Description
Eaton FE 18kVA UPS with VRLA Batteries
Elevate your power protection with the Eaton FE 18kVA UPS, a reliable uninterruptible power supply engineered to safeguard critical equipment and maintain business continuity. Combining top-tier performance with competitive pricing, this UPS delivers consistent battery life and quality you can trust. Built around VRLA (valve-regulated lead-acid) technology, it offers robust backup for servers, networking gear, and industrial controls while minimizing maintenance requirements. With an 18 kVA capacity and clear, predictable runtimes—10 minutes at full load and 26 minutes at half load—the FE 18kVA ensures you have a dependable margin during outages, voltage sags, or transitions to standby power. The result is enhanced uptime, reduced risk, and peace of mind for IT rooms, data centers, manufacturing floors, and remote sites. Eaton’s commitment to performance and value is reflected in the battery design and engineering that prioritize long life, predictable delivery, and straightforward operation in a wide range of environments.
- High-capacity protection for critical loads: 18 kVA UPS power protection ensures continuous operation for servers, storage, networking, and other essential equipment, helping prevent data loss and downtime during outages or fluctuations.
- Defined runtimes for planning and reliability: 10 minutes of runtime at full load and 26 minutes at half load give you a clear buffer to safely shut down or switch to backup generation without disruption.
- VRLA battery technology for durability and low maintenance: Valve-regulated lead-acid batteries provide reliable performance with reduced maintenance needs, ideal for IT rooms and industrial environments.
- Rugged, space-conscious design: Engineered to fit typical data centers, IT closets, and mission-critical rooms, the FE 18kVA UPS combines solid construction with a compact footprint and quiet operation.
- Cost-effective, performance-driven battery solution: Eaton’s batteries are designed to deliver exceptional battery life and quality at a competitive price, helping protect your investment over time.
Technical Details of Eaton FE 18kVA UPS
- Capacity: 18 kVA
- Battery type: VRLA (Valve-Regulated Lead-Acid)
- Runtime at full load: 10 minutes
- Runtime at half load: 26 minutes
- Application: Uninterruptible power protection for critical IT, networking, and industrial equipment
How to install Eaton FE 18kVA UPS
Before you begin, review the product manual and local electrical codes. Plan the installation in a clean, well-ventilated space with adequate clearance for airflow and maintenance access. Ensure the UPS is placed on a stable surface and that the ambient temperature, humidity, and dust levels are within the manufacturer’s specifications.
1) Mount and position: Place the UPS in the designated equipment rack or on a solid, level surface with front accessibility for monitoring and maintenance. Allow sufficient space near the intake and exhaust to maintain proper ventilation.
2) Electrical connections: Connect the UPS input to the appropriate mains supply with proper grounding according to local codes. Attach the output to protected equipment such as servers, storage, and network gear. Use appropriate circuit protection per the manual.
3) Battery installation: Install the VRLA battery assembly(es) according to the manufacturer’s guidelines. Ensure all connectors are secure and that battery compartments are closed properly for safety and heat management.
4) Management and software: Connect any required management interfaces or software for monitoring, alerts, and graceful shutdowns. Configure alarms, load limits, and notification settings to align with your IT policies.
5) Commissioning and testing: Power up the system, perform a self-test as recommended by Eaton, and validate that the protected loads respond correctly to simulated outage conditions. Document the results for future reference and schedule routine maintenance checks.
6) Safety considerations: Always de-energize the circuit before accessing internal components, use appropriate personal protective equipment, and follow local safety protocols. Keep the area clean and free of obstructions to ensure reliable operation.
Frequently asked questions
- What is the runtime at full load? 10 minutes, enabling a controlled transition or safe shutdown of critical systems during short outages.
- What is the runtime at half load? 26 minutes, providing a larger window to bridge to generator start or to complete orderly shutdowns.
- What type of batteries does it use? VRLA (Valve-Regulated Lead-Acid) batteries, chosen for durability and low maintenance in long-life applications.
- Is the Eaton FE 18kVA UPS suitable for data centers? Yes. The 18 kVA UPS is designed to protect mission-critical IT equipment, servers, and networking gear commonly found in data centers and IT rooms, helping maintain uptime and data integrity.
- What maintenance is required? Regular battery health checks, periodic self-tests, and scheduled professional servicing through an authorized Eaton partner are recommended to ensure continued reliability and performance.