Eaton 5.7kW 3-Phase Monitored PDU, 120V Outlets (36 5-15/20R), 208V L21-20P, 10 ft. (3.05 m) Cord, 0U Vertical, TAA

Tripp Lite by EatonSKU: 2864233

Price:
Sale price$617.13

Description

Eaton 5.7kW 3-Phase Monitored PDU

The Eaton 5.7kW 3-Phase Monitored PDU is designed for mission-critical IT environments where uptime, efficiency, and real-time visibility matter. This high-density power distribution unit delivers robust, dependable power to demanding data centers, server rooms, and edge deployments. With a compact 0U vertical footprint, a long 10-foot cord, and a versatile 208V L21-20P input paired with 36 outlets of 120V 5-15/20R, it provides a scalable solution that grows with your IT workloads. The PDU’s monitored design means you gain continuous insight into load, voltage, and environmental performance, enabling proactive management, faster fault detection, and smarter capacity planning. Additionally, the Eaton Monitored PDU is designed to meet stringent procurement requirements with its TAA compliance, ensuring it’s suitable for government and regulated industries. Engineered for reliability, this PDU helps you reduce mean time to repair (MTTR) and protect your critical equipment from power disturbances, while delivering energy-management capabilities that can lower operating costs in busy data centers.

  • Powerful 5.7 kW, 3‑phase distribution: Supports dense IT deployments and multi-rack configurations, delivering consistent, scalable power to servers, storage, switches, and networking gear while preserving headroom for growth and peak demand.
  • 36 x 5-15/20R outlets at 120V: Abundant receptacles accommodate a wide range of devices in a single, organized power strip arrangement, simplifying wiring and reducing the need for additional power strips in the rack.
  • 208V L21-20P input: Optimized for three-phase data-center power infrastructure, delivering efficient distribution and balanced loading across phases for improved performance and reduced heat.
  • 0U vertical mounting with 10 ft cord: Ultra-compact design minimizes rack footprint while providing flexible routing options, enabling clean cable management and easy integration into existing rack layouts.
  • Monitored, real-time visibility: Built-in monitoring sensors deliver live data on load, voltage, and outlet status with alerting to help prevent overloads, maintain SLAs, and optimize energy usage across the IT stack.

Technical Details of Eaton 5.7kW 3-Phase Monitored PDU

  • Power capacity: 5.7 kW rated, designed for reliable distribution to high-density IT equipment in data centers and server rooms.
  • Outlets: 36 x 5-15/20R outlets operating at 120V, suitable for standard enterprise equipment, and providing ample headroom for diverse device inventories.
  • Input voltage and configuration: 208V L21-20P input, three-phase configuration to balance loads and improve efficiency in modern data-center power systems.
  • Cord length: 10 ft (3.05 m) cord, enabling flexible placement within racks or adjacent cabinets and easier routing through densely cabled environments.
  • Mounting: 0U vertical rack-mount design that optimizes rack space and simplifies installation in standard 19-inch racks without sacrificing accessibility or airflow.
  • Compliance and procurement: TAA-compliant, suitable for government and regulated procurement programs, delivering confidence in compliance for contract-based purchases.
  • Monitoring and management features: Real-time load monitoring, outlet-level status, and voltage sensing with alerting to support proactive capacity planning, incident response, and energy management strategies.
  • Safety and reliability: Engineered with rugged construction and standards-based electrical safety to help protect connected devices and minimize unexpected outages caused by power disturbances.
  • Energy efficiency: Provides visibility into power usage and load distribution, enabling smarter scheduling, workload balancing, and potential cost savings in continuous-operation environments.

How to install Eaton 5.7kW 3-Phase Monitored PDU

  • Prepare the rack: Ensure the rack frame is rated for 0U devices, verify clearance for cabling, and plan the routing of power and data connections to minimize interference and maximize cooling efficiency.
  • Position the PDU: Slide the 0U vertical PDU into the rear of the rack along the rails, aligning mounting holes with the vertical mounting posts. Secure the unit using the appropriate screws or mounting hardware provided by Eaton or your rack vendor.
  • Connect the power input: Connect the 208V L21-20P input to the data-center power source, ensuring the supply is de-energized during installation. Confirm that the three-phase connection is balanced to optimize load distribution.
  • Route and connect outlets: Route outlet cables cleanly and connect devices to the 36 x 5-15/20R 120V receptacles. Maintain tidy cable management to promote airflow and simplify future maintenance or reconfigurations.
  • Configure monitoring: Power up the PDU and access its management interface (via local display, web interface, or compatible management software). Set up alert thresholds for load, voltage, and temperature, and enable alerts through your preferred channel (email, SNMP traps, or other supported methods) to receive timely notices of anomalies.
  • Verify operation and balance: Confirm that all outlets are live, check that the monitored data reflects current loads across phases, and verify that any alarms or notifications trigger as expected. If needed, rebalance connected devices to optimize efficiency and prevent localized overloading.
  • Document and validate: Record the final configuration, cable routes, and monitored parameters for future audits and maintenance cycles. Periodically review alert logs and compare them against historical data to identify trends and opportunities for optimization.

Frequently asked questions

  • Q: What outlets does the PDU provide? A: It features 36 x 5-15/20R outlets at 120V, designed to accommodate a wide range of servers, switches, storage devices, and other equipment typically deployed in data centers and enterprise IT rooms.
  • Q: What voltages and phases are supported? A: The PDU is a 3-phase unit with a 208V L21-20P input, enabling balanced three-phase distribution for efficient power delivery in modern data-center deployments. The outlets operate at 120V for compatibility with common IT gear.
  • Q: How long is the power cord? A: The PDU comes with a 10-foot (3.05 m) cord, providing flexible routing options within standard rack and cabinet configurations.
  • Q: Is this PDU compliant with government procurement standards? A: Yes. This model is TAA-compliant, meeting sourcing requirements for government and regulated industries.
  • Q: What monitoring features are included? A: It provides real-time load monitoring, outlet-level status, and voltage sensing, along with alerting capabilities to help you maintain uptime and optimize energy usage across your IT infrastructure.
  • Q: How can I manage alerts and data from the PDU? A: Configure the PDU’s monitoring interface to send alerts via email or integrate with your existing network management software using supported protocols, enabling proactive maintenance and centralized visibility.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed