Eaton 2-Post Rack-Mount Installation Kit for Select UPS Systems

EatonSKU: 3410248

Price:
Sale price$141.87

Description

Eaton 2-Post Rack-Mount Installation Kit for Select UPS Systems

The Eaton 2-Post Rack-Mount Installation Kit is the ideal solution for mounting select UPS systems into a 2-post server rack with ease and efficiency. Designed for durability and operational effectiveness, this installation kit helps IT environments maximize rack space, simplify maintenance, and ensure reliable power protection with a secure, industry-standard mounting platform that fits most 2-post racks. Built to withstand busy data centers and office server rooms, the kit supports streamlined deployment and long-lasting performance for critical power infrastructure.

  • Compatibility and fit: Engineered to support select Eaton UPS models in standard 19-inch 2-post racks, providing accurate alignment and a secure, vibration-resistant mount. This kit is designed to work with common rack configurations found in data centers and IT closets, enabling quick integration without additional adapters or custom hardware.
  • Rugged construction for reliability: Crafted from high-strength steel and finished with a durable powder coating, the rails and brackets resist corrosion and daily wear. The robust build helps protect the UPS against shocks and vibrations while maintaining clean, stable installation over time.
  • Easy installation and fast setup: The kit includes all necessary rails, brackets, and fasteners, plus clearly labeled hardware to simplify mounting. With a design that minimizes the need for specialized tools, IT teams can deploy the UPS quickly, reducing downtime and service windows.
  • Optimized cable management and airflow: Integrated cable guides and routing channels keep power and data cables orderly, which improves airflow around the UPS and surrounding equipment. A tidy installation reduces cable strain and enhances cooling efficiency in dense rack environments.
  • Secure mounting and long-term performance: The kit provides balanced weight distribution and secure attachment points, ensuring stable operation even in busy data centers. By delivering a solid, rack-friendly mounting solution, it supports dependable UPS performance and simplified ongoing maintenance.

Technical Details of Eaton 2-Post Rack-Mount Installation Kit for Select UPS Systems

  • Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference

how to install Eaton 2-Post Rack-Mount Installation Kit

To install the Eaton 2-Post Rack-Mount Installation Kit, begin by verifying compatibility with your UPS model and confirming that your data center rack is a standard 2-post, 19-inch-wide system. Unpack the kit and lay out all components, checking that rails, brackets, and fasteners are present. Attach the rack rails to the two-post rack posts at the desired height, using the provided screws and washers, and ensure the rails are level and square for proper UPS alignment. Once the rails are secured, slide the UPS unit onto the rails so that the mounting brackets align with the rails’ slots, then fasten the UPS to the brackets using the included hardware. Route power and communication cables cleanly through the cable guides, ensuring there is ample clearance for airflow around the enclosure. Finally, power up the UPS and verify that status indicators, alarms, and connected peripherals communicate correctly with the rack-mounted setup. If cable strain or misalignment is detected, adjust the rails or re-seat the unit to restore stability and ensure optimal cooling.

Frequently asked questions

Q: Is this kit compatible with all Eaton UPS models?
A: The kit is designed for select Eaton UPS systems that are suitable for 2-post rack installations. Always check the product page for compatibility notes and confirm that your UPS model matches the supported range before purchasing.

Q: What rack size and type does the installation kit fit?
A: This kit is intended for standard 19-inch, 2-post server racks. It provides rails and brackets that align with common rack spacings and mounting hole patterns used in most data centers and IT closets.

Q: Do I need special tools to install the kit?
A: Most installations are designed for straightforward assembly with common tools. The kit includes all required mounting hardware, and the step-by-step guidance helps technicians complete the job efficiently without specialized equipment.

Q: Will installing this kit affect UPS warranty or service?
A: When installed according to the manufacturer’s instructions and using the supplied hardware, the kit typically remains compliant with standard warranty terms. Always review the warranty documentation for your specific UPS model and installation method.

Q: Are there any maintenance tips after installation?
A: Periodically inspect the rack mounting for tightness of screws, ensure cable management remains orderly, and verify that airflow around the UPS is unobstructed. Regular checks help maintain performance and extend the life of both the UPS and the mounting kit.

Q: Can this kit be reconfigured or re-mounted in a different rack?
A: Yes. The modular design supports reconfiguration in compatible 2-post racks, making it easier to relocate UPS units as your data center layout evolves. Carefully follow the installation steps again when moving to a new rack.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed