Description
Eaton Basic Rack PDU – 2U, 2 x L6-30P Input, 4.99 kW, 230 V, 24 A, 0 ft Cord, Horizontal Rack-Mount
The Eaton Basic Rack PDU is a dependable, space-saving power distribution solution designed for data centers, server rooms, and network closets that demand reliable, tidy power management. This 2U, horizontal ePDU configuration provides two NEMA L6-30R outlets and two L6-30P inputs, delivering up to 4.99 kW of power at 208–240 V. Built to fit in standard racks, it helps you balance loads, reduce wiring complexity, and stay within budget while supporting critical IT equipment with consistent, clean power delivery. With its compact footprint and rugged rack-mount design, this PDU is ideal for businesses seeking a cost-effective, straightforward power distribution option without compromising reliability or safety.
- Compact 2U, horizontal rack-mount design with durable construction for reliable data-center power distribution.
- Two L6-30P input connectors and two L6-30R outlets, supporting a total up to 4.99 kW (approximately 208–240 V, up to 24 A) for high-density rack applications.
- 0 ft cord means you provide the power cord on site to match your installation, enabling flexible cabling to fit your existing power infrastructure and regional electrical standards.
- Single-phase operation with 208–240 V input, designed to simplify provisioning in facilities that standardize on L6-30 power distribution for servers, storage, and networking gear.
- TAA compliant construction makes it suitable for government, education, and other regulated environments while delivering robust performance and straightforward maintenance.
Technical Details of Eaton Basic Rack PDU
- Model: Eaton Basic rack PDU
- Height: 2U
- Output outlets: 2 x NEMA L6-30R
- Input: 2 x NEMA L6-30P
- Maximum power: 4.99 kW (approximately 4990 W)
- Voltage: 208–240 V AC
- Current rating: 24 A
- Cord: 0 ft (no fixed power cord included)
- Phase: Single-phase
- Orientation: Horizontal rack-mountable
- Compliance: TAA compliant
how to install Eaton Basic Rack PDU
Installing the Eaton Basic Rack PDU is a straightforward process designed for rapid deployment in standard 19-inch racks. Begin by selecting a secure, accessible location in your rack that provides adequate airflow and clearance for front-to-back cooling. Use the provided mounting hardware to secure the 2U unit to the rack rails, ensuring it is level and stable. Because this PDU uses 0 ft cord, you should prepare compatible power cords that match your facility’s electrical system and the L6-30P input connectors. Route the power cables carefully to minimize tension and avoid contact with moving rack components or sharp edges. Once mounted, connect each L6-30P input to your power source(s) following local electrical codes and your data-center policies. After power sources are connected, plug your IT equipment into the two L6-30R outlets, distributing the load to prevent overloading any single outlet or circuit. Verify that the total connected load does not exceed the 24 A rating and that the overall system remains within the 208–240 V range. If your rack includes monitoring or management features, enable any available port monitoring or environmental sensors to track voltage, current, and load balance in real time. Finally, perform a quick check to confirm all devices receive stable power and that there is no overheating or unusual noise from the PDU or connected equipment. Regularly inspect cables and connections as part of ongoing maintenance to ensure long-term reliability and efficient power distribution for the rack.
Frequently asked questions
- What is the input configuration for this Eaton Basic Rack PDU?
- Answer: It uses two L6-30P input connectors, allowing flexible connection to your power sources in a single-phase 208–240 V environment.
- How many outlets does it provide and what type are they?
- Answer: It provides two L6-30R outlets (NEMA L6-30R) for connected equipment at 208–240 V.
- What is the maximum power capacity?
- Answer: The PDU supports up to 4.99 kW (approximately 4990 W) at 208–240 V, with a 24 A current rating.
- Is the PDU corded or cord-free?
- Answer: This model features a 0 ft cord, meaning you must supply your own appropriate power cords to match your installation and local electrical codes.
- Is this PDU compliant with government procurement standards?
- Answer: Yes, it is TAA compliant, suitable for government, education, and other regulated environments.
- What mounting orientation is supported?
- Answer: The unit is designed for horizontal rack-mount installation, fitting standard 19-inch racks and occupying 2U of rack space.