Eaton Flex PDU 1.92 kW max 110-125V 16A 12 Outlets 1U Single-Phase PDU

EatonSKU: 2507624

Price:
Sale price$166.42

Description

Two trends are shaping today’s data centers: devices are getting smaller and more power-dense, while other equipment still demands robust, reliable power delivery to keep mission-critical workloads humming. The Eaton Enclosure Power Distribution Unit (ePDU) line is purpose-built to meet both realities with elegance and ease. The Eaton Flex PDU, a compact 1U, 12-outlet solution, is crafted to maximize rack density without compromising on power quality or reliability. Designed for single-phase 110–125V environments, this architecture delivers up to 1.92 kW of continuous power from a single, tidy unit that fits neatly into standard 19-inch racks. Whether you are provisioning a micro-server cluster in a colocation cage, expanding a dense HPC node array, or equipping a lab rack with dependable power, the Eaton Flex PDU makes power distribution simpler, safer, and more scalable. It’s not just about plugging in devices; it’s about shaping a more organized, efficient, and resilient rack environment that lowers downtime risk and boosts operational efficiency.

  • 1U footprint with 12 outlets: The compact 1U form factor enables high-density rack deployments without sacrificing outlet count. With 12 easily accessible outlets, you can power multiple servers, switches, storage devices, and peripherals from a single, centralized source. The streamlined design reduces cable clutter and improves airflow, helping to maintain cooling efficiency across your rack. This configuration is ideal for modern data centers that need to pack maximum capability into limited rack space while keeping wiring organized and manageable.
  • High-density power, reliable performance: The Flex PDU supports a maximum of 1.92 kW at 110–125V with a 16A rating, giving you the clean, steady power distribution required for contemporary equipment footprints. This balance of power capacity and compact form helps keep circuits within safe limits while avoiding the risks of overloading. The result is consistent performance for blade servers, storage arrays, virtualization hosts, networking gear, and other density-focused assets that define today’s edge, core, and hybrid data centers.
  • Single-phase suitability for common data-center deployments: Built around standard 110–125V single-phase power, the Eaton Flex PDU is well suited to a wide array of configurations—from small labs to larger multi-rack installations. This compatibility ensures straightforward integration with existing electrical infrastructure and reduces the complexity of planning power for new racks. Whether your site relies on utility power or a backup generator feed, the PDU’s electrical characteristics align with typical data-center power rails to provide dependable, predictable distribution.
  • Durable, rack-ready design and cable-management benefits: The 1U enclosure is engineered for reliable operation in busy data-center environments. Its construction supports mounting in standard 19-inch racks with minimal footprint and straightforward cable routing. The design helps you organize power cables, shorten interconnect distances, and improve airflow, which can contribute to cooler equipment and lower cooling costs. With the Eaton brand behind it, you also gain the assurance of proven engineering, quality materials, and long-term serviceability that are hallmarks of enterprise-grade PDUs.
  • Flexible deployment and scalable power distribution: This PDU is part of a broader Eaton enclosure ecosystem, designed to adapt as your rack needs evolve. Start with a reliable 12-outlet, 1U unit and scale by adding additional PDUs for new racks, or reconfigure outlets to best match device counts and power budgets. The modularity and straightforward installation process reduce the time to provision new racks, accelerate maintenance, and support ongoing data-center expansion without requiring complex electrical rewiring.

Technical Details of Eaton Flex PDU

  • Power rating: Up to 1.92 kW (1U, 16A at 110–125V)
  • Voltage range: 110–125V AC
  • Current rating: 16A
  • Outlets: 12 outlets configured for standard rack-mount use
  • Form factor: 1U, rack-mountable enclosure
  • Phase: Single-phase distribution

How to install Eaton Flex PDU

  • Prepare the rack: Choose a suitable 19-inch rack with enough clearance for service access and adequate airflow. Ensure the rack is mounted on a stable surface and that the section you select has accessible power rails.
  • Mount the PDU: Slide the 1U Eaton Flex PDU into the selected rack space. Align mounting holes with the rack rails and secure the unit with the appropriate screws provided by your rack kit. Confirm that the unit is level and firmly fastened to prevent vibration or movement during operation.
  • Connect the input power: Attach the PDU’s input power cord to a suitable, protected power source that matches the 110–125V specification and 16A rating. Ensure that the circuit feeding the PDU can handle the combined load of all outlets to prevent tripping the breaker.
  • Route and organize cabling: Connect your servers, switches, and storage devices to the 12 outlets in an orderly fashion. Use cable-management features where possible to minimize tangling and to maintain proper airflow around the equipment. Label outlets if you manage multiple circuits or devices to simplify future maintenance.
  • Power on and verify: After all connections are secure, power on the PDU and the connected devices. Confirm that all connected equipment powers up as expected and monitor for any abnormal behavior. If you have additional monitoring or environmental sensors in your enclosure, verify that the PDU integrates smoothly with your monitoring stack.
  • Document and maintain: Record the rack, PDU position, and outlet assignments for future maintenance. Establish a routine for inspecting cables, checking for signs of wear, and updating labeling as racks scale or reconfigure. Regular checks help sustain performance and prolong the life of your power distribution setup.

Frequently asked questions

  • Q: What outlets are included on the Eaton Flex PDU?
  • A: The unit provides 12 outlets in a compact 1U form factor designed for standard 19-inch racks, suitable for powering servers, networking gear, and storage devices in a single distribution point.
  • Q: What is the maximum power this PDU can deliver?
  • A: Up to 1.92 kW (1.92 kilowatts) at 110–125V with a 16A rating, enabling efficient distribution for mid-range to dense rack configurations.
  • Q: Is this a single-phase PDU?
  • A: Yes. The Eaton Flex PDU is designed for single-phase power delivery in 110–125V environments, aligning with common data-center electrical infrastructure.
  • Q: Can I scale my power distribution by adding more PDUs to the same rack?
  • A: Yes. The 1U Flex PDU is compatible with standard rack layouts, and you can deploy additional PDUs in other rack positions or across multiple racks to meet evolving power budgets and density requirements.
  • Q: How does this PDU help with cable management and airflow?
  • A: The compact 1U footprint and 12-outlet layout reduce cable clutter and concentrate power distribution, supporting cleaner cable runs and improved airflow—key factors in maintaining equipment temperatures and cooling efficiency in busy data-center environments.
  • Q: Does it support remote monitoring or intelligent features?
  • A: This description covers the basic 1U PDU configuration. Some Eaton ePDU variants offer intelligent monitoring and remote management; for this specific 12-outlet, 1U model, verify the exact SKU to determine available monitoring options and management capabilities.