Description
Eaton Basic Rack PDU, 0U, L5-30P Input, 24x 5-20R, 2.88 kW, 100-127V, 24A, 15 ft Cord, Single-Phase
Power reliability is essential for critical IT infrastructure, and Eaton’s Basic rack PDU delivers the dependable distribution you need in a compact, cost‑effective package. Designed as part of the ePDU Value line, this unit focuses on delivering high quality and reliability for the most important power loads while keeping installation simple. Its lightweight construction and 0U footprint make it easy to mount in standard 19‑inch racks, freeing valuable rack space for servers, networking gear, and storage appliances. With a 24‑outlet configuration and a generous 15‑foot cord, you gain flexible placement options within the cabinet or adjacent rows, ensuring proximity to devices and reducing clutter in cable pathways. If you’re upgrading a data center, edge rack, or communications closet, this Eaton Basic PDU provides a practical, scalable solution that blends robust electrical performance with straightforward operation.
- High-capacity distribution: 2.88 kW maximum, supporting up to 24 devices at 100–127V with a 24A current rating, ideal for servers, switches, storage arrays, and network gear in small to mid-sized racks.
- Input and phase: L5-30P input on a single-phase configuration, designed for reliable connection to common commercial power circuits while delivering steady, clean power to attached equipment.
- Outlet configuration: (24) 5-20R receptacles provide familiar, universal outlets that accommodate a wide range of IT devices, enabling flexible connectivity within the rack.
- Footprint and cord length: 0U mounting footprint and a 15‑ft power cord offer maximum rack space efficiency and deployment flexibility, reducing the need for awkward cable runs and enabling cleaner cable management.
- Performance and reliability: Built to support critical loads with consistent power delivery, the Eaton Basic PDU helps minimize downtime and maintenance concerns in data centers, server rooms, and network closets.
Technical Details of Eaton Basic rack PDU
- Model: Eaton Basic rack PDU (0U)
- Input: L5-30P, 100–127V, single-phase
- Maximum power: 2.88 kW
- Current rating: 24A
- Outlets: (24) 5-20R
- Cord length: 15 ft
- Mounting: 0U, 19-inch rack-compatible
- Phase: Single-phase
- Construction: Lightweight, robust design designed for reliability in data center environments
How to install Eaton Basic rack PDU
- Prepare the rack space by ensuring the 19‑inch cabinet is clean and accessible, with adequate clearance for cable management and service access.
- Position the 0U PDU in the intended rack location, aligning with standard mounting rails so that the outlets are reachable from the front of the cabinet.
- Secure the PDU to the rack using appropriate mounting hardware for 19‑inch enclosures; ensure the unit is firmly fastened to prevent movement during maintenance or airflow adjustments.
- Connect the PDU’s L5-30P input to a compatible power source using the supplied cord, confirming that the supply circuit provides 100–127V and supports up to 24A. Ensure that the power source is switched off during connection and testing.
- Distribute devices across the (24) 5-20R outlets, grouping power‑critical equipment on dedicated outlets where possible to optimize load balance and ease future maintenance.
- Route and organize cables to maintain clear airflow and minimize tangling; label circuits and outlets for quick identification during troubleshooting or expansion.
- Power on the rack and verify that all connected devices receive power. Test each outlet group to confirm proper operation and monitor for any unusual heat or audible indicators that could signal an issue.
- Document the installation with the date, model, load estimates, and outlet allocations to support future capacity planning and preventive maintenance.
Frequently asked questions
-
Q: What does 0U mean for this PDU?
A: 0U indicates a zero‑unit height within a standard 19‑inch rack, meaning the PDU occupies no rack units vertically. This compact footprint preserves valuable space for IT equipment and simplifies cabling within the cabinet.
-
Q: How many outlets does this PDU have and what type are they?
A: The unit provides 24 outlets, all of which are 5‑20R receptacles designed to accommodate a broad range of IT equipment with reliable power delivery.
-
Q: What is the input plug, and what voltage does it support?
A: The PDU uses an L5‑30P input plug and supports 100–127V on a single‑phase power supply, delivering up to 24A with a maximum power rating of 2.88 kW.
-
Q: Is this PDU suitable for data centers and network closets?
A: Yes. Its lightweight, compact 0U design, paired with a 24‑outlet configuration and 15‑foot cord, makes it ideal for data centers, server rooms, edge deployments, and network closets where space and reliability are priorities.
-
Q: How do I install and mount the Eaton Basic rack PDU?
A: Install it in a standard 19‑inch rack with appropriate mounting hardware, connect the L5‑30P input to a compatible power source, distribute devices across the outlets, and route cables for clean airflow. Always power down equipment during installation and verify operation after wiring is complete.