter height is typical for tall, distributed power solutions in large data centers, designed to support multiple sockets and outlets while aligning with standard cabinet dimensions.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed