Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface, 208/230V Outlets (20 C13 & 4 C19), L6-30P, 0U, TAA

Tripp Lite by EatonSKU: 4999551

Price:
Sale price$720.06

Description

Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface

The Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface delivers reliable, scalable power distribution for critical IT environments. Designed to provide real-time visibility and robust control, this PDU is built to help data centers and industrial racks optimize energy use, shrink downtime, and simplify administration. With a 5.5 kW rating, 208/230V outlets, and LX platform integration, it ensures your equipment stays powered, protected, and performing at peak efficiency.

  • Real‑time monitoring and alerts that empower proactive management of power usage, cooling needs, and potential overloads across the rack.
  • LX Platform Interface for centralized monitoring, policy‑driven control, and seamless integration with Eaton’s data center management ecosystem.
  • Flexible outlet configuration featuring 20 C13 outlets and 4 C19 outlets to support a diverse mix of servers, storage devices, and network gear.
  • Compact 0U form factor paired with a 208/230V input/output design, maximizing rack density without compromising reliability or safety.
  • TA A-compliant, rugged construction built for demanding IT environments and industrial applications, delivering dependable power distribution in a compact footprint.

Technical Details of Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface

  • Power rating: 5.5 kW
  • Voltage: 208/230V outlets and system operation
  • Outlets: 20 x C13, 4 x C19 for versatile device support
  • Input: L6-30P connector for reliable, high‑quality power intake
  • Form factor: 0U rack-mount design to preserve valuable rack space
  • Platform: LX Platform Interface for advanced monitoring, diagnostics, and control
  • Compliance: TAA (Trade Agreements Act) compliant for government and enterprise deployments
  • Monitoring capabilities: real-time metrics for voltage, current, power, and energy usage (per‑PDU awareness, with potential for outlet-level visibility depending on model)

How to install Eaton 5.5kW Single-Phase Monitored PDU with LX Platform Interface

Installing this PDU is a straightforward process designed to minimize downtime and maximize reliability. Follow these steps to ensure a safe, correct setup that unlocks full monitoring capabilities and optimal power distribution:

  • Plan the rack placement. Confirm there is adequate clearance for airflow around the PDU and access to its connection points. Ensure the 0U footprint aligns with the rack’s available space and that the L6-30P power circuit matches your facility’s electrical distribution.
  • Power down equipment temporarily if you are upgrading an existing rack 구성. Disconnect the existing power feeds and prepare to replace or install the new PDU in the intended rack space.
  • Mount the PDU in the rack. Align mounting holes with the rack rails and secure the unit firmly. Verify there is no strain on the L6-30P input connector or outlet cables once installed.
  • Connect the input power. Plug the L6-30P power cord into a compliant, rated 208/230V circuit. Ensure the circuit breaker and wiring are appropriate for the PDU’s maximum load to avoid nuisance trips.
  • Connect outlets to devices. Route server, storage, and network equipment cables to the 20 x C13 outlets and 4 x C19 outlets. Maintain good cable management to preserve airflow and simplify future maintenance.
  • Enable LX Platform Interface. Connect the PDU to your network as required by the LX Platform Interface guidelines. This connection will enable real‑time monitoring, alerting, and remote management from the Eaton LX ecosystem or compatible management systems.
  • Configure monitoring and alerts. Use the LX Platform Interface to set thresholds, notification channels, and alarm policies. Map outlets as needed for granular visibility and rapid fault isolation.
  • Test and verify. Power on the devices and verify that power is delivered to all connected equipment. Confirm that monitoring metrics populate correctly in the LX interface and that alerts trigger as configured.
  • Document the setup. Record the PDU’s location, circuit details, outlet mappings, and LX configuration for future maintenance and audits.

Frequently asked questions

  • What is a monitored PDU, and how does the LX Platform Interface enhance its value? A monitored PDU provides real-time electrical metrics such as voltage, current, power, and sometimes outlet-level data. The LX Platform Interface enables centralized monitoring, management, and integration with Eaton’s broader ecosystem, allowing proactive alerts, policy-based control, and streamlined data center operations.
  • How many outlets does this PDU have, and what outlets are they? It features 20 C13 outlets and 4 C19 outlets, designed to support a mix of servers, storage, and network equipment in a single 0U footprint.
  • Is this PDU compatible with 208V and 230V environments? Yes. The PDU is designed for 208/230V operation, with a corresponding L6-30P input connector designed for reliable, high‑voltage distribution.
  • What are the benefits of the LX Platform Interface for data centers or industrial IT deployments? The LX platform provides centralized visibility, alerting, and control across PDUs, enabling faster issue detection, energy optimization, and easier capacity planning, especially in multi-rack or multi-site environments.
  • Is this Eaton PDU compliant with government procurement requirements? Yes. The unit is TAA compliant, making it suitable for government and enterprise deployments where Trade Agreements Act compliance is required.