Description
Eaton DB9 RS-232 Relay/Serial Interface Mini-Slot Card for Eaton 5PX G2, 9SX, and 9PX Lithium-ion UPS Systems
The Eaton DB9 RS-232 Relay/Serial Interface Mini-Slot Card is a compact, essential upgrade for any data center or IT environment looking to gain reliable serial signaling and control capabilities from their Eaton UPS fleet. This mini-slot interface enables a precise DB9 RS-232 connection and a relay output that can trigger alerts, scripts, or external devices when UPS events occur. By adding a dedicated serial interface to compatible Eaton UPS models, you can streamline automated shutdowns, remote monitoring, and integration with building management systems, all while keeping your rack space optimized and uncluttered. If you manage Eaton 5PX G2, 9SX, or 9PX Lithium-ion UPS systems, this card delivers a simple, robust enhancement to your power protection strategy.
- Reliable RS-232 serial communication via DB9 connector: This mini-slot card provides a dedicated DB9 RS-232 interface so you can connect servers, application software, or remote management tools that rely on traditional serial signaling. It enables clear, low-latency data exchange for event reporting, alerting, and scripted responses to UPS status changes.
- Compact mini-slot design for easy integration: Designed to slide into Eaton UPS chassis without occupying a large footprint, the interface card preserves valuable rack space and keeps your system tidy. Its form-factor is ideal for deployments that require multiple cards or limited mounting room in dense data environments.
- Broad compatibility with Eaton UPS families: Engineered for compatibility with Eaton 5PX G2, 9SX, and 9PX Lithium-ion UPS Systems. The card is also used with various Eaton models and generations, including 5130, 5PX, 9135, Evolution, Evolution S, EX, MX, MX Frame, and EX RT series, ensuring flexible deployment across mixed environments and upgrade paths.
- Certified for safety, EMC, and energy regulations: The card carries multiple international certifications to support safe operation and regulatory compliance within enterprise environments. Certifications include EN 61000-6-2 (emission/immunity), EN 61000-6-3 (emission/impact in residential and commercial environments), EN 62040-2 (UPS safety), IEC/EN 60950-1 2002 (information technology equipment safety), and CE marking. These attest to reliability in diverse power environments and ease of integration with global facilities standards.
- Supports reliable signaling and automation workflows: By exposing a relay output alongside the serial interface, the card enables automated shutdown sequences, integration with Building Management Systems (BMS), virtualization hosts, and monitoring software. This dual capability helps minimize downtime during power events and ensures consistent, repeatable responses across your infrastructure.
Technical Details of Eaton DB9 RS-232 Relay/Serial Interface Mini-Slot Card
- Interface type: DB9 RS-232 serial connection plus relay signaling output for UPS event control
- Form factor: Mini-Slot card designed for Eaton UPS chassis
- Compatibility: Eaton 5PX G2, 9SX, and 9PX Lithium-ion UPS Systems; used with models including 5130, 5PX, 9135, Evolution, Evolution S, EX, MX, MX Frame, and EX RT
- Certifications: EN 61000-6-2; EN 61000-6-3; EN 62040-2; IEC/EN 60950-1 2002; CE
- Primary benefits: Serial communication for monitoring and control; relay signaling for automated action; compact installation with wide compatibility
How to install Eaton DB9 RS-232 Relay/Serial Interface Mini-Slot Card
Follow these general steps to install the DB9 RS-232 Relay/Serial Interface Mini-Slot Card into a compatible Eaton UPS system. Ensure you have the appropriate tools and that you observe all safety precautions for working with powered equipment.
- Power down and safeguard the UPS: If possible, place the UPS in a maintenance mode or power down according to your IT department’s procedures. Disconnect external loads as required and ensure you follow your organization’s electrical safety guidelines.
- Identify a suitable mini-slot slot: Locate an available mini-slot within the Eaton UPS chassis. Confirm there is no existing interference with adjacent cards and that the backplane can support the interface card.
- Insert the mini-slot card correctly: Align the card according to the slot orientation and firmly seat it into the backplane. Ensure it is securely connected and that any retaining mechanisms are engaged to prevent loosening during operation or transport.
- Connect the RS-232 cable and signal devices: Attach the DB9 RS-232 cable to the card’s DB9 port. Connect the other end of the cable to your server, management workstation, or automation device. If you plan to use the relay output for signaling, connect the relay terminals to the appropriate input or signaling device per your design.
- Configure the UPS and software: Power up the UPS and access the management software or firmware configuration interface. Enable the serial interface for the DB9 port and configure event signaling or data reporting according to your operational requirements. If applicable, set the relay action (alarm, shutdown trigger, etc.) in the UPS software or your automation scripts.
- Test the signaling path: Validate that UPS events (such as low battery, fault, or over-temperature) trigger the appropriate serial messages or relay actions. Run a controlled test to verify that the automation workflow and BMS responses execute as intended.
- Document the configuration for future maintenance: Record the slot location, cable connections, baud rate, parity, and any software-driven rules associated with the interface. This documentation helps with future upgrades or troubleshooting.
- Return to normal operation: Reconnect any loads if previously disconnected and verify that all systems report properly through the serial interface. Ensure that both the UPS and the connected devices recognize and respond to events in real time.
Frequently asked questions
Q: What is the primary purpose of the Eaton DB9 RS-232 Relay/Serial Interface Mini-Slot Card?
A: It provides a dedicated DB9 RS-232 serial interface and a relay signaling output for Eaton UPS systems, enabling automated monitoring, signaling, and control of connected devices and software during power events.
Q: Which Eaton UPS models support this mini-slot card?
A: The card is designed for Eaton 5PX G2, 9SX, and 9PX Lithium-ion UPS Systems. It is also used with various Eaton series including 5130, 5PX, 9135, Evolution, Evolution S, EX, MX, MX Frame, and EX RT as part of compatible configurations.
Q: What kind of software or workflows can I integrate with this interface?
A: You can integrate with server orchestration and management tools, building management systems (BMS), remote monitoring solutions, and automated shutdown scripts. The serial interface provides data and event signaling that can trigger scripts or alarms, while the relay output can drive external devices or signaling circuits.
Q: Are there any safety or regulatory certifications I should be aware of?
A: Yes. The card carries certifications including EN 61000-6-2 (immunity), EN 61000-6-3 (emission), EN 62040-2 (UPS safety), IEC/EN 60950-1 2002 (IT equipment safety), and CE marking, ensuring compliance with international standards and facilitating deployment in global facilities.
Q: Do I need professional installation, or can IT staff handle it?
A: For most standard deployments, IT staff with experience in UPS configuration and spare-part installation can install the card following the manufacturer’s guidance. Always follow safety procedures when working with powered equipment, and consult Eaton’s documentation if you are unsure about specific settings for your environment.
Customer reviews
Showing - Of Reviews