Eaton Basic rack PDU, 0U, L14-30P input, 5.76 kW max, 120/240V, 24A, 10 ft cord, Split-phase, TAA compliant, Outlets: (24) 5-20R

EatonSKU: 4220786

Price:
Sale price$950.86

Description

Eaton Basic Rack PDU — 0U, L14-30P Input, 24 x 5-20R, 120/240V, 5.76 kW, 10 ft Cord

Discover reliable, cost‑effective power distribution for demanding data center environments with the Eaton Basic rack PDU. Engineered to fit in tight spaces without compromising performance, this 0U PDU is designed to streamline rack power management for mid‑to large‑scale deployments. Built around a robust form factor and practical receptacle options, it delivers the essential infrastructure your IT equipment needs to stay up, connected, and running smoothly. If your goal is to optimize rack density, simplify cabling, and ensure a steady, predictable power path for servers, storage, and networking gear, the Eaton Basic rack PDU is a proven choice that aligns with modern data center design principles.

  • A slim, space‑saving design that fits into the tight confines of standard server racks, enabling high-density deployments without sacrificing organization or airflow.
  • L14‑30P input supports 120/240V, split‑phase service for reliable, scalable power delivery that matches common data center electrical layouts.
  • 24 × 5‑20R outlets provide broad compatibility for a wide range of IT gear, from front‑end servers to edge devices, while simplifying cable management.
  • Up to 5.76 kW (24 A) of total power at 120/240V ensures capable distribution for rack‑level workloads without overloading individual circuits.
  • TAA compliant for government procurement and enterprise deployments, built to endure the rigors of data center environments and minimize maintenance needs.

Technical Details of Eaton Basic Rack PDU

  • Model: Eaton Basic rack PDU, 0U
  • Input: L14‑30P, 120/240V
  • Power rating: 5.76 kW max
  • Current: 24 A
  • Cord length: 10 ft
  • Outlets: 24 × 5‑20R
  • Phase: Split‑phase
  • Form factor: 0U rackmount
  • Compliance: TAA compliant
  • Applications: Ideal for data centers, server rooms, and network closets requiring dependable power distribution with minimal rack footprint

how to install Eaton Basic rack PDU

Installing the Eaton Basic rack PDU is a straightforward process designed to minimize downtime and fit into standard IT rack ecosystems. Follow these practical steps to ensure a safe, reliable setup that aligns with best practices for data center power distribution.

Step 1: Plan the rack layout and power pathway. Verify that your rack has available space in the 0U area and that your electrical service can accommodate a 30A, 120/240V supply. Consider cable routing, airflow needs, and future growth so that the PDU and connected equipment remain accessible for maintenance and monitoring.

Step 2: Mount the PDU in the rack. Carefully slide the 0U Eaton Basic rack PDU into the back of the rack or the designated power distribution area. Secure it according to your rack manufacturer’s guidelines, ensuring a stable installation that can withstand typical data center movement and vibration.

Step 3: Route the input power. Connect the 10 ft input cord to a suitable L14‑30P power source or power distribution curb that matches the PDU’s 120/240V split‑phase specification. Confirm that the circuit breaker and wiring support at least 24 A to prevent nuisance tripping and to maintain continuous uptime for connected equipment.

Step 4: Organize and label the outlets. Plan the wiring layout to minimize cross‑cable clutter and to facilitate maintenance. Use cable management tools to guide and secure cords entering the 24 × 5‑20R receptacles, and label each circuit for quick identification during servicing or capacity planning.

Step 5: Power up and verify. With all connections secure, apply power and check that all outlets are delivering voltage. Confirm that connected devices boot correctly and monitor for stable operation. If your environment requires it, perform a functional test by loading a representative subset of outlets to ensure even distribution of power and to detect any imbalance early.

Maintenance tip: Periodically inspect the PDU for signs of wear, ensure cords remain securely seated, and verify that airflow around the unit remains unobstructed. This basic vigilance helps sustain the reliability Eaton is known for in data center environments.

Frequently asked questions

  • What does 0U mean? 0U refers to a zero‑width footprint in the rack, meaning the PDU does not occupy any vertical rack unit space. This allows you to maximize rack density and allocate space for your servers, switches, and storage devices while still benefiting from centralized power distribution.
  • What outlets are provided? The PDU features 24 × NEMA 5‑20R outlets, offering broad compatibility with common IT equipment used in data centers and server rooms.
  • What type of input plug is used? The PDU uses a NEMA L14‑30P input connector, designed for 120/240V split‑phase service and up to 30A, which supports robust, data‑center‑grade power delivery.
  • Is this PDU compatible with government procurement? Yes. The Eaton Basic rack PDU is TAA compliant, aligning with procurement standards for government agencies and other regulated environments.
  • Can I upgrade or monitor power usage with this PDU? This Basic PDU is designed for reliable distribution with essential functionality. It provides dependable outlets and power delivery, but monitoring features may require a more advanced PDU model with built‑in metering or management capabilities.
  • Why choose a basic PDU like this? For organizations prioritizing cost efficiency, space savings, and straightforward power distribution, a basic rack PDU delivers reliable, scalable outlet management without extra complexity or cost associated with advanced monitoring features.