Eaton 23kW 220-240V 3PH Switched PDU - LX Interface, Gigabit, 30 Outlets, IEC 309 32A Red 380-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA

Tripp Lite by EatonSKU: 5181696

Price:
Sale price$2,051.51

Description

Eaton 23kW 220-240V 3PH Switched PDU - LX Interface, Gigabit, 30 Outlets, IEC 309 32A Red 380-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA

The Eaton 23kW 220-240V 3PH Switched Power Distribution Unit (PDU) is a premier power management solution engineered for demanding data centers, colo facilities, and IT closets. This advanced PDU combines high-capacity power handling with intelligent control, giving you precise load distribution, rapid fault isolation, and real-time visibility into your critical infrastructure. Designed for three-phase systems, it accepts a robust 380–415V input and delivers reliable 220–240V power to connected devices at the rack, enabling optimized performance for dense racks, blade servers, storage arrays, and networking gear. The LX interface with built-in Gigabit Ethernet opens a gateway to proactive monitoring, secure remote management, and automated alerting, so operators can reduce downtime, enhance energy efficiency, and streamline operations without ever leaving the network operations center. The LCD readout provides at-a-glance information on voltage, current, power, and outlet status, while the 1.8 m power cord and 0U footprint ensure a clean, flexible installation in today’s space-constrained data centers. As a TAA-compliant solution, this Eaton PDU aligns with government procurement requirements, offering trusted, enterprise-grade reliability for public sector and regulated environments.

  • High-capacity three-phase power – 23 kW total capacity designed to support dense server and storage workloads, with robust protection and scalable distribution to keep critical systems running smoothly during peak demand. This level of capacity helps data centers maintain service levels while accommodating future growth and equipment refresh cycles.
  • 380–415V input, 220–240V output – Engineered for modern data centers that rely on three-phase power, delivering stable, balanced distribution to outlets and minimizing voltage drop across long cable runs. The PDU’s architecture supports dependable operation of high-performance servers and network devices under load.
  • LX interface with Gigabit Ethernet – A feature-rich management plane that enables remote monitoring, outlet switching, SNMP integration, and real-time alerting. Operators can configure thresholds, collect metrics, and respond to events quickly from the data center floor or the network operations center.
  • 30 outlets with IEC 60309 (IEC 309) 32A red connectors – Safe, high-current distribution ideal for IT equipment that demands reliable power delivery. The switched design permits controlled reboots and load management across outlets, improving maintenance workflows and reducing the risk of cascading outages.
  • Compact 0U footprint with LCD and 1.8 m cord – Space-saving installation that preserves valuable rack real estate while delivering comprehensive visibility through the built-in LCD. A long 1.8 m cord provides flexible routing and easy placement within the rack and adjacent power infrastructure. The unit’s design is optimized for tight racks and crowded data centers, enhancing scalability and organization.

Technical Details of Eaton 23kW 220-240V 3PH Switched PDU

  • Power rating: 23 kW total capacity for demanding workloads and peak usage scenarios.
  • Input voltage: 380–415V AC, 3-phase connection suitable for data-center power distribution.
  • Output voltage: 220–240V distribution to outlets, optimized for server and network equipment.
  • Outlets: 30 outlets configured to support high-current devices with IEC 60309 (IEC 309) 32A red connectors.
  • Management interface: LX interface with Gigabit Ethernet for remote monitoring, configuration, and control of outlet switching (where supported).
  • Display: Integrated LCD for real-time metrics, status indicators, and fault alerts at the rack edge.
  • Cord length: 1.8 m power cord to simplify installation and cable routing.
  • Mounting footprint: 0U rack-mount design to maximize rack density and preserve space for IT gear.
  • Compliance: TAA-compliant for government procurement and standardized purchasing requirements.

How to Install Eaton 23kW 220-240V 3PH Switched PDU

  • Step 1: Plan your rack layout and verify that the installation area can accommodate a 0U PDU with a 1.8 m cord run. Confirm that the facility’s power source is a three-phase 380–415V supply that can deliver sufficient current for the PDU plus connected equipment.
  • Step 2: Mount the PDU securely in the 0U slot of the rack using the included hardware. Ensure the unit is level and firmly fastened to withstand the load of connected devices and any vibration from equipment operation.
  • Step 3: Connect the PDU’s 1.8 m power cord to the appropriate 380–415V three-phase power source or distribution panel. Follow all local electrical codes and safety procedures, and use a properly rated power cable with suitable connectors for your facility.
  • Step 4: Attach devices to the 30 outlets, distributing loads across phases to balance current and minimize hotspots. Label critical loads for quick identification and monitoring, and verify that the connected equipment does not exceed outlet or overall PDU ratings.
  • Step 5: Power up the PDU and access the LX interface. Configure remote monitoring, alert thresholds, and outlet switching (if supported by your model). Validate network connectivity via the Gigabit Ethernet port and use the LCD to verify voltage, current, and outlet status during initial commissioning.

Frequently asked questions

  • Q: What environments is this PDU best suited for?
    A: It is ideal for data centers, colocation facilities, and enterprise IT rooms that require high-capacity, monitored, and switchable power distribution for three-phase infrastructure and dense rack deployments.
  • Q: How does the LX interface enhance management?
    A: The LX interface provides remote monitoring, outlet control, SNMP integration, and alerting over Gigabit Ethernet, allowing operators to manage power, respond to faults, and optimize energy usage without direct on-site intervention.
  • Q: Can I use this PDU with a 220–240V IT rack?
    A: Yes. The device is designed to take 380–415V three-phase input and distribute 220–240V to connected outlets, aligning with common IT equipment voltage requirements in many regions.
  • Q: Is a 0U footprint compatible with standard server racks?
    A: Yes. The 0U footprint is specifically designed to maximize rack space while delivering essential power management capabilities at the rack edge.
  • Q: Is this model compliant with government procurement standards?
    A: Yes. The PDU is TAA-compliant, making it suitable for purchase under applicable government programs and contracts.