Eaton 5.5kW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (16 C13), L6-30P Input, 12 ft. (3.66 m) Cord, 2U Rack-Mount, TAA

EatonSKU: 2032639

Price:
Sale price$949.05

Description

Eaton 5.5kW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (16 C13), L6-30P Input, 12 ft. Cord, 2U Rack-Mount, TAA

Discover unparalleled control and visibility over your IT power infrastructure with this high-performance switched PDU. Engineered for data centers, server rooms, and demanding network closets, the Eaton 5.5kW single‑phase Switched PDU combines robust power distribution with enterprise-grade remote management. Designed to protect uptime, optimize energy use, and simplify administration, this LX‑interface PDU gives you precise, outlet-level control and real-time insights right at your fingertips.

  • Power at your fingertips: Each of the 16 C13 receptacles can be controlled individually, letting you turn outputs on, off, recycle outlets, or lock them out to prevent unauthorized power cycling. With outlet-level control, you can protect critical equipment during maintenance, automate reboot sequences for servers and storage, and minimize the impact of faults across the data center. The LX interface presents intuitive, granular management that reduces mean time to repair and increases overall system reliability. In addition to on/off control, you can schedule power cycles and apply policies that align with maintenance windows, firmware upgrades, and performance-driven load shedding, all from a single, centralized console.
  • Real‑time visibility for smarter decisions: Monitor live electrical conditions and per-outlet load to balance rack power and prevent overloads. The PDU delivers essential metrics such as voltage, current, and power consumption, enabling proactive capacity planning and energy optimization. With proactive alerts and event logs, your team can respond to anomalies before they escalate, maintaining service levels and protecting expensive IT gear. This level of visibility is especially valuable in multi-rack environments, where small variances can compound into reliability concerns without proper monitoring.
  • Rugged, rack-ready design for data centers and IT rooms: A compact 2U form factor houses a durable metal enclosure built to withstand the rigors of busy data centers. The 12‑foot (3.66 m) cord provides flexible installation options, whether you’re mounting the unit in a dense rack layout or reaching power sources from different locations in the room. With 208/230V outlets and a secure L6‑30P input, this PDU is tuned for typical enterprise circuit configurations and can seamlessly integrate with a wide range of IT equipment, from blades to enterprise servers and network devices.
  • Government and enterprise procurement ready: TAA-compliant and designed to meet strict sourcing requirements, this PDU is a solid choice for federally funded projects, higher education labs, and public sector deployments. The combination of a long cord, a standardized LX management interface, and reliable build quality makes it suitable for large-scale rollouts where consistent performance and supplier transparency are essential.
  • Effortless integration and operation: The LX interface supports remote management across the network, enabling IT teams to monitor, configure, and control power remotely. Whether you’re coordinating a data center consolidation, expanding a campus IT footprint, or optimizing a remote site, this PDU integrates with standard DCIM and monitoring tools, streamlining administration and reducing manual intervention. The practical benefits include faster troubleshooting, safer maintenance windows, and scalable power governance across multiple racks and rooms.

Technical Details of Eaton 5.5kW Single-Phase Switched PDU

  • Power rating: 5.5 kW
  • Phase: Single-phase
  • Outlets: 16 C13 receptacles rated for 208/230V operation
  • Input: L6-30P input connector for robust, server-grade power intake
  • Cord length: 12 ft (3.66 m)
  • Mounting: 2U rack-mount form factor for compact data-center deployment
  • Interface: LX management interface for outlet-level control and remote monitoring
  • Monitoring: Real-time output power, voltage, and current per outlet with alerting capabilities
  • Compliance: TAA compliant for government and procurement requirements

How to install Eaton 5.5kW Switched PDU

  • Plan the placement: Determine the most efficient rack position to minimize cable clutter and maximize air flow. Confirm there is a suitable power source with a 208/230V circuit and an available L6-30P receptacle to connect the PDU's input.
  • Rack preparation: Slide the PDU into the designated 2U space in the rack, aligning mounting rails. Secure the unit with screws or mounting hardware appropriate for your rack system to ensure stable, vibration-free operation.
  • Connect the power input: Plug the 12 ft cord from the PDU input into the L6-30P supply. Ensure the power source can deliver the required current for 5.5 kW of load and that the circuit is protected by appropriate overcurrent protection.
  • Connect devices: Attach servers, storage, and network devices to the 16 C13 outlets. Distribute critical equipment across multiple outlets to optimize resilience and load balancing.
  • Configure LX interface: Access the LX management interface through the supported network connection. Configure outlet permissions, set power-up/power-down sequences, create event alerts, and enable monitoring thresholds to match your data center policies. Save configurations and perform a controlled power cycle to verify that the PDU responds as expected.
  • Test and validate: Power on devices in a staged sequence, monitor per-outlet load, verify alerting, and confirm that remote management commands (on, off, recycle, lock-out) operate correctly. Document the configuration for future maintenance and audits.

Frequently asked questions

  • Q: What does the LX interface do?
    A: The LX interface provides outlet-level control and remote monitoring capabilities. It lets you turn individual outlets on or off, recycle power, apply lock-out protections, and view real-time power metrics from a single management pane.
  • Q: How many outlets does this PDU have?
    A: It features 16 C13 outlets for flexible distribution of 208/230V equipment across a single rack unit footprint.
  • Q: What input does this PDU require?
    A: The unit uses an L6-30P input connector, suitable for standard 208/230V enterprise circuits, enabling efficient power delivery to high-demand IT gear.
  • Q: Is this PDU suitable for government procurement?
    A: Yes. The model is TAA compliant, making it appropriate for government and public-sector purchasing in supported regions.
  • Q: Can I monitor power usage remotely?
    A: Yes. The LX interface supports remote monitoring of output power consumption, voltage, and current per outlet, helping you manage capacity and enforce power policies without on-site visits.