Description
The Eaton ePDU 1-Outlet 4.99kVA PDU is engineered for reliability, efficiency, and compact power distribution in modern data centers. Designed to fit in a standard 19-inch rack and clocking in at just 1U, this high-capacity power distribution unit delivers serious power to dense server racks while maintaining easy access, simple installation, and robust safety features. Ideal for edge deployments, lab environments, and enterprise data rooms, it provides a dependable, space-efficient solution for powering critical IT equipment with confidence.
- High-capacity, space-efficient design: With a 4.99kVA rating, this PDU efficiently supports high-demand servers and network gear in a compact 1U footprint, maximizing rack density without sacrificing reliability.
- Secure connectivity with NEMA L6-30R/L6-30P: Equipped with a locking NEMA L6-30R receptacle and a matching NEMA L6-30P plug, the PDU ensures secure, vibration-resistant power connections that stay in place under heavy equipment loads.
- Rack-mountable for standard 19-inch racks: The 1U form factor fits neatly into standard racks, making it an ideal choice for data centers seeking streamlined infrastructure and organized cabling.
- Simple, reliable power distribution: This Eaton ePDU provides clean, straightforward power delivery to connected devices, helping administrators manage power distribution efficiently across servers and network gear while reducing downtime risks.
- Durable construction and trusted engineering: Built with Eaton’s reputation for reliability, the 1-outlet 4.99kVA PDU is designed to withstand demanding data-center environments and deliver consistent performance over time.
Techncial Details of Eaton ePDU 1-Outlet 4.99kVA PDU
- Power rating: 4.99 kVA
- Outlet: 1 x NEMA L6-30R
- Input/Connector: NEMA L6-30P
- Mounting: 1U rack-mountable (fits standard 19-inch racks)
- Receptacle type: NEMA L6-30R for secure, locking connections
How to install Eaton ePDU 1-Outlet 4.99kVA PDU
Follow these straightforward steps to install the Eaton ePDU in a compatible 19-inch rack and begin powering critical equipment with confidence.
1) Prepare the rack space: Identify a clear, vibration-free area within the rack that will accommodate a 1U device. Ensure there is adequate clearance for the L6-30P input connector and the single L6-30R receptacle to permit easy cable routing and access.
2) Mount the PDU in the rack: Align the ePDU with the rack mounting rails and secure it using the provided hardware. Confirm the unit is level and firmly attached to prevent shifting when cables are connected or equipment is serviced.
3) Connect the input power: Use the NEMA L6-30P plug to connect the PDU to a compatible power source within your data center or enclosure. Ensure the power source is switched off during installation to maintain safety and prevent arcing.
4) Attach devices to the outlet: Connect your high-demand servers, network devices, or other critical gear to the single NEMA L6-30R outlet. Route cables neatly and employ cable management practices to minimize tension and avoid accidental disconnections.
5) Test and verify: Restore power and perform a basic power-on test to verify that the connected devices receive stable power. Check for any unusual heat, sounds, or voltage fluctuations and ensure all connections remain secure during normal operation.
6) Documentation and monitoring: Record the installation specifics, including input source and outlet usage, to support future maintenance and capacity planning. If you use Eaton’s broader power management ecosystem, consider integrating with monitoring software to track load and performance over time.
7) Safety and maintenance: Periodically inspect the connectors and wiring for signs of wear or loosening. Keep the area clean and free of debris to prevent interference with airflow and cooling in the rack environment.
Frequently asked questions
-
Q: What is the power rating of this Eaton ePDU?
A: The unit is rated at 4.99 kVA, providing substantial capacity for single-outlet power distribution in a 1U rack. -
Q: How many outlets does this PDU have?
A: It features a single NEMA L6-30R outlet (locking connection) for high-current needs. -
Q: What type of input plug does it use?
A: It uses a NEMA L6-30P input plug to connect to compatible power sources. -
Q: Is this PDU suitable for standard 19-inch racks?
A: Yes. The unit is designed to fit standard 19-inch racks in a 1U form factor, optimizing space in data centers and equipment closets. -
Q: Can this PDU be integrated with other Eaton power management products?
A: It is built to work within Eaton’s ecosystem, enabling straightforward integration with compatible monitoring and management solutions for improved visibility into load, capacity, and uptime.