Eaton 1U Logic Control Unit for Robotic Fiber Panel System

Tripp Lite by EatonSKU: 5505912

Price:
Sale price$13,377.83

Description

Eaton 1U Logic Control Unit for Robotic Fiber Panel System

Power, precision, and performance converge in the Eaton 1U Logic Control Unit designed specifically for the Tripp Lite NRFP Robotic Fiber Panel System. The NRFP-LCU-1 serves as the centralized intelligence hub that coordinates signaling, control logic, and system timing to ensure smooth, repeatable operation of robotic fiber handling. This compact 1U unit is purpose-built to fit into standard 19-inch rack environments, making it ideal for data centers, labs, manufacturing floors, and controlled industrial spaces where space is at a premium but reliability is non-negotiable. By consolidating control responsibilities into a single unit, operators gain easier management, faster diagnostics, and improved system uptime for high-throughput fiber panel applications. The kit includes a logic control unit, a signaling cable that attaches to NRFP-500MM-CP or NRFP-500SM-CP Robotic Fiber Panel System, and a ground cable that connects to facility ground, delivering a complete, ready-to-install solution for streamlined robotic fiber panel control. With robust connectors and an emphasis on durable, shielded cabling, the NRFP-LCU-1 is engineered to withstand demanding environments while maintaining precise control over robotic fiber operations. The result is a more dependable fiber panel workflow, reduced downtime, and the ability to scale your robotic fiber system as operations grow. Whether you are deploying a new NRFP system or upgrading an existing installation, this control unit provides the core functionality needed to synchronize movement, signaling, and feedback across multiple panels, enabling tighter process control and higher quality outcomes in fiber handling tasks.

  • Seamless NRFP integration: The NRFP-LCU-1 is designed to work with the Tripp Lite NRFP Robotic Fiber Panel System, including the NRFP-500MM-CP and NRFP-500SM-CP configurations, delivering synchronized control and reliable signaling for coordinated panel operation.
  • Compact 1U rack-mount form factor: Engineered to fit neatly into standard 19-inch racks, the unit preserves valuable rack space while providing centralized logic control for the entire NRFP system, ideal for data centers, labs, and production floors.
  • Centralized control for improved reliability: By housing the core control logic in a single unit, operators benefit from streamlined management, consistent signaling, and reduced likelihood of misconfigurations across multiple robotic fiber panels.
  • Includes essential cabling for quick setup: The kit ships with a signaling cable that connects the NRFP-LCU-1 to NRFP-500MM-CP or NRFP-500SM-CP panels, plus a ground cable to tie the equipment to the facility grounding system for safety and noise mitigation.
  • Rugged, purpose-built for industrial environments: The unit is designed with robust connectors and shielded cabling to minimize interference and withstand demanding conditions typical in manufacturing and data-center floor deployments.

Technical Details of Eaton 1U Logic Control Unit for Robotic Fiber Panel System

  • Model: NRFP-LCU-1
  • Included components: Logic control unit, signaling cable for NRFP-500MM-CP or NRFP-500SM-CP, ground cable
  • Compatibility: Tripp Lite NRFP Robotic Fiber Panel System, including NRFP-500MM-CP and NRFP-500SM-CP configurations
  • Form factor: 1U rack-mountable
  • Mounting: Standard 19-inch equipment rack mounting compatibility

How to install Eaton 1U Logic Control Unit for Robotic Fiber Panel System

  • Plan and prepare: Identify a suitable spot within a standard 19-inch rack with adequate clearance for cables and ventilation. Ensure power is available in the rack and that the NRFP system components are ready for integration.
  • Mount the NRFP-LCU-1: Secure the logic control unit in a 1U rack space using appropriate mounting hardware. Align the unit with existing rails and fasten securely to prevent vibration or movement during operation.
  • Connect signaling cable: Attach the signaling cable included with the NRFP-LCU-1 to the NRFP-500MM-CP or NRFP-500SM-CP Robotic Fiber Panel System. Ensure a clean, firm connection to minimize signal loss or intermittent communication.
  • establish grounding: Connect the ground cable to the facility grounding system as directed, providing a solid earth reference to reduce electrical noise and improve safety for the NRFP system.
  • Power up and validate: Apply power to the NRFP-LCU-1 and the NRFP panels. Perform initial system checks, verify signaling between the control unit and panels, and run any required commissioning steps as outlined in the NRFP system documentation to confirm proper operation before commencing production tasks.

Frequently asked questions

  • What is the Eaton 1U Logic Control Unit for Robotic Fiber Panel System? It is the centralized logic and signaling controller for the Tripp Lite NRFP Robotic Fiber Panel System, packaged as a 1U rack-mount unit that coordinates operations across NRFP panels using an included signaling cable and a dedicated ground connection.
  • Which NRFP configurations are supported? The unit ships with a signaling cable that connects to NRFP-500MM-CP or NRFP-500SM-CP Robotic Fiber Panel System, indicating compatibility with these NRFP configurations and enabling synchronized control for those setups.
  • What advantages does centralizing control provide? Centralized control simplifies installation, reduces potential configuration errors, improves coordination between robotic panels, and can lead to more reliable performance and faster troubleshooting in complex fiber-handling tasks.
  • What mounting space does it require? The NRFP-LCU-1 is designed for 1U rack mounting in standard 19-inch racks, making it suitable for data centers, labs, and industrial floors where rack space is at a premium.
  • What cables are included and what is required for setup? The kit includes a signaling cable for connection to NRFP-500MM-CP or NRFP-500SM-CP and a ground cable for facility grounding. Depending on the broader NRFP system deployment, additional cabling or interfaces described in the NRFP manuals may be required for full integration.
  • Is there any software or configuration utility needed? The provided description emphasizes hardware components (logic control unit, signaling cable, ground cable). For software or configuration utilities, refer to the NRFP system manuals or Eaton’s product documentation for guidance on any required setup steps beyond basic hardware installation.
  • Where can I find more technical specifications? Technical specs beyond what is listed here (including power requirements, environmental ratings, and connector details) are typically found in the official NRFP-LCU-1 documentation or the NRFP system manuals supplied by the manufacturer or distributor. Check the retailer’s product page or contact support for the most complete specifications.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed