Eaton 2-post Rack-mount Installation Kit For Select 1u 5p Ups Systems And Select

EatonSKU: 3622343

Price:
Sale price$137.58

Description

Eaton 2-Post Rack-Mount Installation Kit For Select 1U 5P UPS Systems And Select

The Eaton 2-post rack-mount installation kit is engineered to securely integrate select 1U 5P UPS systems into standard 2-post server racks, delivering a clean, professional, and highly reliable deployment. Designed with Eaton’s proven durability and engineering discipline, this kit helps IT teams minimize downtime and simplify ongoing maintenance by providing a stable, tool-efficient mounting solution. Whether you are building out a data center, a retail edge environment, or a corporate server room, this rack-mount kit ensures your UPS sits exactly where it should—secure, accessible, and optimized for airflow. The 2-post mounting approach preserves rack real estate while keeping the UPS within easy reach for service, diagnostics, and quick battery replacements. By integrating the UPS with a robust rack system, you gain improved cable management, reduced strain on power cables, and enhanced overall reliability for mission-critical devices.

  • Secure fit for select Eaton 1U 5P UPS in standard 2-post racks: This installation kit is purpose-built to match Eaton’s 1U 5P UPS footprint, ensuring a precise alignment within a standard 19-inch, 2-post rack. The rails are engineered to provide firm side-to-side stability, minimizing movement during vibration or relocation and preserving the integrity of sensitive UPS connections. By securing the UPS directly to the rack, you eliminate the risk of wobble or misalignment, which can compromise cooling airflow and service access. The result is a dependable, professional installation that’s ready for mission-critical workloads and uptime demands.
  • Versatile mounting with adjustable rails for flexible depth and alignment: The kit features adjustable mounting rails that accommodate a range of rack depths and UPS depths, helping you tailor the installation to your specific enclosure. This versatility is particularly valuable in mixed-rack environments where post spacing or depth can vary between chassis and cabinets. With adjustable rails, you can achieve flush mounting, proper venting, and easy access to the UPS faceplate and rear panel for maintenance without removing the entire enclosure. The result is an unobtrusive, tidy installation that keeps networking and power cables neatly organized and out of the way.
  • Durable construction and corrosion-resistant finish for long-term reliability: Built from sturdy steel with a protective finish, the rack-mount kit is designed to withstand the rigors of data-center operation. The combination of rigid rails, secure mounting points, and high-quality fasteners helps resist wear from repeated maintenance cycles, rack movements, and the routine handling of cables. This durability translates into fewer service interruptions and lower replacement costs over the life of your UPS system, delivering value beyond the initial installation. The robust construction also supports consistent alignment of UPS modules, improving diagnostics and replacement accuracy when service is required.
  • Effortless maintenance and scalable compatibility with existing rack hardware: The kit is designed to work with standard rack hardware and commonly used mounting rails. This compatibility reduces downtime during upgrades or service and simplifies training for IT staff. With clearly labeled mounting points and straightforward assembly, technicians can install, remove, or reposition the UPS quickly, minimizing rack downtime. The kit’s compatibility with select Eaton models plus existing rack infrastructure makes it a practical, scalable choice for growing data centers and edge deployments alike.
  • Improved airflow, accessibility, and organized cable management: A key benefit of proper 2-post mounting is optimized airflow around the UPS unit. The kit ensures adequate clearance around vents and cooling channels, helping to preserve battery efficiency and UPS performance. Integrated cable-management considerations minimize tension on power and data connections, reduce heat buildup, and simplify future upgrades or battery replacements. By keeping cables tidy and components accessible, maintenance tasks—such as battery swaps, firmware updates, or diagnostic checks—are faster and safer for technicians and the equipment they service.

Technical Details of Eaton 2-post Rack-Mount Installation Kit For Select 1U 5P UPS Systems And Select

  • Technical specifications are SKU-dependent; exact dimensions, weight ratings, and mounting compatibility vary by model. For precise figures, consult the official specifications corresponding to the specific SKU or UPC for your 1U 5P UPS and rack configuration.

how to install Eaton 2-post Rack-Mount Installation Kit

  • Step 1: Prepare the rack and UPS. Confirm that your rack is a standard 19-inch, 2-post configuration and that both the UPS and rack-mount kit are compatible. Clear the mounting area, disconnect any load or power connections as required, and lay out all rails, brackets, and fasteners included with the kit.
  • Step 2: Attach mounting rails to the rack posts. Align the rails with the front and rear mounting holes on the rack posts, ensuring level placement. Secure the rails to the posts using the included screws or hardware. Double-check alignment to guarantee a straight, stable mounting surface for the UPS. Tighten hardware to manufacturer-specified torque to avoid loosening during service or transport.
  • Step 3: Mount the UPS onto the rails. With the rails secured, carefully slide the 1U 5P UPS into position along the rails. Engage any retention features or brackets included in the kit to lock the UPS in place. Ensure that the UPS faceplate is accessible for monitoring and that there is adequate clearance for cables and ventilation on all sides.
  • Step 4: Connect cables and power paths. Route power and data cables neatly along the cable-management features of the rails, avoiding sharp bends or tension on connectors. Connect AC input and any required data cables, ensuring proper separation from cooling airflow paths. If applicable, attach any external battery pack interface cables and verify that all connectors are fully seated.
  • Step 5: Finalize installation and verify operation. Recheck all mounting hardware for security, ensure vent clearance, and confirm that the UPS is receiving power. Power up the UPS and perform a basic test of functionality, including self-test or battery discharge test as recommended by Eaton for the specific model. Confirm that alarms and status indicators display correctly and that the UPS is communicating with any connected systems or management software.

Frequently asked questions

  • Q: Is this kit compatible with all Eaton 1U 5P UPS models?
    A: The kit is designed for select Eaton 1U 5P UPS systems. Compatibility depends on the exact UPS model and rack configuration. Always verify compatibility against Eaton’s product documentation for your specific SKU before purchasing or installing.
  • Q: Does the kit include all mounting hardware required for a 2-post rack?
    A: Yes. The installation kit typically includes rails, brackets, and the necessary fasteners needed to secure the UPS to a standard 2-post rack. Some installations may require additional tools or hardware depending on the rack design, so consult the included manual for details.
  • Q: Can I reuse this kit for future UPS replacements?
    A: The kit is designed for select Eaton models and standard 2-post racks. Reuse depends on compatibility with the replacement UPS and the presence of the same mounting footprint. Always verify the new UPS model’s compatibility and mounting requirements with Eaton’s guidelines.
  • Q: Will installing this kit affect UPS warranty or rack warranty?
    A: In most cases, using manufacturer-approved rack-mount kits should not void warranties when installed according to the manufacturer’s instructions. It’s best to confirm with Eaton and your rack vendor to ensure compliance with warranty terms and installation standards.
  • Q: How does rack mounting affect UPS cooling and maintenance access?
    A: Proper rack mounting with spacer and clearance guidelines supports optimal airflow around the UPS and keeps maintenance access straightforward. The kit’s design minimizes shielding of air intake/exhaust paths and provides ready access to connectors and serviceable components for routine maintenance and battery swaps.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed