Eaton Internal Replacement Battery Cartridge (RBC) for 5P750 and 5P850G 5P UPS Systems

EatonSKU: 14209326

Price:
Sale price$178.59

Description

Eaton Internal Replacement Battery Cartridge (RBC) for 5P750 and 5P850G 5P UPS Systems

Ensure uninterrupted power for critical workloads with the Eaton Internal Replacement Battery Cartridge (RBC) designed specifically for the 5P750 and 5P850G 5P UPS systems. This OEM-compatible RBC provides a reliable, drop-in replacement for aging batteries, preserving backup readiness and minimizing downtime during battery refresh cycles. Built to meet Eaton’s stringent quality standards, the RBC delivers consistent performance, helping you protect sensitive data, maintain business continuities, and safeguard uptime across your IT, data center, and industrial environments. Whether you’re performing routine maintenance or refreshing aging units, this RBC is engineered to integrate seamlessly into your existing 5P UPS deployment, delivering the dependable power retention you rely on when mains power falters.

  • Precisely matched compatibility for 5P750 and 5P850G 5P UPS models ensures you receive a seamless, OEM-grade replacement that aligns with Eaton’s design and performance specifications to maximize runtime and reliability.
  • OEM-compatible construction uses quality cells and interconnects that replicate the original battery pack, delivering predictable discharge characteristics and consistent backup power when it matters most.
  • Fast, straightforward replacement with a pre-assembled cartridge design reduces maintenance downtime and supports a hassle-free swap during scheduled outages or emergency battery refreshes.
  • Extended service life and dependable uptime help lower total cost of ownership by maintaining robust backup capability and minimizing the risk of unexpected outages caused by degraded batteries.
  • Safety-conscious packaging and handling follows industry best practices for shipping and installation, helping protect personnel and equipment while ensuring regulatory compliance during replacement procedures.

Technical Details of Eaton Internal Replacement Battery Cartridge (RBC) for 5P750 and 5P850G 5P UPS Systems

Technical specifications are not provided in this listing. For exact details such as voltage, chemistry, capacity, physical dimensions, connectors, expected runtime, operating temperature range, and cycle life, please refer to the official Eaton RBC data sheet and the Synnex catalog entry using the product’s UPC or SKU. The RBC is designed to be fully compatible with the Eaton 5P750 and 5P850G models, delivering a reliable energy source to support safe shutdowns and sustained operation during power events. Always verify the precise SKU when ordering to ensure you receive the correct cartridge for your specific 5P UPS configuration.

Key considerations and typical specifications (conceptual)

While this listing does not enumerate the exact numeric specifications, the RBC generally encompasses the following categories that are central to its performance profile:

  • Voltage and chemistry consistent with OEM RBCs used by Eaton 5P UPS systems
  • Capacity designed to restore expected runtime at standard load conditions for the 5P750 and 5P850G deployments
  • Physical form factor and connector layout that matches the original cartridge for straightforward installation
  • Operating temperature range suitable for data centers and industrial environments
  • Recommended replacement interval aligned with Eaton maintenance guidelines and UPS usage patterns

How to Install Eaton RBC for 5P UPS

Installing the Eaton RBC is a straightforward process when performed by trained personnel following proper safety procedures. Below is a general, high-level guide to the replacement workflow. Always consult and adhere to the official Eaton installation manual for step-by-step instructions and any model-specific considerations.

Step 1: Prepare and safety-check Ensure the UPS is placed in a safe,well-ventilated area. Power down the system according to your facility’s procedures, and unplug the UPS from all power sources if required by your maintenance protocol. Wear appropriate personal protective equipment (PPE) and follow local safety regulations for handling battery packs and enclosed equipment.

Step 2: Access the RBC compartment Open the UPS cabinet following the manufacturer’s instructions. Locate the RBC compartment or battery module housing where the existing battery cartridge is installed. Confirm you are working with the correct 5P750 or 5P850G module to avoid compatibility issues.

Step 3: Remove the existing cartridge Carefully disconnect any interconnects or quick-release latches attached to the current battery cartridge. Lift the old RBC straight out of the deployment slot, avoiding tilting or bending delicate connectors. Place the cartridge on a non-conductive surface suitable for battery handling or into a containment for proper disposal per your facility’s battery recycling policies.

Step 4: Install the new RBC Inspect the new RBC for signs of damage before installation. Align the cartridge with the slot, seat it firmly, and reattach any connectors or latches. Ensure the cartridge is securely seated and that all protective seals or covers are properly engaged to prevent movement or arcing during operation.

Step 5: Restore power and validate Close the UPS cabinet and reconnect it to power sources according to your standard procedure. Power up the system and run a basic self-check or diagnostic test as outlined in the Eaton maintenance documentation. Monitor the UPS behavior to confirm that the RBC is recognized and that backup runtime aligns with expected specifications. If any alarms or abnormal readings occur, consult support resources and verify that the RBC is the correct SKU for your model.

Step 6: Documentation and disposal Record the replacement in your maintenance log, including date, asset tag, and the RBC SKU. Ensure proper disposal of the old battery cartridge in accordance with local regulations and your organization’s environmental policies.

Important safety notes: Handle battery cartridges with care to avoid short circuits or physical damage. Do not drop or strike the cartridge. Keep away from extreme temperatures and moisture. If you notice bulging, leakage, or unusual odors from any battery unit, discontinue use and follow your hazardous materials handling procedures immediately.

Frequently asked questions

Q: Is this RBC compatible with both the 5P750 and 5P850G UPS models?

A: Yes. This Eaton RBC is designed to be compatible with the Eaton 5P750 and 5P850G 5P UPS systems, providing a dependable replacement option that preserves original performance characteristics and backup capabilities.

Q: What are the advantages of replacing batteries with an OEM RBC?

A: OEM RBCs are engineered to match the original design, ensuring consistent discharge profiles, connector compatibility, and reliability. Replacing with an OEM cartridge helps maintain expected runtime, reduces the risk of unexpected UPS alarms, and supports long-term uptime for critical workloads.

Q: How long does an RBC replacement typically take?

A: Replacement duration varies by site procedure and personnel, but with a coordinated maintenance window and a trained technician, a cartridge swap can be completed within a short maintenance interval, often within an hour or less. This minimizes downtime and keeps critical systems online.

Q: Are there safety considerations or required PPE during replacement?

A: Yes. Handle all battery cartridges with care, use appropriate PPE (gloves, eye protection), and follow your organization’s safety policies. Ensure the UPS is de-energized per manufacturer guidance and that the work area complies with electrical safety standards. Proper disposal of old battery cartridges is essential and typically falls under hazardous waste regulations.

Q: Where can I verify the exact specifications for the RBC?

A: For precise technical specifications, refer to the official Eaton RBC data sheet or the Synnex catalog entry using the product’s UPC or SKU. This will provide the exact capacity, voltage, chemistry, dimensions, and expected runtime details necessary for your maintenance planning.