Description
Eaton 3.7kW Single-Phase Switched PDU - LX Interface for 208/230V Outlets (20 C13 & 4 C19), 0U, C20/L6-20P, TAA
Designed for demanding IT environments, the Eaton 3.7kW Single-Phase Switched PDU with LX Interface delivers intelligent power distribution, precise control, and comprehensive visibility for modern data centers and server rooms. This compact, 0U rack-mount PDU provides reliable protection and efficient power management for dense rack deployments, enabling you to optimize uptime, reduce energy waste, and simplify appliance management. With a versatile outlet mix (20 C13 and 4 C19) and a robust LX management interface, you can remotely monitor, control, and automate power to critical equipment, keeping your infrastructure responsive and resilient.
- High-capacity single-phase power distribution — 3.7 kW of reliable power at 208/230V to support blade servers, storage arrays, high-density networking, and other essential IT devices without overloading circuit infrastructure.
- LX interface for remote control and visibility — The LX management platform enables outlet-level switching, alarm thresholds, scheduled maintenance windows, and real-time power metrics to help maximize uptime and efficiency.
- Flexible outlet configuration for diverse gear — 20 IEC C13 outlets paired with 4 IEC C19 outlets accommodate a wide range of servers, storage, and network gear in a single, organized rack footprint.
- 0U rack-mount design for dense deployments — A slim, space-saving form factor fits seamlessly into standard 19-inch racks, reducing cable clutter and increasing rack density without sacrificing performance.
- TAA-compliant, rugged construction — Built for IT and industrial environments with government procurement in mind, ensuring durability, reliability, and long service life in challenging conditions.
Technical Details of Eaton 3.7kW Single-Phase Switched PDU - LX Interface
- Power rating: 3.7 kW
- Input/connection: C20/L6-20P configuration (configurable to match installation requirements)
- Output voltage: 208/230V
- Outlet configuration: 20 x IEC C13, 4 x IEC C19
- Form factor: 0U rack-mount
- Interface: LX for remote control, monitoring, and automation
- Compliance: TAA-compliant
- Applications: IT and industrial environments requiring reliable power distribution with remote management
How to Install Eaton 3.7kW Single-Phase Switched PDU - LX Interface
Installing the Eaton LX-switched PDU is straightforward and designed to minimize downtime during deployment. Start by preparing the rack area: ensure adequate clearance for airflow, confirm the rack structure can support 0U mounting, and verify that the local electrical supply matches the PDU’s input configuration. Power down equipment within the rack to prevent unexpected surges during installation. Remove any panel coverings if present and locate the 0U slot in the rack where the PDU will be mounted. Use the included mounting hardware to secure the PDU to the rack rails, ensuring a stable, level installation with proper cable pathing to enable efficient airflow.
Next, connect the PDU’s input power to the appropriate power source. Depending on your configuration, attach either a C20 inlet or an L6-20P power cord to the PDU and connect the other end to a suitable power distribution circuit that matches your data center’s electrical design. Once the PDU is securely powered, begin distributing power to your IT equipment. Practice tidy cabling by grouping power cords and routing them to the IEC C13 and C19 outlets on the PDU, then connect servers, storage devices, and networking gear as needed.
With the physical installation complete, access the LX management interface to configure remote power controls. Establish network connectivity, assign an IP address or participate in your organization’s DHCP scheme, and tailor alert thresholds for event notifications such as overcurrent, high temperature, or outlet faults. Create outlet groups to simplify mass power actions, schedule maintenance windows to minimize downtime, and enable power metering to track energy consumption over time. Finally, perform a staged power-on test: verify each outlet’s on/off capability, confirm alert delivery, and validate accurate reporting of energy use and outlet status. Document the configuration for future audits and maintenance.
Routine maintenance of the PDU is simple: periodically check for firmware updates for the LX interface, inspect cabling for wear, and confirm that the PDU remains securely mounted. Regularly reviewing power consumption data helps you optimize workloads, reallocate devices to balance loads, and identify aging equipment before it impacts uptime. This proactive approach can yield meaningful energy savings and support a more sustainable data center operation.
Frequently asked questions
- What outlets are included? The PDU provides 20 IEC C13 outlets and 4 IEC C19 outlets to support a wide range of servers, storage devices, and network gear within a single rack.
- What voltage does it output? It delivers 208/230V, which is standard for many data center installations and compatible with a broad array of IT equipment.
- What is the form factor? The PDU has a 0U footprint for compact, space-efficient rack installations, helping maximize rack density and improve cable management.
- What is the LX interface? LX is Eaton’s remote management interface that enables outlet-level control, real-time monitoring, alerting, and automation to support proactive power management.
- Is this PDU compliant with procurement standards? Yes, the unit is TAA-compliant, making it suitable for government and enterprise deployments that require compliance with Trade Agreements Act requirements.