Description
Unlock efficient, reliable power delivery for your IT equipment with the Eaton ePDU RCP200-GRY-LT. This compact, 2-outlet, 120 V AC horizontal power distribution unit combines precise active metering with dependable circuit protection, delivering up to 1440 W of dependable power through two NEMA 5-15R receptacles. Designed for 2U deployments, the RCP200-GRY-LT fits neatly into standard 19-inch racks, making it an ideal solution for small data centers, network closets, edge computing setups, and lab environments where space is at a premium but power reliability cannot be compromised. Whether you’re streamlining energy management in a busy office IT room or ensuring uptime for critical devices, this Eaton PDU provides the control, visibility, and protection you need to optimize operations and extend equipment life.
- Active metering for energy optimization. The RCP200-GRY-LT includes built-in metering that provides real-time visibility into voltage, current, and power consumption. This enables proactive energy management, helps identify undersized circuits before they trip, and supports cost-saving strategies by highlighting power usage patterns across your IT load.
- Two dependable NEMA 5-15R outlets. With two standard NEMA 5-15R receptacles, you can power a range of common IT devices, servers, networking gear, and peripheral equipment from a single, conveniently located PDU. The layout prioritizes easy access and organized cabling, reducing clutter in your rack space.
- Simple, safe power input. The PDU uses a NEMA 5-15P plug to connect to a 120 V AC power source, delivering a reliable, safe supply for typical office and data-center devices. The design emphasizes straightforward installation with minimal setup, so you can deploy quickly and stay focused on critical tasks.
- 2U, horizontal rack-mount form factor. Engineered for space-saving efficiency, this PDU fits in a standard 19-inch rack, occupying just 2U of rack height. Its horizontal orientation streamlines cable management, airflow, and accessibility for loading and servicing equipment in tight environments.
- Built-in protection and durable construction. The RCP200-GRY-LT is designed to safeguard your equipment with reliable circuit protection while delivering steady power output. Its rugged build supports continuous operation in professional IT spaces, helping minimize unexpected downtime and maintenance costs.
Technical Details of Eaton ePDU RCP200-GRY-LT
- Model: Eaton ePDU RCP200-GRY-LT
- Outlets: 2 x NEMA 5-15R
- Input plug: NEMA 5-15P
- Input voltage: 120 V AC
- Maximum power: 1440 W
- Form factor: 2U, horizontal PDU
- Metering: Active metering for energy optimization and circuit protection
- Receptacle type and usability: NEMA 5-15R outlets designed for maximum usability and reliable power output
how to install Eaton ePDU RCP200-GRY-LT
Installing the Eaton ePDU RCP200-GRY-LT is a straightforward process that fits seamlessly into most standard 19-inch racks. Before you begin, confirm that the rack space can accommodate a 2U device and that you have an appropriate power source available for a 120 V AC supply. Ensure you follow your facility’s electrical safety guidelines and any data-center or IT room policies related to rack-mounted equipment.
Step 1: Prepare the rack space. Identify a stable, accessible location within the rack where the PDU will be mounted. The 2U height allows it to sit alongside other equipment without obstructing airflow or service access. Clean the area to remove dust and secure any loose cables nearby to prevent interference during installation.
Step 2: Mount the PDU. Use the appropriate rack screws and rails to secure the PDU into the rack. Align the chassis with adjacent equipment to ensure clean cable management and easy access to the NEMA receptacles. Tighten fasteners evenly to avoid distortion and ensure the unit sits securely.
Step 3: Connect the input power. Insert the NEMA 5-15P plug into a properly rated 120 V AC power outlet or power strip that can support the expected load. Ensure the upstream circuit protection and breakers are rated for the anticipated maximum load. Do not exceed the PDU’s 1440 W rating to maintain safe operation and prevent nuisance trips.
Step 4: Connect your devices. Plug IT equipment into the two NEMA 5-15R outlets. Route cables neatly to minimize tangling and maximize airflow around equipment. If needed, label each outlet to simplify future power management and troubleshooting.
Step 5: Configure metering and verify operation. Power on the PDU and verify that the active metering readouts display correctly for voltage, current, and power. If your data-center infrastructure includes management software or a monitoring system, integrate the PDU’s data streams to enable centralized visibility, alerts, and reporting. Confirm that all connected devices are receiving power and that the total load remains within the safe operating range.
Step 6: Perform a light load test. Gradually apply load to the PDU by powering on connected devices and monitoring the metering data. Check for any signs of overheating, unusual noises, or voltage drops. If anomalies occur, power down safely and re-check connections before resuming operation.
Maintenance tip: Periodically review energy usage reports to identify opportunities for load balancing, consolidation, or redistribution of devices. Regularly inspect cables and outlets for wear, secure connections, and clean any dust buildup to maintain optimal performance.
Frequently asked questions
- Q: How many outlets does the Eaton ePDU RCP200-GRY-LT have? A: It features 2 x NEMA 5-15R outlets, suitable for common IT devices and network equipment.
- Q: What is the input voltage and maximum power? A: The PDU operates at 120 V AC with a maximum load of 1440 W, providing reliable power for standard office and data-center gear.
- Q: Does this PDU provide metering? A: Yes. The RCP200-GRY-LT includes active metering to monitor energy usage in real time, aiding energy optimization and circuit protection.
- Q: Is this PDU rack-mountable? A: Yes. It is designed as a 2U, horizontal PDU that fits in standard 19-inch racks for efficient space utilization and easy access.
- Q: What environments is this PDU suitable for? A: It is ideal for small to mid-size data centers, network closets, edge computing deployments, and lab environments where space is limited but reliable power delivery and monitoring are essential.