Eaton Basic Rack PDU HotSwap MBP 2.88 kW max 110-125V 24A Single-Phase PDU

EatonSKU: 2507628

Price:
Sale price$571.98

Description

Eaton Basic Rack PDU HotSwap MBP 2.88 kW max 110-125V 24A Single-Phase PDU

The Eaton Basic Rack PDU HotSwap MBP delivers reliable, scalable power distribution for critical equipment in data centers, server rooms, and edge deployments. Built to meet the demands of modern IT environments, this PDU provides essential power management with a robust 2.88 kW maximum capacity at standard 110–125V inputs, delivering up to 24A of single‑phase current. Designed to work within Eaton’s wider power ecosystem, it integrates seamlessly with FlexPDU configurations and Maintenances Bypass options to support flexible connections, easier maintenance, and improved uptime. This basic rack PDU is optimized for straightforward installation, dependable performance, and efficient cable management—ideal for servers, storage, networking gear, and other critical IT loads that require predictable power delivery and clear visibility into electrical utilization.

In practice, Eaton’s five-function rack power distribution family, including FlexPDU and Maintenances Bypass PDU variants, is engineered to adapt to today’s varied data-center layouts. The Basic Rack PDU with HotSwap MBP capability embodies the core benefits of that portfolio: reliable distribution, modular flexibility, and maintenance-friendly design. The MBP feature enables a safe, controlled bypass path during planned maintenance, helping IT teams minimize downtime and keep essential devices powered while service is performed. For organizations growing their rack infrastructure, this PDU couples with other Eaton devices to deliver a cohesive, scalable solution that supports load balancing, outlet organization, and centralized power monitoring. The result is a resilient, efficient power foundation that aligns with modern data-center standards and expands as your needs evolve.

  • Power capacity and electrical specs:

    The Basic Rack PDU delivers up to 2.88 kW (2,880 watts) of usable power. It operates at 110–125 V AC with a maximum current rating of 24 A, supporting single‑phase configurations that are common in data-center and enterprise environments. This combination provides reliable distribution for a wide range of IT equipment while helping to prevent overload on any single outlet or circuit.

  • HotSwap Maintenances Bypass (MBP) capability:

    The MBP feature adds a maintenance bypass path, allowing technicians to service or replace the PDU without interrupting power to downstream devices. This capability is particularly valuable for minimizing downtime in critical racks, ensuring continuity of operation for servers and network equipment during routine maintenance or component swaps.

  • Flexibility and ecosystem integration:

    Designed to integrate with Eaton’s broader rack-power ecosystem, including FlexPDU modules and various UPS accessories. This connectivity enables flexible wiring options, streamlined reconfiguration, and scalable power provisioning as IT loads grow or change. The PDU’s architecture supports orderly cable management and clear load segmentation, simplifying monitoring and control within complex rack environments.

  • Rugged, rack-ready design:

    Engineered for reliable operation in demanding data-center environments, the PDU features a secure rack-mount form factor and durable construction. Its 19-inch rack compatibility ensures wide acceptance across enterprise and colocation facilities, while its robust build helps withstand daily handling, airflow considerations, and long-term wear.

  • Ease of deployment and management:

    With straightforward mounting, uncomplicated wiring, and clear labeling of outlets, the PDU supports rapid deployment and simple ongoing management. IT teams benefit from predictable power distribution, easier outlet mapping to devices, and improved visibility into electrical utilization for capacity planning and energy efficiency initiatives.

Technical Details of Eaton Basic Rack PDU HotSwap MBP

  • Power rating:

    Up to 2.88 kW (2,880 watts) maximum load, suitable for powering servers, storage, and network gear without overstressing circuits.

  • Input voltage:

    110–125 V AC, aligning with standard data-center power rails and reducing compatibility concerns with common IT equipment.

  • Current rating:

    Maximum 24 A to support typical rack deployments while maintaining headroom for peak IT loads.

  • Phase:

    Single-phase configuration, which is common for many PDU installations and simplifies electrical provisioning.

  • MBP capability:

    HotSwap Maintenances Bypass (MBP) functionality enables maintenance work without interrupting downstream loads, helping to maximize uptime during service events.

How to install Eaton Basic Rack PDU HotSwap MBP

  • Plan and prepare:

    Identify a suitable 19-inch rack location with adequate clearance for airflow and cable management. Confirm compatibility with your rack and any existing UPS or FlexPDU configurations.

  • Mount the PDU:

    Securely mount the PDU in the rack using the provided hardware, ensuring alignment with the front rails for easy access to outlets and status indicators. Verify that all mounting points are stable and the chassis is properly supported.

  • Connect to power:

    Connect the PDU to a 110–125 V AC power source capable of delivering up to 24 A. Adhere to local electrical codes and use appropriate circuit protection as required by your facility’s standards.

  • Route and connect IT loads:

    Distribute IT equipment by plugging devices into the PDU outlets. Keep cables neatly organized to promote airflow, simplify future maintenance, and reduce the risk of accidental disconnections.

  • Power on and verify:

    Power up the rack and verify the PDU indicators, outlet availability, and basic monitoring (if applicable). If maintenance is planned, test the MBP path to confirm that downstream devices remain powered during service operations.

Frequently asked questions

  • Q: What is the Eaton Basic Rack PDU HotSwap MBP?

    A: It is a basic rack-mounted power distribution unit with a hot-swappable Maintenances Bypass (MBP) function. It distributes power to IT equipment while enabling maintenance without interrupting power to downstream loads where possible.

  • Q: What loads can I power with this PDU?

    A: The PDU supports up to 2.88 kW (2,880 watts) at 110–125 V with a maximum current of 24 A, suitable for servers, storage, and networking gear in typical data-center racks.

  • Q: Is this PDU compatible with FlexPDU or other Eaton UPS accessories?

    A: Yes, it is designed to integrate into Eaton’s power ecosystem, including FlexPDU modules and Maintenances Bypass options, to provide flexible, expandable rack power solutions.

  • Q: How do I install and maintain the MBP feature?

    A: Install the PDU per the mounting instructions, and during maintenance, use the MBP path to bypass the PDU for servicing without interrupting downstream loads.

  • Q: What about warranty and service?

    A: Warranty terms vary by region and model; contact Eaton support or your authorized distributor for specifics.