Eaton 7 kVA External Wall Mountable Maintenance Bypass Switch

EatonSKU: 2795435

Price:
Sale price$852.59

Description

Eaton 7 kVA External Wall Mountable Maintenance Bypass Switch

Protect your critical loads with a purpose-built bypass solution. The Eaton 7 kVA External Wall Mountable Maintenance Bypass Switch is designed to offer a safe, reliable bypass path for UPS systems, enabling smooth maintenance without interrupting power to essential equipment. Built for data centers, server rooms, and other mission-critical environments, this switch provides a compact, wall-mounted solution that combines ease of installation with trusted Eaton engineering.

  • The core benefit of a maintenance bypass switch is uninterrupted service during UPS maintenance. This Eaton 7 kVA model gives technicians a clean transfer path from normal operation to bypass, allowing routine servicing, battery replacements, or UPS upgrades to occur without shutting down critical infrastructure, thus minimizing downtime and preserving service levels for businesses and operations that rely on continuous power.
  • Wall-mountable design for efficient space use and flexible installation. This external wall mountable construction keeps the switch accessible for maintenance personnel, reduces clutter around electrical cabinets, and enables you to position the bypass unit in convenient proximity to UPS equipment and essential load centers. Its compact footprint makes it ideal for data centers, telecom rooms, or industrial facilities with limited space.
  • Improved reliability and safety for critical environments. By providing a dedicated bypass path, the Eaton 7 kVA switch helps isolate the UPS and load during maintenance, protecting personnel and equipment. The robust construction and tested switching mechanism are designed to withstand repeated operation, delivering consistent performance when transferring loads between main power and maintenance bypass paths.
  • Intuitive operation and integration with Eaton systems. This maintenance bypass switch is designed to complement Eaton UPS architectures, supporting straightforward installation alongside compatible modules and accessories. Its design emphasizes reliability for routine maintenance windows and emergency planning, making it a smart addition to facility power protection strategies.
  • Cost-effective protection with professional-grade robustness. Although compact, this 7 kVA bypass switch delivers a dependable solution for small to mid-size power protection scenarios, helping facilities maintain uptime and extend equipment life. The external wall-mountable format reduces the need for complex rack space and simplifies future scaling or relocation within data centers or server rooms.

Technical Details of Eaton 7 kVA External Wall Mountable Maintenance Bypass Switch

  • Power rating: 7 kVA
  • Mounting: External wall mountable design for easy installation near critical loads
  • Function: Maintenance bypass switch to provide a safe bypass path for UPS systems
  • Application: Suitable for data centers, server rooms, and other facilities requiring uninterrupted power during maintenance
  • Manufacturer: Eaton

how to install Eaton 7 kVA External Wall Mountable Maintenance Bypass Switch

  • Plan the placement: Choose a convenient location near your UPS and the protected load, ensuring there is clear access for operators and adequate space for wiring and labeling. Verify that the wall can support the weight and that mounting surfaces meet any local electrical codes.
  • Power down safely: Before installation, de-energize the UPS system and the load to prevent accidental shock or equipment damage. Use appropriate lockout/tagout procedures as required by your facility’s safety policies.
  • Mount the enclosure: Secure the bypass switch to the wall using the approved mounting hardware. Ensure the unit is level and firmly attached to a stable surface to withstand daily operation and any movement during maintenance.
  • Connect input and output: Route conductors from the UPS output to the switch input terminals, and connect the switch output to the protected load. Follow the manufacturer’s wiring diagrams and label all conductors clearly to facilitate future maintenance.
  • Verify connections and safety: Double-check all connections for tightness and proper insulation. Ensure the enclosure doors or panels are closed and secured, and that any fault indicators or status lights are visible and functioning appropriately.
  • Initial testing: With the system de-energized, test the bypass operation by moving the switch to bypass and then back to normal operation, observing load response and monitoring indicators. Confirm that power transfer occurs smoothly without arcing or unexpected interruptions.
  • Final labeling and documentation: Record installation details, wiring schematics, and testing results in your facility maintenance logs. Provide operators with clear operating instructions and safety guidelines for ongoing use.

Frequently asked questions

  • Q: What is the purpose of an external wall mountable maintenance bypass switch? A: It provides a safe, controllable bypass path for UPS systems, allowing maintenance or battery replacement without interrupting critical loads, thus minimizing downtime.
  • Q: Is this bypass switch compatible with all UPS brands? A: This model is designed to integrate with Eaton UPS systems; compatibility with other brands may require adapters or additional engineering review. Always consult Eaton documentation or a qualified electrician for installation guidance.
  • Q: Can I install the Eaton 7 kVA bypass switch myself? A: Installation should be performed by licensed electrical personnel following local codes and safety procedures. The wall-mount design is intended to simplify installation in data centers and similar environments, but proper wiring and safety practices are essential.
  • Q: What maintenance scenarios benefit most from this switch? A: Routine UPS maintenance, battery replacement, inverter servicing, and any downtime-necessary work where the ability to isolate the load from the UPS while keeping power to critical equipment is advantageous.
  • Q: Does the product come with a warranty? A: Warranty details are typically provided by Eaton and may vary by region or distribution channel. Check the product listing or contact the supplier for the current warranty terms and coverage.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like